CAMPS SITE LEVEL MAINTENANCE MANUAL
…02…Issue 1…02…CAMPS
PROCESSOR UNIT TEST PROCEDURES STEP 1000-2000 (cont'd)
STEP PROCEDURE OBSERVATION/ACTION
̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
1734A/ktd/0237A…02…CPS/TCM/005
…02…KJA/830912…02……02…
CAMPS SITE LEVEL MAINTENANCE MANUAL
…02…Issue 1…02…CAMPS
4.3.3.1 P̲r̲o̲c̲e̲s̲s̲o̲r̲ ̲U̲n̲i̲t̲ ̲T̲e̲s̲t̲ ̲P̲r̲o̲c̲e̲d̲u̲r̲e̲s̲
* * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * * *
1000 PU TEST ENTRY
Before start of the PU test
procedure, verify that
1. The command typed on the
Maint.Pos.VDU is directed
to the PU which should
be tested.
2. The PU is offline.
3. The PU is enabled.
4. The PU is in Normal Mode.
It is possible to obtain these
conditions e̲i̲t̲h̲e̲r̲
a) by commands issued from
the Mint.Pos.VDU via the
Watch Dog Subsystem
o̲r̲
b) by manual switchs settings
on the MAP module and
a reconfiguration procedure.
a.1) P̲U̲ ̲-̲ ̲M̲a̲i̲n̲t̲.̲ ̲P̲o̲s̲.̲ ̲V̲D̲U̲ c̲o̲m̲m̲u̲n̲i̲c̲a̲t̲i̲o̲n̲
̲b̲y̲ ̲t̲h̲e̲ ̲W̲D̲ ̲c̲o̲m̲m̲a̲n̲d̲:
PUNno, no is No of the
actual PU.
(refer to setion 5.7.6
in (*))
a.2) P̲U̲ ̲o̲f̲f̲l̲i̲n̲e̲ ̲b̲y̲ ̲t̲h̲e̲ ̲W̲D̲ ̲c̲o̲m̲m̲a̲n̲d̲:̲
OFLI (refer to section
5.7.7 in (*))
a.3) P̲U̲ ̲e̲n̲a̲b̲l̲e̲d̲ ̲b̲y̲ ̲t̲h̲e̲ ̲W̲D̲ ̲c̲o̲m̲m̲a̲n̲d̲:̲
ENPU (refer to section
5.7.4 in (*)).
a.4) P̲U̲-̲n̲o̲r̲m̲a̲l̲ ̲m̲o̲d̲e̲ ̲t̲h̲e̲ ̲W̲D̲
̲c̲o̲m̲m̲a̲n̲d̲:̲ NORM (refer to
section 5.7.9 in (*)
(*) CAMPS MAINTENANCE POSITION
OPERATION MANUAL
DOC.No. CPS/OPM/005
b.1) P̲U̲-̲M̲a̲i̲n̲t̲.̲P̲o̲s̲.̲ ̲V̲D̲U̲ ̲c̲o̲m̲m̲u̲n̲i̲c̲a̲t̲i̲o̲n̲
b̲y̲ ̲r̲e̲c̲o̲n̲f̲i̲g̲u̲r̲a̲t̲i̲o̲n̲:̲
b.2) P̲U̲ ̲o̲f̲f̲l̲i̲n̲e̲ ̲b̲y̲ ̲s̲w̲i̲t̲c̲h̲s̲e̲t̲t̲i̲n̲g̲:̲
The PU is taken offline
by pressing the MC button
situated on the front
o the MAP module in the
actual PU (refer to section
4.5)
b.3) P̲U̲ ̲e̲n̲a̲b̲l̲e̲d̲ ̲b̲y̲ ̲s̲w̲i̲t̲c̲h̲s̲e̲t̲t̲i̲n̲g̲:̲
The PU is enabled by switching
the EN/DIS switch on the
front of the MAP module
in the actual PU to the
EN position (refer to
section 4.5)
b.4) P̲U̲ ̲ ̲N̲o̲r̲m̲ ̲M̲o̲d̲e̲ ̲b̲y̲ ̲s̲w̲i̲t̲c̲h̲s̲e̲t̲t̲i̲n̲g̲:̲
The PU is set in normal
mode by switching the
MAIN/NRM switch on the
front of the MAP module
to the NRM position. (refer
to section 4.5)
* * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * * *…86…1 …02… …02… …02… …02… …02…
1005 A Masterclear is o The
following
output
should
appear
issued by typing: after 5-10 sec.:
OC D[[[ [ (CR) "[7 MAP/BIT:OK"
"DAMOS BOOTLOADER VERSION.."
"CPU
""
If correct, continue to step
1010.
o If there is no coincidence
between the typed and the displayed
characters, or the expected
output does not appear, then
Reset the VDU by pressing the
CONTROL SHIFT and the LOAD
RESET key at the sae time.
Repeat step 1005
If the same error still appears
GO TO STEP 1200
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * *…86…1 …02… …02… …02… …02… …02…
1010 The PU configuration o The
following
output
should
appear:
is checked by typing:
UM (CR) See Figure 4.3.3.1-1
If correct, continue to step
1015
o If th configuration displayed
is not identical to the configuration
shown replace the RAM or STI
module (refer to Figure 4.3.3.1-1).
Repeat step 1010.
If the configuration displayed
is still not identically to
the configuration in figure
4.3.31-1, it is necessary to
check the PU crate.
Check the PU crate
GO TO step 1800.
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * *
1015 The CU configuration o The
following
output
should
appear:
is checked by typing:
UM1 CR) See Figure 4.3.3.1-2
If correct, continue to step
1035
o If it is not correct,GO TO
step 1020
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * *…86…1 …02… …02… …02… …02… …02…
PU UNIT MAPPING (UM)
Figure 4.3.3.1-1
CU Unit Mapping (UM1)
Figure 4.3.3.1-…86…1 …02… …02… …02… …02… …02…
1020 Assign the FD Ctrl o The
following
output
should
appear:
to the offline PU
by the Disk Assign- "FFFF"
ment command (refer " "
to the Maint. Pos.
Operation Manual) If correct, continue to step
1035.
or by the
CUCP switch which is
switched to the
offline PU.
Enable the FD Ctrl
by typing:
IR 1A[1 (CR)
o If the expected output does
not appear then it indicates
that it is not possible to
access the FDCtrl. Note this
and
GO TO step 1025.
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * *…86…1 …02… …02… …02… …02… …02…
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * *
*
*
* N̲O̲T̲E̲
*
*
*
* The SMD Disk Ctrl is taken offline
*
*
*
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * *
1025 ssign the Disk Ctrl o The
following
output
should
appear:
No. 2
to the offline PU "FFFF"
by the Disk Assign- " "
ment command (refer
to the Maint. Pos. If correct, GO TO step 1035
Operation Manual)
or by the
CUCP switch which is
switced to the
offline PU.
Enable the DISK Ctrl
by typing:
IR 1A25 (CR)
o If the expected output does
not appear
then it indicates that it is
not possible to access the
DISK Ctrl. Note this, and
GO TO step 1030.
* * * * * ** * * * * * * * * * * * * * * * * * * *
* * * * *…86…1 …02… …02… …02… …02… …02…
1030 Examine the
following situations:
o If it is not possible to access
either the FD Ctrl or the DISK
Ctrl, it indicates an error
in the connections between
the PU Crate an the CU Crate.
GO TO step 1805.
o If it is possible to access
the FD Ctrl but not the DISK
Ctrl, it indicates that it
is only possible to boot the
test programs via the FD Ctrl
connected to the FD. Note this
and
GO TO step 1035.
o I it is possible to access
the DISK Ctrl but not the FD
Ctrl, it indicates that it
is only possible to boot the
test programs via the DISK
Ctrl connected to the SMD disk
drive. Note this and
GO TO step 1035.
* * * * * * * * * * * * * * * * * * * * * * * * *
* * * * *…86…1 …02… …02… …02… …02… …02…
1035 It is now possible to o The
following
output
should
appear
boot the MAP test within 30 sec.
program.
A detailed step-by-
step boot and CSS/721 CR80 M MP TEST
activation com- VS ..."
mand procedure is "CPU ["
described in " ̲ ̲ ̲"
section 4.7.2.1
If correct, continue to step
1040
Below are listed
the main steps in
the boot procedure
of the MAP test.
Before entering the
boot command,
verify that:
The actual Disk or FD
Ctrl is assigned
to the Off-line PU.
(Ref. to the Main. Pos.
Opr. Man. CPS/OPM/005).
The actual disk pack
or diskette is
mounted in the
drive.
The FD boot comand
is as follows:
F̲D̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
BA 1[[1 (CR)
BT FD5[[ (CR)
BU [ or 1 (CR)
B̲E̲ ̲(̲C̲R̲)̲ ̲ ̲ ̲ ̲ ̲ ̲
The DISK boot
command is as
follows:
S̲M̲D̲ ̲D̲I̲S̲K̲
BA 1[25 (CR)
BM 14[ (CR)
B̲E̲ ̲5̲ ̲(̲C̲R̲)̲…86…1 …02… …02… …02… …02… …02…
o If the expected
output does not
appear then it
indicates that
is is not possible
to boot the test
program from that
drive.
Boot the MAP test
program using
the other flopp
drive or disk
drive.
If it is still
not possible to
boot the test
program, it indicates
an error in the
communication
between the Channel
Unit and the Processor
Unit.
GO TO step 2005.
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * *
1040 It is now possible o Examine the
output from
the test
to start the test program in order
to verify if
the
program. program detected
any errors.
A detailed step-by- The error codes
and an example
of a
step boot and ac- succe