top - download
⟦d56446bdd⟧ Wang Wps File
Length: 7565 (0x1d8d)
Types: Wang Wps File
Notes: CPS/TCM/024
Names: »3677A «
Derivation
└─⟦011bcd343⟧ Bits:30006160 8" Wang WCS floppy, CR 0242A
└─ ⟦this⟧ »3677A «
WangText
3677/rt…02…CPS/TCM/024
…02…LU/830907…02… #
CAMPS V24/V28 LOW-LEVEL ADAPTORS
…02…Issue 1…02…CAMPS
CAMPS V24/V28 LOW-LEVEL ADAPTORS Version
1
and
Version
2 Technical
Manual
(Peripheral Equipment Manual)
CPS/TCM/024 CDRL
Documentation
No.
03
Line Item No. 9.3
Leif Uldam
Kurt Nybroe-Nielsen
SHAPE (1), GJ, BHB, IJO, LT, LU, Conf. Mgm.,
QA.
PMS, KM, Library (5), GQAR
ILS Manager 830907
2
830907
…0f…Conf. Mgmt. 830907…0e…
3677A/rt …02…CPS/TCM/024
…02……0e…LU/830907…02……02…ii
CAMPS V24/V28 LOW-LEVEL ADAPTORS
(Peripheral Equipment Manual)…02…Issue 1…02…CAMPS…0f…
her inds`ttes first aid
3677A/rt …02… CPS/TCM/024
…02……0f…LU/830907…02……02…iii…0e…
CAMPS V24/V28 LOW-LEVEL ADAPTORS
(Peripheral Equipment Manual)…02……0f…Issue 1…02… CAMPS…0e…
830506 All Prelim.version of
the manual has
been changed
according to
SHAPE Review com-
ments as mentioned
in CPS Log. 970.
830907 All Issue 1 of the Manual
has been changed according
to SHAPE's comments
mentioned
in:
a) CPS Log No. 1047,
830128
b) CPS Log No. 1323,
830723
c) CPS Log No. 1365,
830902
3677A/rt …02…CPS/TCM/024
…02…LU/830907…02……02…iv
CAMPS V24/V28 LOW-LEVEL ADAPTORS…02…Issue 1…02…CAMPS
T̲A̲B̲L̲E̲ ̲O̲F̲ ̲C̲O̲N̲T̲E̲N̲T̲S̲
TITLE PAGE ....................................
i
FIRST AID FOR ELECTRICAL SHOCK .................
ii
REVISION RECORD ................................ iii
TABLE OF CONTENTS ..............................
iv
1. SCOPE ......................................
1
2. APPLICABLE DOCUMENTS .......................
2
3. CONTROLS AND SWITCHES ......................
3
4. APPLICATION ................................
4
5. LINE CONNECTIONS ...........................
5
6. ARC - MANUAL ...............................
14
1̲ ̲ ̲S̲C̲O̲P̲E̲
The ARC Manual is an OEM manual, which is grouped under
Peripheral Equipment Manuals in the CAMPS Documentation
Tree.
2̲ ̲ ̲A̲P̲P̲L̲I̲C̲A̲B̲L̲E̲ ̲D̲O̲C̲U̲M̲E̲N̲T̲S̲
1. CAMPS SITE LEVEL MAINTENANCE MANUAL
CPS/TCM/005
3̲ ̲ ̲C̲O̲N̲T̲R̲O̲L̲S̲ ̲A̲N̲D̲ ̲S̲W̲I̲T̲C̲H̲E̲S̲
Setting of Jumpers/Straps on the V24/V28 Low-Level
Adaptor for operation with the CAMPS is specified in
the CAMPS Site Level Maintenance Manual CPS/TCM/005,
Section 4.5 Controls and Indicators (4.5.5 Distribution
Equipment Subsystem):
T̲a̲b̲l̲e̲ ̲4̲.̲5̲.̲5̲-̲2̲ gives the Control/Indicator Function
of the 4-Channel Version.
The following figures gives the strap/jumper location
and setting for the mentioned application:
1: LTUX-S/PTR/P Interface
2: LTUX-S-TRC/ Point-to-Point Interface
3: REMOTE TERMINALS/STAT.MUX-OCR Interface
4: REMOTE TERMINALS/STAT.MUX-VDU/MSP Interface (Electronic
I/F)
T̲a̲b̲l̲e̲ ̲4̲.̲5̲.̲5̲-̲3̲ gives the Control/Indicator Function
of the 1-Channel Version. The following figures gives
the Strap/Jumper locations and setting for the mentioned
application:
1: LTU/SCARSII/ACCIS Interface
2: LTU/COLLOCATED TARE Interface
3: LTU/REMOTE TARE Interface
4: LTUX-S/OCR Interface
4 A̲P̲P̲L̲I̲C̲A̲T̲I̲O̲N̲
Section 4 APPLICATION in the ARC-Manual gives a description
of the general application of the V24/V28 Low-Level
Adaptor Module.
The specific application is described in the following:
To minimize cable emission when data is transferred
from the LTUX-S modules to the distribution equipment
(VDUs, MSPs, etc), the standard V24/V28 voltage levels
of +/-12V are reduced to +/-6V. Also the wave shape
of the signals are changed (slopes are flattened) to
reduce harmonic generation.
Two types of the V24/V28 L/L Adaptors are connected
to the LTUX-S channels:
T̲Y̲P̲E̲ ̲1̲: Transfers the V24 signals of 4 channels of
1200 baud.
By means of straps, the actual application is selected.
T̲Y̲P̲E̲ ̲2̲: Transfers the V24 signals of 1 channel (OCR
connection, Main Site). By means of straps the actual
application is selected.
The V24/V28 L/L Adaptor Module is supplied from a separate
18V AC Power supply in the CTX-crate.
Rectifiers and regulators on the V24/V28 L/L Adaptor
Module provide the DC voltages of +5V, +/-12V.
5 L̲I̲N̲E̲ ̲C̲O̲N̲N̲E̲C̲T̲I̲O̲N̲S̲
The following pages give the line connections used
with the CAMPS V24/V28 Low-Level Adaptor.
4̲-̲c̲h̲a̲n̲n̲e̲l̲ ̲v̲e̲r̲s̲i̲o̲n̲:
1: LTUX-S/PTR/P Interface
2: LTUX-S-TRC/ Point-to-Point Interface
3: REMOTE TERMINALS/STAT.MUX-OCR Interface
4: REMOTE TERMINALS/STAT.MUX-VDU/MSP Interface
(Electronic I/F)
1̲-̲c̲h̲a̲n̲n̲e̲l̲ ̲v̲e̲r̲s̲i̲o̲n̲
1: LTU/SCARSII/ACCIS Interface
2: LTU/COLLOCATED TARE Interface
3: LTU/REMOTE TARE Interface
4: LTUX-S/OCR Interface
Figure 5-1…01…LTUX-S/PTP-PTR INTERFACE
Figure 5-2…01…LTUX-S-TRC/Point-to Point Interface
Figure 5-3…01…Remote Terminals STAT.MUX. - OCR Interface
Figure 5-4…01…Remote Terminals STAT.MUX. - VDU/MSP Interface…01…(Electric)
Figure 5-5…01…LTU/SCARSII/ACCIS Interface
Figure 5-6…01…LTU/Collocated Tare Interface
Figure 5-7…01…LTU/Remote Tare Interface
Figure 5-8…01…LTUX-S/OCR Interface
4̲ ̲ ̲A̲R̲C̲ ̲V̲2̲4̲/̲V̲2̲8̲ ̲L̲O̲W̲-̲L̲E̲V̲E̲L̲ ̲A̲D̲A̲P̲T̲O̲R̲…01…U̲S̲E̲R̲S̲ ̲M̲A̲N̲U̲A̲L̲
Document No.: ARC AP-7466-99-002,
Issue: 1
Date: 2/24/83
(The ARC-Manual is included in the following).