DataMuseum.dk

Presents historical artifacts from the history of:

CR80 Wang WCS documentation floppies

This is an automatic "excavation" of a thematic subset of
artifacts from Datamuseum.dk's BitArchive.

See our Wiki for more about CR80 Wang WCS documentation floppies

Excavated with: AutoArchaeologist - Free & Open Source Software.


top - download

⟦d781a915e⟧ Wang Wps File

    Length: 5558 (0x15b6)
    Types: Wang Wps File
    Notes: Channel Unit Control Pane 
    Names: »1435A «

Derivation

└─⟦0f7ba544d⟧ Bits:30006063 8" Wang WCS floppy, CR 0095A
    └─ ⟦this⟧ »1435A « 

WangText




…02…CPS/ECP/017

…02…SRA/811111…02……02…#
CHANNEL
 UNIT CONTROL
 PANEL
…02……02…CAMPS








                     1̲.̲ ̲ ̲I̲N̲T̲R̲O̲D̲U̲C̲T̲I̲O̲N̲



         This ECP is issued to introduce a Channel Unit Control
         Panel (CUCP), which provides the possibility of manually
         overriding certain Watchdog signals for maintenance
         and diagnostics purposes.

         The Channel Unit contains I/O controllers, which are
         all connected electrically to both Data Bus A and Data
         Bus B, but only assigned to one of these.  The assignment
         is a result of a "Take Ownership" command issued by
         one of the connected PUs.

         To prevent unintended I/O controller claims in case
         of PU-failure, the Watchdog is able to disable one
         of the bus interfaces on all the I/O controllers in
         the Channel Unit.  As a supplement to the Watchdog
         control, the CUCP provides the possibility of manually
         disabling the buses, which is necessary in case of
         Watchdog failure.

         Furthermore, the CUCP is able to override the disable
         signals for single I/O-Controllers, which is helpful
         when off-line maintenance and diagnostics programs
         are executed.









                2̲.̲ ̲ ̲F̲U̲N̲C̲T̲I̲O̲N̲A̲L̲ ̲D̲E̲S̲C̲R̲I̲P̲T̲I̲O̲N̲



         The CUCP is a front module, which controls the bus
         disable inputs of a number of I/O-controllers in a
         Channel Unit (ref. fig. 2-1).

         The state of the resulting disable signals is based
         on both the Watchdog disable signals and the setting
         of a number of switches on the front panel.

         The disable principle is shown in fig. 2-2.

















































                         Fig. 2-1






















         The signals marked "*" are controlled by switches on
         the CUCP front panel.



         NOTE:  "ALLOW ENABLE (A)" and "ALLOW ENABLE (B)" can
         not both be active at the same time.




















                         Fig. 2-2


2.1      I̲/̲O̲-̲C̲O̲N̲T̲R̲O̲L̲L̲E̲R̲ ̲I̲/̲F̲

         The CUCP is able to control:

         3 DISK CONTROLLERS

         5 LTUs (CAMPS Max. is 4 LTUs in one CU)

         1 FLOPPY DISK CONTROLLER

         The control and status signals on the I/O-controllers,
         which are applicable are listed below:

         EAD(L):     External A-bus Disable

         EBD(L):     External B-bus Disable

         ASEL(L):    A-bus Selected

         BSEL(L):    B-bus Selected



2.2      W̲A̲T̲C̲H̲D̲O̲G̲/̲C̲C̲A̲ ̲I̲/̲F̲

         The Watchdog control and status signals from/to the
         CCA are the following:

         DEV3(L):    Disable A-bus

         DEV4(L):    Disable B-bus

         M1(L):      Take Ownership Auto



2.3      C̲U̲C̲P̲

         The layout of the CUCP front panel is divided into
         two groups:

         a)  Overall control area

         b)  9 individual control areas



         a)  The features of the overall control area are (ref.
             fig. 2.3-3):

             1)  AUTO CONTROL

             2)  DIS (CU BUS A)

             3)  AUTO (CU BUS A)

             4)  DIS/AUTO switch (CU BUS A)
             
             5)  DIS (CU BUS B)
                 Bus B equivalent to 2.

             6)  AUTO (CU BUS B)
                 Bus B equivalent to 3.

             7)  DIS/AUTO Switch (CU BUS B) Bus B equivalent
                 to 4.

             The control principle is shown in Fig. 2.3-1


















































                        Fig. 2.3-1


         b)  I̲n̲d̲i̲v̲i̲d̲u̲a̲l̲ ̲C̲o̲n̲t̲r̲o̲l̲ ̲A̲r̲e̲a̲s̲

             Each of the 9 control areas comprises the following
             functions (ref. fig. 2.3-3):

             8)  BUS A

             9)  BUS B

            10)  Switch
                 AAEN (A-Allow enable):
                 Both Watchdog and CUCP disable of bus A are
                 inhibited.

                 BAEN (B-Allow enable):
                 Both Watchdog and CUCP disable of bus B are
                 inhibited.

                 AUTO:
                 No individual CUCP interference.

         The individual control principle is shown in fig. 2.3-2.



















































                        Fig. 2.3-2

















































                        Fig. 2.3-3


2.4      P̲O̲W̲E̲R̲ ̲S̲U̲P̲P̲L̲Y̲

         The CUCP is supplied from both bus A and bus B in order
         to maintain operation in case of power failure on one
         of the buses.

         The power lines are combined in an OR-circuit, which
         also incorporates a current limiter function in order
         to protect the power system against module short circuits.









                  3̲.̲ ̲ ̲C̲U̲C̲P̲ ̲I̲N̲S̲T̲A̲L̲L̲A̲T̲I̲O̲N̲



         When the CUCP is installed in one of positions 7 to
         21 of the front crate, a number of signal cables have
         to be connected to the J3-connector.

         a)  Each I/O-controller is connected by 6 wires to
             the CUCP.

         b)  DEV3(L) and DEV4(L) from CCA are connected to the
             CUCP by 4 wires.

         c)  M1(L) from CCA is connected to the CUCP by 2 wires.

         The installation principle is shown in fig. 3-1.


















































                         Fig. 3-1


              4̲.̲ ̲ ̲E̲L̲E̲C̲T̲R̲I̲C̲A̲L̲ ̲S̲P̲E̲C̲I̲F̲I̲C̲A̲T̲I̲O̲N̲S̲



         a)  The M1(L)-output is specified as follows:

             Active:   V…0f…0…0e…   9V, I…0f…0…0e…    3 mA

             Passive:  V…0f…0…0e…   3V, I…0f…0…0e…   15 mA

             All other outputs are equivalent to LS-TTL drivers.

         b)  All inputs load with the equivalent of one LS-TTL
             input.

         c)  Power consumption:

               5V:   I…0f…L…0e…    0,8 A

             +12V    I…0f…L…0e…   30 mA

             -12V:   I…0f…L…0e… =  0 A


              5̲.̲ ̲ ̲M̲E̲C̲H̲A̲N̲I̲C̲A̲L̲ ̲S̲P̲E̲C̲I̲F̲I̲C̲A̲T̲I̲O̲N̲S̲




































             H:  412.6 mm

             W:  3M   51.4 mm

             D:  305 mm