⟦d84987945⟧ Wang Wps File

    Length: 5133 (0x140d)
    Types: Wang Wps File
    Notes: CPS WATCHDOG, REQ. REVIEW 
    Names: »0416A «

Derivation

└─⟦74b766e5b⟧ Bits:30006076 8" Wang WCS floppy, CR 0033A
    └─ ⟦this⟧ »0416A « 

WangText




…02…

…02…BHB/801215…02……02…#
CAMPS WATCHDOG, REQUIREMENT REVIEW
…02……02…CAMPS








                  MINUTES OF MEETING, 801205



             Participants: GB, TK, OE, FC, SRA, FH, BHB, BHJ, SVO,
             LP

             Copy to:      GJ, JPR, FAH, FE, KNN



1            The CAMPS WATCHDOG DESIGN NOTE (CPS/TCN/017) was reviewed.
             Attached to these minutes is a new edition of CPS/TCN/017
             revised as per:

             a)  Appendix to CPS/TCN/017 (BHB/801126)

             b)  Agreed changes at review meeting

             The changes are marked.

             Figures will be changed, when action items are closed.



2            N̲o̲t̲e̲s̲ ̲a̲n̲d̲ ̲A̲c̲t̲i̲o̲n̲ ̲I̲t̲e̲m̲s̲ ̲(̲r̲e̲f̲.̲ ̲t̲o̲ ̲C̲P̲S̲/̲T̲C̲N̲/̲0̲1̲7̲)̲



2.1          R̲e̲f̲.̲ ̲F̲i̲g̲.̲ ̲1̲.̲1̲

FH Action    The feasibility of operating the Floppy disk by the
             
(due 12/12)  VDU connected to the WD shall be investigated.



2.2          R̲e̲f̲.̲ ̲F̲i̲g̲.̲ ̲1̲.̲1̲

             The Watch Dog panel controller is not used as all switch-operation
             performed via the CCIS has back-up switches in the
             crates.

             This back-up strategy was accepted and the implementations
             are discussed below.





2.3          R̲e̲f̲.̲ ̲1̲.̲1̲.̲2̲ ̲b̲)̲

             Comments to manually operated Initial Bite (IBITE):



2.3.1        P̲U̲

             Master Clear is activated by switch on MAP-module (conditioned
             "Maintenance mode" switch is activated.



2.3.2        C̲U̲

             Due to the dualized bus of the CU, a general master
             clear for all modules in the crate is not applicable.

             A command for initialization is given to individual
             modules of the CU by the I/O-Bus. The modules will
             then perform IBITE.

             IBITE is performed on power up as well.

2.3.3        T̲D̲X̲-̲C̲r̲a̲t̲e̲s̲

             TK informed us that TDX-ctrl and LTUX-S had no implemented
             IBITE-procedure by now, but the modules were prepared
             for IBITE.

             The IBITE can be activated in two ways:

             a)  By power-up

             b)  By command via the Bus
GB confirms
action (due  It is a requirement for CAMPS that the IBITE is
15/12)       implemented on TDX CTRL and LTUX-S.



2.4          R̲e̲f̲.̲ ̲3̲.̲3̲.̲1̲ ̲D̲

             Wired-or monitoring are not included in recent de-
GB action    sign. GB supplies the functional specification of
(due 15/12)  the "Power-up-procedure" to CAMPS. The discussions
             on the monitoring concept will then be concluded.





2.5          R̲e̲f̲ ̲3̲.̲2̲



2.5.1        CAMPS team emphasized the requirement for the abili-
FC action    ty to switch off the CU-modules, individually by 
(summarize   manually operated switch.
functional
reasoning)
(due 15/12)

GB action    GB supplies specifications for "disable-concept" in
(due 15/12)  order to conclude discussion.



2.5.2        GB informed us that the ownership LED's was included
             in recent design.



2.5.3        GB informed us that each CIA performs a power voltage
             supervision. When the Power supply of the bas is below
             a threshold, the CIA closes the bus and indicates the
             status to the PU.



2.6          R̲e̲f̲.̲ ̲3̲.̲3̲



2.6.1        TK informed us that the 5 TDX-ctrl status monitor signals
             are not supported by recent standard ctrl firmware.
             They are implemented in H/W as general
GB checks    output parts, and might be used as a part of the
(due 12/12)  application.



2.6.2        IBITE can be activated by switching the power of the
             TDX-crate off/on.





2.6.3        LEDs are provided on the front panels of TDX-CTRL
GB checks    and LTUX-S to monitor IBITE-performance.
(due 15/12)



2.7          R̲e̲f̲.̲ ̲3̲.̲4̲



2.7.1        GB will produce a preventive maintenance concept
GB action    for 80D-Blower. The possibilities and needs for Blo-
(due 15/12)  wer supervision via WD will then be concluded.



2.7.2        It is a CAMPS requirement (CPS/210/SYS/001, sect. 3.4.3.1)
             that "an alarm indication will be given, where the
             environmental temperature reaches a value, which will
             require intervention of supervisory personnel."

BHB Action   An input on the CCA's of the 80D-crates may be reserved
             for thermo-switch input. This will be specified dependent
             of Blower supervision concept.



2.8          Product spec. for WD will be released prior to 
GB Action    1/1-81.



2.9          S̲w̲i̲t̲c̲h̲e̲s̲



2.9.1        R̲e̲f̲ ̲3̲.̲1̲ ̲(̲P̲U̲)̲

             a)  Maintenance mode switch is on MAP-front panel

             b)  Master clear switch is on MAP front panel

GB Action    c)  Disconnect PU in MIA/TIA. Switch for manual
(due 15/12)      operation on which module?

GB Action    d)  Indications for "Manual" transmitted to WD (a)
(due 15/12)      and (c) above. GB provides concept.


2.9.2        R̲e̲f̲ ̲3̲.̲2̲ ̲(̲C̲U̲)̲

             a)  Bus disable switches, see section 2.5 above.

GB Action    b)  Indication for "Manual" from switches on a) 
(due 15/12)      above.



2.10         P̲U̲ ̲P̲o̲w̲e̲r̲ ̲S̲u̲p̲e̲r̲v̲i̲s̲i̲o̲n̲

             GB informed us that a "power-failure-interrupt" is
             provided in the PU, when DC-power-levels are below
             detector thresholds.

             The interrupt may be used for "controlled power down".



2.11         The LTU used in the WD is exact the same type as normal
             LTUs.



2.12         Connection of CCB to WD. GB checks that CCB is designed
             for connection to connector on WCA-front panel.



2.13         R̲e̲f̲.̲ ̲4̲.̲1̲

GB checks    Communication speed at min 9.6 Kbits
(due 15/12)



3            The contents of sect. 4 was not fully discussed at
             the meeting.