…02…CPS/ECP/022

…02…SRA/820421…02……02…#
CHANGE OF LTUX-S FIRMWARE TYPES
…02……02…CAMPS








         To:     GJ, KNN, BHB, MBJ, CGR, HKI, KPL, SL
         From:   SRA

         Subject:    L̲T̲U̲X̲-̲S̲ ̲r̲e̲l̲e̲a̲s̲e̲ ̲1̲ ̲f̲i̲r̲m̲w̲a̲r̲e̲ ̲f̲o̲r̲ ̲t̲h̲e̲ ̲D̲S̲M̲T̲
                     ̲H̲/̲W̲ A̲C̲C̲E̲P̲T̲A̲N̲C̲E̲ ̲T̲E̲S̲T̲.̲

         Ref.:       Meeting 820420, participants: KNN, KPL,
                     HKI, SL, SRA, CGR

         On the referenced meeting following was aggreed:

         1)  Upon power up the LTUX-S opens LOG. channels 2-5
             towards either Host no. 1 or Host no. 2. The Host
             no. to be used is set on the user switch on the
             LTUX-S. This switch consists of 4 single switches
             of which only switch 1 is used. The switch is read
             from I/O address #E0 with switch 1 reflected in
             databit 3. Host no. 1 shall be selected if this
             bit equals …08…0…08… and no. 2 is selected if the bit equals
             …08…1…08….

         2)  The LTUX-S shall act completely transparrent to
             data transmitted from CR80 to a connected terminal.
             LDU headers shall be stripped from the raw data.

         3)  When receiving from a connected terminal the LTUX-S
             shall consider a DC3 (#13) character as the terminating
             character. The DC3 shall not be transmitted towards
             CR80. The LTUX-S shall insert the correct LDU headers.

         4)  The present design with 32 bytes buffers on the
             LTUX-S is maintained.

         5)  The present V24 driver design with …08…NULL…08… characters
             transmitted is maintained since the …08…NULL…08… characters
             will not affect the VDU or MSP.



1        I̲N̲T̲R̲O̲D̲U̲C̲T̲I̲O̲N̲

         It is proposed to establish a new baseline for LTUX-S
         firmware types:

BASELINE       1            2           3
          PROPOSAL    SDS/RSPL     NEW PROPOSED
                                    811215
----------------------------------------------------
          OPTO  L/L-  OPTO  L/L-   OPTO   L/L-
          I/F   I/F   I/F   I/F    I/F    I/F
VDU       Type        Type         Type
            1           1            1
MSP       Type        Type         Type
            1           1            2
PTP/R           Type        Type          Type
                  1           1             2
LSM             Type        Type          Type
                  2           2             2
OCR             Type        Type          Type
                  3           3             3
----------------------------------------------------


         References: CPS/007/PRO/0002, II, 2,C (PROPOSAL)
                     CPS/SDS/001, issue 1.2
                     SHAPE TELEX, CAMPS LOG NO. 264
                     PMOM NO. 9, sect. 40

1.1      E̲Q̲U̲I̲P̲M̲E̲N̲T̲ ̲M̲A̲T̲R̲I̲X̲ ̲C̲H̲A̲N̲G̲E̲S̲

         When the firmware baseline is changed, the equipment
         matrix needs to be updated according to the combined
         connectivity tables for MAIN CAMPS and CAMPS REMOTE
         TERMINALS.

         The following principles are applied:

         a)  VDU and MSP channels are not supported from the
             same LTUX-S.

         b)  Connected capacity is unchanged

         c)  Equipped capacity is not decreased

         d)  If the equipped capacity is increased, the wired
             capacity is decreased accordingly.


2        P̲R̲I̲C̲E̲ ̲Q̲U̲O̲T̲A̲T̲I̲O̲N̲

         The ECP 22 is a non cost ECP.

2.1      O̲V̲E̲R̲A̲L̲L̲ ̲R̲E̲Q̲U̲I̲R̲E̲M̲E̲N̲T̲

         Not applicable.

2.2      S̲I̲T̲E̲ ̲R̲E̲L̲A̲T̲E̲D̲ ̲C̲O̲S̲T̲S̲

         Not applicable.

2.3      C̲U̲R̲R̲E̲N̲T̲ ̲B̲A̲S̲E̲L̲I̲N̲E̲ ̲C̲O̲S̲T̲

         Not applicable.

3        S̲C̲H̲E̲D̲U̲L̲E̲ ̲I̲M̲P̲A̲C̲T̲

         If the ECP is accepted prior to 820510, no schedule
         impact is expected.

4        B̲I̲D̲D̲I̲N̲G̲ ̲P̲R̲O̲V̲I̲S̲I̲O̲N̲S̲

         Not applicable (non cost ECP).

4.1      V̲A̲L̲I̲D̲I̲T̲Y̲

         Not applicable.

4.2      D̲E̲L̲I̲V̲E̲R̲Y̲

         The changed firmware will be included in the LTUX-Ss
         and delivered with each Main Site Equipment.

4.3      A̲C̲C̲E̲P̲T̲A̲N̲C̲E̲ ̲C̲R̲I̲T̲E̲R̲I̲A̲

         Will be included in Main CAMPS acceptance as described
         in CAMPS SRS, CPS/210/SYS/0001 and CAMPS ACCEPTANCE
         PLAN, CPS/PLN/012.

4.4      T̲Y̲P̲E̲ ̲O̲F̲ ̲P̲R̲O̲P̲O̲S̲A̲L̲

         Non cost ECP.

4.5      P̲A̲Y̲M̲E̲N̲T̲ ̲P̲L̲A̲N̲

         Not applicable.



4.6      P̲R̲O̲T̲E̲C̲T̲I̲O̲N̲ ̲A̲G̲A̲I̲N̲S̲T̲ ̲C̲U̲R̲R̲E̲N̲C̲Y̲ ̲F̲L̲U̲C̲T̲U̲A̲T̲I̲O̲N̲

         Not applicable.

5        E̲N̲G̲I̲N̲E̲E̲R̲I̲N̲G̲ ̲C̲H̲A̲N̲G̲E̲ ̲D̲E̲S̲C̲R̲I̲P̲T̲I̲O̲N̲

         Refer to section 1 for general description of the proposed
         change.
         Appendix A gives a few examples of changes in the connectivity
         matrix (CPS/SDS/001).


























                        A̲P̲P̲E̲N̲D̲I̲X̲ ̲A̲




















































            SITE 2 BALTAP (ONE REMOTE STATION)
              OLD BASELINE, LTUX-S FIRMWARE



















































            SITE 2 BALTAP (ONE REMOTE STATION)
              NEW BASELINE, LTUX-S FIRMWARE



















































          SITE 5 BOERFINK (TWO REMOTE STATIONS)
              OLD BASELINE, LTUX-S FIRMWARE



















































          SITE 5 BOERFINK (TWO REMOTE STATIONS)
              NEW BASELINE, LTUX-S FIRMWARE



















































           SITE 8 KOLSAAS (ONE REMOTE STATION)
              OLD BASELINE, LTUX-S FIRMWARE



















































           SITE 8 KOLSAAS (ONE REMOTE STATION)
              NEW BASELINE, LTUX-S FIRMWARE