⟦d97fbc2d8⟧ Wang Wps File

    Length: 4324 (0x10e4)
    Types: Wang Wps File
    Notes: Spelunked
    Names: »~ORPHAN47.08«

Derivation

└─⟦af82dd301⟧ Bits:30006082 8" Wang WCS floppy, CR 0127A
    └─ ⟦this⟧ »~ORPHAN47.08« 

WangText

er profile.

 Each subprocess has a list of capabilities, the capability array.


         The capability array defines which queues the subprocess
         can access and the set of QMON functions the subprocess
         can perform on each of these queues.

         The subprocess has only accss to a queue if it is represented
         by a capability in the capability array of the subprocess.

         Two capability arrays are defined in connection with
         subprocesses.

         -   for each entry in the queue capability array is
             specified a capability function msk, which specifies
             which QMON functions the subprocess can perform
             on the associated queue.

         -   for each subprocess is specified a function mask
             (in the subprocess attributes).  The mask specifies
             which privileged CSF functions the subprocess may
             all.



2.2.2.6.4    P̲r̲e̲s̲e̲n̲t̲a̲t̲i̲o̲n̲ ̲o̲f̲ ̲M̲e̲s̲s̲a̲g̲e̲s̲

         The SSC handles

         -   security interrogation

         -   security warning

         related to presentation of messages.
















figure…86…1         …02…   …02…   …02…   …02…                                          
 
2.3      C̲H̲A̲R̲A̲C̲T̲E̲R̲I̲S̲T̲I̲C̲S̲



2.3.1    T̲i̲m̲i̲n̲g̲



2.3.1.1  S̲w̲i̲t̲c̲h̲o̲v̲e̲r̲

         A switchover is to be performed within 60 seconds.



2.3.1.2  I̲n̲i̲t̲i̲a̲l̲i̲z̲a̲t̲i̲o̲n̲

         Initialization is to be performed within 5 minutes.



2.3.1.3  R̲e̲c̲o̲v̲e̲r̲y̲/̲R̲e̲s̲t̲a̲r̲t̲

         Recovery/restart subsequent to a total system failure
         is to be performed within 15 minutes.



2.3.1.4  W̲a̲t̲c̲h̲d̲o̲g̲ ̲L̲i̲n̲e̲ ̲S̲p̲e̲e̲d̲s̲

         The watchdog shall support the following line speeds:

         -   to PUs: 9.6 K Baud

         -   o operator ROP: 2400 Band

         -   to operator VDU: 2400 Band…86…1         …02…   …02…   …02…   …02… 
                                                      
2.3.1.5  R̲e̲s̲p̲o̲n̲s̲e̲ ̲T̲i̲m̲e̲

         The response time for user procedures is defined in
         section 3.4.1.6.3 in the CAMPS System Requirements
         CPS/210/SYS/0001.

         The response time for supervisorycommands is defined
         in section 3.4.1.6.5 in the CAMPS System Requirements
         CPS/210/SYS/0001.



2.3.1.6  S̲t̲a̲r̲t̲-̲U̲p̲ ̲a̲n̲d̲ ̲C̲l̲o̲s̲e̲-̲D̲o̲w̲n̲ ̲S̲e̲q̲u̲e̲n̲c̲e̲

         CAMPS software components are started/closed in a specific
         sequence, which is defined in section 4. Generally
         erminal and traffic handling packages are started latest/closed
         first, whereas service software e.g. log, statistics
         are started first/closed latest.



2.3.1.7  P̲r̲i̲o̲r̲i̲t̲i̲e̲s̲ ̲o̲f̲ ̲I̲n̲p̲u̲t̲

         No specific prioritizing exists.



2.3.2    T̲h̲r̲o̲u̲g̲h̲p̲u̲t̲



2.3.2.1  I̲c̲r̲e̲a̲s̲e̲ ̲o̲f̲ ̲S̲o̲f̲t̲w̲a̲r̲e̲ ̲S̲i̲z̲e̲

         Application software are designed to have a capacity
         to allow for a 10 per cent increase in object code????????



2.3.2.2  E̲q̲u̲i̲p̲m̲e̲n̲t̲ ̲C̲a̲p̲a̲c̲i̲t̲y̲

         The SSC software allows operation of equipment corresponding
         to wired capacity.

         Via operator commands an equipment can be brought into/out
         of operatinal use.



2.3.3    F̲l̲e̲x̲i̲b̲i̲l̲i̲t̲y̲



2.3.3.1  H̲a̲r̲d̲w̲a̲r̲e̲ ̲C̲o̲n̲f̲i̲g̲u̲r̲a̲t̲i̲o̲n̲ ̲C̲h̲a̲n̲g̲e̲s̲

         The system is designed to be able to handle the wired
         capacity configuration.

         Expansion beyond this maximum

         -   May require auxiliary PU capacity

         -   Requires software regeeration

         The actual configuration control is mainly table driven.



2.3.3.2  O̲p̲e̲r̲a̲t̲o̲r̲ ̲C̲o̲m̲m̲a̲n̲d̲s̲

         Changes in operator formats (except for field contents)
         can be performed by changing an appropriate format
         on the initialization disk.

         New formats o changes in field contents in existing
         formats require inclusion of new procedures, which
         syntax/semantic checks the commands, respectively executes
         the command.



2.3.3.3  L̲o̲a̲d̲i̲n̲g̲ ̲o̲f̲ ̲N̲e̲w̲ ̲V̲e̲r̲s̲i̲o̲n̲s̲ ̲o̲f̲ ̲S̲y̲s̲t̲e̲m̲ ̲a̲n̲d̲ ̲A̲p̲p̲l̲i̲c̲a̲t̲i̲o̲n̲ ̲F̲i̲r̲m̲w̲a̲r̲e̲

         Loading of newversions of application and system software
         is possible in all start-up cases, except WARM2 (after
         switchover).…86…1         …02…   …02…   …02…   …02…                   
                                
2.3.4    A̲c̲c̲u̲r̲a̲c̲y̲ ̲a̲n̲d̲ ̲V̲a̲l̲i̲d̲i̲t̲y̲



2.3.4.1  A̲c̲c̲u̲r̲a̲c̲y̲ ̲a̲n̲d̲ ̲I̲n̲p̲u̲t̲ ̲D̲a̲t̲a̲

         Commands and reports received by the SSC package are
         validated for the data range required for an internal
         processig of the input. E.g. type and function code
         are checked to be within certain ranges.

         For operator commands a syntax and semantic check is
         performed either in the VDU or in the SSC on all input
         data.

         A protocol is used between the WDP and a PU t ensure
         an error free transmission of data.



2.3.4.2  A̲c̲c̲u̲r̲a̲c̲y̲ ̲o̲f̲ ̲T̲r̲a̲n̲s̲m̲i̲t̲t̲e̲d̲ ̲D̲a̲t̲a̲

         Data to be transmitted to other packages must be checked
         by the receiver.