DataMuseum.dk

Presents historical artifacts from the history of:

CR80 Wang WCS documentation floppies

This is an automatic "excavation" of a thematic subset of
artifacts from Datamuseum.dk's BitArchive.

See our Wiki for more about CR80 Wang WCS documentation floppies

Excavated with: AutoArchaeologist - Free & Open Source Software.


top - download

⟦e03626f0f⟧ Wang Wps File

    Length: 5418 (0x152a)
    Types: Wang Wps File
    Notes: CPS REM.TER.,DES. NOTE.   
    Names: »0624A «

Derivation

└─⟦c36200119⟧ Bits:30006003 8" Wang WCS floppy, CR 0038A
    └─ ⟦this⟧ »0624A « 

WangText




…02…CPS/TCN/021

…02…DL/810210…02……02…#
CAMPS REMOTE TERMINALS, DESIGN NOTE
EQUIPMENT BREAKDOWN…02……02…CAMPS









                 T̲A̲B̲L̲E̲ ̲O̲F̲ ̲C̲O̲N̲T̲E̲N̲T̲S̲



   1  SCOPE ........................................ 
     3

   2  APPLICABLE DOCUMENTS/REFERENCES .............. 
     3

   3  GENERAL DESCRIPTION .......................... 
     3

   4  DETAILED DESCRIPTION ......................... 
     4
     4.1  TEMPEST-RACKS ............................ 
       4
     4.2  OPTO-CABLE DESIGN ........................ 
       4
     4.3  TERMINAL CONNECTIONS ..................... 
       5

   5  APPENDIX A ................................... 
     7



                         1̲ ̲ ̲S̲C̲O̲P̲E̲



         Based on references 2.1 and 2.2 a design of the expansion
         of the CAMPS with the remote terminals has been worked
         out. The equipment break down is presented in Appendix
         A, where it is compared to the equipment list of references
         2.1 and 2.2.



            2̲ ̲ ̲A̲P̲P̲L̲I̲C̲A̲B̲L̲E̲ ̲D̲O̲C̲U̲M̲E̲N̲T̲S̲/̲R̲E̲F̲E̲R̲E̲N̲C̲E̲S̲



2.1      SHAPE, Letter of Intent
         80-9008-3-INF/SHNMOC/80



2.2      CAMPS System Design Specification
         CPS/SDS/001



                  3̲ ̲ ̲G̲E̲N̲E̲R̲A̲L̲ ̲D̲E̲S̲C̲R̲I̲P̲T̲I̲O̲N̲



         The equipment matrix (Appendix A page 10) is based
         on:

         a)  Remote Terminal, Main Location equipment is placed
             in a separate TEMPEST-rack.

         b)  Items requested in reference 2.1 and not used in
             the sites are places as spares.





                 4̲ ̲ ̲D̲E̲T̲A̲I̲L̲E̲D̲ ̲D̲E̲S̲C̲R̲I̲P̲T̲I̲O̲N̲



4.1      T̲E̲M̲P̲E̲S̲T̲-̲R̲A̲C̲K̲S̲



4.1.1    The marked main site racks in Appendix A page 12 indicates
         that the design (reference 2.2) of the main site racks
         D, E, F leave place for inclusion of remote terminal,
         main location equipment.

         The installation of an extra TEMPEST-rack may thus
         not be required.



4.1.2    In the main sites n̲o̲t̲ marked in Appendix A page 12,
         additional TEMPEST-racks have to be added to the line
         termination racks D, E, F.



4.1.3    The site designs (from site surveys) should be checked
         carefully to assure that the required space for additional
         TEMPEST-racks can be provided.

         Special attention should be paid to PROTO and UK AIR.



4.2      T̲H̲E̲ ̲O̲P̲T̲O̲-̲C̲A̲B̲L̲E̲ ̲D̲E̲S̲I̲G̲N̲

         The opto-cable design for remote connections, Appendix
         A page 9, is the CR interpretation of reference 2.1.

         CR has not mentioned this concept in the proposals.

         Comments:



4.2.1    Cost for establishing a modem-link from main to remote
         sites:





4.2.1.1  O̲P̲T̲O̲-̲M̲o̲d̲e̲m̲ ̲L̲i̲n̲k̲ (max. 2400 Baud)

         -   two opto-modem assemblies are needed:

             2 x opto crate =         2 x  2.220 Dkr =   4.440 Dkr
             2 x opto power supply =  2 x 15.698 Dkr =  31.396 Dkr
             2 x opto mux/demux
                 transceiver          2 x 11.873 Dkr =  2̲3̲.̲7̲4̲6̲ ̲D̲k̲r̲

                                                        59.582 Dkr

         -   opto cable:

             connectors =             400 Dkr/pair
             cable (dual) =            55 Dkr/m



4.2.1.2  "̲E̲l̲e̲c̲t̲r̲i̲c̲a̲l̲"̲-̲M̲o̲d̲e̲m̲ ̲L̲i̲n̲k̲ ̲(max. 2400 Baud)

         -   two modem assemblies are needed:

             2 x modem =              2 x 17.834 Dkr =  35.668
                                                        Dkr
                                                        

             cable =                  ?



4.2.2    Identical design on all sites is recommended (Electrical
         modem).



4.3      T̲E̲R̲M̲I̲N̲A̲L̲ ̲C̲O̲N̲N̲E̲C̲T̲I̲O̲N̲S̲

         SHAPE has asked CR to evaluate the opto-versus the
         V24/V28-connection to terminals in the remote sites.

         The two design concepts are shown on page 8 and 9 in
         Appendix A.

         Comments:





4.3.1    V̲2̲4̲/̲V̲2̲8̲-̲L̲i̲n̲k̲s̲

         Cost of establishing the first V24/V28-link to one
         terminal, designed to meet the security requirements
         applicable for CAMPS main-contract:

             1 x LTUX crate =         1 x 14.227 Dkr =  14.227
                                                        Dkr
             1 x Power supply =       1 x 15.698 Dkr =  15.698
                                                        Dkr
             1 x Filter box =         1 x 13.500 Dkr =  13.500
                                                        Dkr
             2 x V24(L) adaptors =    2 x 11.000 Dkr =  22.000
                                                        Dkr
             1 x V24 cable =          ?
                                                         ̲ ̲ ̲
                                                        ̲ ̲ ̲ ̲
                                                        ̲ ̲ ̲

                                                        65.425
                                                        Dkr

         Cost of an additional channel (up to a total of 8)

             2 x V24(L) adaptors =    2 x 11.000 Dkr =  22.000
                                                        Dkr
             1 x V24 Cable =          ?



4.3.2    O̲p̲t̲o̲-̲L̲i̲n̲k̲s̲

         Cost of the first opto-link to a standard terminal
         (V24/V28 - I/F):

         1 x Opto crate         has been mounted
         1 x Opto power supply  on all remote sites  =     
                                                         0
         2 x Opto mux/demux
             transceivers =           2 x 11.873 Dkr =  23.746
                                                        Dkr

             cable = 400 Dkr/pair + 55 Dkr/m

         Cost of an additional opto-link (up to a total of 8)

         2 x opto mux/demux transceiver =               23.746
                                                        Dkr
             cable = 400 Dkr/pair + 55 Dkr/m














                      5̲ ̲ ̲A̲P̲P̲E̲N̲D̲I̲X̲ ̲A̲



                 REMOTE TERMINALS DESIGN

                   EQUIPMENT BREAKDOWN



5.1      N̲O̲T̲E̲S̲ ̲T̲O̲ ̲A̲P̲P̲E̲N̲D̲I̲X̲ ̲A̲

         p. 8 and 9:    The     marks the items which are n̲o̲t̲
                        supplied by CR.

         p. 10 and 12:  The Main site #'s are according to CR
                        H/W standard.

                        The equipment list #'s on top of the
                        matrix are referring to the unit #'s
                        p. 11.

                        The numbers in the matrix describe the
                        number of units needed in the CR design
                        for each site.

         p. 11          The Total Equipment List shows all the
                        units delivered by CR for the remote
                        terminals.

                        The difference-column shows the extra
                        units needed to perform the CR design.

                        The   1   unit- and total-prices are
                        the ones reference 2.1.

                        The   2   unit- and total-prices show
                        the cost of the CR design.