WangText

…00……00……00……00……00…G…02……00……00…G G…05…F…0b…F…0e…F…02…F…06…E…0a…E…0f…E…01……86…1                                             …02…           …02…   …02…        

2845A/ktd/ …02…CPS/TCM/005

…02…KJA/830912…02……02… 
CAMPS SITE LEVEL MAINTENANCE MANUAL
…02…Issue 1…02…CAMPS
 
 WATCHDOG TEST PROCEDURES STEP 3000-4000 (cont'd)

 STEP     PROCEDURE                    OBSERVATION/ACTION
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲





2845A/ktd/ …02…CPS/TCM/005

…02…KJA/830912…02……02… 
CAMPS SITE LEVEL MAINTENANCE MANUAL
…02…Issue 1…02…CAMPS
 



















4.3.3.3    W̲a̲t̲c̲h̲d̲o̲g̲ ̲T̲e̲s̲t̲ ̲P̲r̲o̲c̲e̲d̲u̲r̲e̲s̲


    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *

3000                      WD TEST   ENTRY

                          The WD monitors and controls
                          the CAMPS H/W.

                          If the WD fails, it is automatically
                          takenout of service and the objects
                          controlled by the WD will remain
                          unchanged. The system S/W will
                          direct the active PU error messages
                          to the supervisor report printer.

                          It is still possible to monitor
                          and reconfigure the CAMPS system
                          by LED indicatin and switchsettings
                          on the modules.

                          If the CAMPS system is reconfigured,
                          it is possible to communicate
                          with one of the PUs. The reconfiguration
                          procedure is described in step
                          3450. The boot and start commands
                          are not changed if the system
                          is reonfigured as described in
                          step 3450.

                          If the maintenance position VDU
                          fails, then the WD operation
                          not involving the VDU and the
                          printer continues.

                          If the maintenance position printer
                          fails, the system S/W directs
                          the active PU error messages
                          o the supervisor report printer.
                          The WD continues operations not
                          involving the VDU subsystem at
                          site level.

                          In case of an error in the WD,
                          the only remedy is to order a
                          new WD from the depot.

                          The test described in this section
                          of the WD is reuced to a functional
                          test in order to decide whether
                          the WD is working or not.

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *




3005  Analyze the error   o If the error report is as foloows:
                              
    situation                          
                            CCBXXX

                          then
                            GO TO step 3300

                          o If there is an error indication
                            in:

                            Mait. Pos. VDU - WD - PU

                          then

                            GO TO step 3400

                          o If there is an error indication
                            in:

                            Maint. Pos. MSP - WD - PU

                          then

                            GO TO step 3500

                          o If there is discovered an error
                            in one of the

                            CONTROL/ASSIGN commands

                            or

                          STATUS setup in FORMAT AREA

                          described in the 

                            Maintenance Position Operation

                            Manual Doc. No. CPS/OPM/005

                          then

                            GO TO step 3600

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *…86…1    …02…                     …02… …02…    …02…  …02…      
                           
    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *

3300  Error detected BY WD  ENTRY

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *



3305  Analyz the error    o If one of the following power
                            level error reports appears

                            CCB001
                            CCB005
                            CCB007
                            CCB013
                            CCB014
                            CCB016
                            CCB022
                            CCB024

                          then GO TO step 3310

      o                   If one of the following switch
                          setting reports appears

                          CCB006
                            CCB008
                            CCB011 - CCB012
                            CCB026

                          then GO TO step 3315

      o                   If one of the following digital
                          error reports appears:

                            CCB018
                            CCB023
                            CCB025

                          then GO TO step 3320

      o                   If one of the following temperature
                          error reportsappears:

                            CCB003
                            CCB009
                            CCB020

                          then GO TO step 3330
    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *…86…1    …02…         …02…           …02… …02…    …02…  …02…       
                          
3310  Check the power     o If the power level is not correct
    level in the actual     neither on the motherboard
                            nor on the
    crate. The actual       CCA (if any) then isolate the
                            error
    stes describing         as described in crate check
                            procedcure.
    the power level
    test procedure
    are listed below.

    C̲r̲a̲t̲e̲ ̲ ̲ ̲ ̲S̲t̲e̲p̲

    PU                    1805
    CU                    2805
    TDX                   4805
     ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲

                          o If the power level is correct
                            on the motherbord then it indicates
                            an error n the WD Subsystem.

                                 Check the cables connected
                                 to the CCBA and the CCA/BSM-X.
                                 Replace the CCA/BSM-X
                                 (if necessary)

                            If the error still appears
                            then it indicates an error
                            in the WD.

                                 Check the WD Crate (refer
                                 to step 3800)
                            Verify the WD Subsystem
                                 GO TO step 3900.

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *…86…1    …02…         …02…           …02… …02…    …02…  …02…       
                          
    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *
3315  Check the switchs-  o If the switchsettings are as
                            described
    settings in the         in the error report then no
                            eror is
    actual crate modules.   present.
    The switchsset-
    tings are des-
    cribed in section
    4.5.

                          o If the switchssettings are
                            not as described in the error
                            report then it indicates an
                            error in the WD Subsystem.

                                 Check the cable connectors
                                 o the CCBA and the
                                 CCA/BSMs.

                            If the error is still present
                            then the replacement of the
                            following modules are necessary
                            in order to isolate the error.

                            In the PU crate:

                                 CCA/MAP/MIA

                            In the CU crate:

                                 CCA/CUCP

                            In theTDX crate:

                                 BSM-X

                            If the error is still present
                            then it indicates an error
                            in the WD.

                                 Check the WD (refer to
                                 step 3800)
                                 Verify the WD Subsystem
 
                                 GO TO step 3900…86…1    …02… 
                                        …02…           …02… …02…  
                                  …02…  …02…                  
                                            
    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *
3320  Check the LEDs      o If there is no LED error indication
                            
    in the TDX crate        in the TDX crate 
    (ref. to sec.4.5        then 
                                 
                                 GO TO step 3325

                          o If there is error indication
                            then correct it or replace
                            the failing item (refer to
                            step 4300).
                                 Verify the WD Subsystem
                                 GO TO step 3900.

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * ** *

3325  It is necessary to  o If it is possible to execute
                            the tests
    test the actual         using the WD commands then
                            the error
    TDX crate using         has disappeared.
    S/W commands and
    not the switches             Verify the WD Subsystem
    on the front of
    the BSM-.                    GO TO step 3900.

    The tests consist of:

    TDX-BUS and
    LTUX-STATUS

    (These tests are
    described in
    step 4300-4400)

                          o If it is not possible to run
                            the tests then isolate the
                            error as described in the offline
                            troubleshooting tree.

                                 (rfer to step 4300)…86…1 
                                   …02…         …02…          
                                 …02… …02…    …02…  …02…              
                                                
                          o If it is necessary to use the
                            switches then it indicates
                            an error in the WD subsystem.

                                 Check the cables connected
                                 to the CCBA and the BSM-X.
                                 Replace the BSM-X
                            (if necessary)

                            If the error indication has
                            not disappeared then

                                 Check the WD
                                 (Refer to step 3800) and
                                 
                                 Verify the WD Subsystem
                                 GO TO step 3900

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *…86…1    …02…         …02…           …02… …02…    …02…  …02…       
                          
3330  Check the tempera-  o If correct then it indicates
                            an error
    ture level in the       in the termostat or in the
                            WD 
    actual crate.           Subsystem.
    The level should             
    be within the           Check that the thermostat is
                               
    range                           connected and adjusted
                                    properly.
    05…0e…0…0f… - 40…0e…0…0f…                    Replace the thermostat
                                 (if necessary)

                            If the error has not disappeared
                            then

                                 Replace the BSM-X/CCA

                          o If the temperature is out of
                            rangethen

                                 Check (and replace) the
                                 FAN and

                                 then

                                 Verify the WD Subsystem

                                 GO TO step 3900.

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *…86…1    …02…         …02…           …02… …02…    …02…  …02…       
                          
    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *

3400  Test of the Maint.  ENTRY
    Pos. VDU-PU 
    Communication

    * * * * * * * * * * * * * * * * * * * * * * * * * **
    * * * * *




3405  Analyze the situ-   o If one of the PUs is online
                            then the   
    ation:                       system is still operating.

                                 GO TO step 3410

                          o If none of the PUs is online
                            then

                                 GO TO step 3450

    * * * * * * * * * * * * * * * * * * * * *  * * * *
    * * * * * *

3410  Check that it is    o If correct then
    possible to com-             GO TO step 3415
    municate with 
    the online PU.
    The command is:

    PUNno (ENTER)

    "no" is the number
    of the online PU
    (refer to
    Doc.No.CPS/OPM/005)

                          o If it isnot possible then

                                 GO TO step 3425

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *