⟦e273383d9⟧ Wang Wps File

    Length: 5069 (0x13cd)
    Types: Wang Wps File
    Notes: PC/TRP/0003 (is. 1.)      
    Names: »4448A «

Derivation

└─⟦3928290b5⟧ Bits:30006240 8" Wang WCS floppy, CR 0407A
    └─ ⟦this⟧ »4448A « 

WangText




…02…PC/TRP/0003

…02…BHE/831229…02……02…#
PROTOCOL CONVERTER
FACTORY ACCEPTANCE TEST REPORT, SITE 3…02……02…   PC












                 PROTOCOL CONVERTER
                 FACTORY ACCEPTANCE TEST
                 REPORT, SITE 3


                 PC/TRP/0003

                 Line Item No. 1.14











                 B]rge Hermansen





                 B[RGE HERMANSEN







                 SHAPE (2), DL.                   
                                                      














                         …0f…                          


         1



         831229                               



                                               PC/TRP/0003

…02…BHE/831229…02…   ii
PROTOCOL CONVERTER
FACTORY ACCEPTANCE TEST REPORT, SITE 3…02…      …02…   PC 
…0f…












       831229                   All        Initial issue of
                     Document



            …02…PC/TRP/0003

…02…BHE/831229…02…                                   iii
PROTOCOL CONVERTER
FACTORY ACCEPTANCE TEST REPORT, SITE 3…02…        …02…    PC 










                                      TABLE OF CONTENTS


 1 GENERAL ..........................................
   1 

   1.1 PURPOSE ......................................
         1 
   1.2 APPLICABLE DOCUMENTS .........................
         1 

 2 TEST OVERVIEW ....................................
   1 

   2.1 CONTRACTUAL REFERENCES .......................
         1 
   2.2 TEST BASELINE ................................
         2 

 3 TEST GROUND RULES ................................
   2 

 4 TEST CONDUCTORS ..................................
   3 


 A̲P̲P̲E̲N̲D̲I̲C̲E̲S̲


 APP. A:     PROTOCOL CONVERTER ACCEPTANCE TEST
             PROCEDURES, SITE 2, (PC/TPR/0001(2.2))
               SEC. 2

 APP. B:     TEST LOG, PC SITE 3                   
               SEC. 3

 APP. C:     CONFIGURATION LIST 831224             
               SEC. 4

 APP. D:     FAT-APPLIED MESSAGES                  
               SEC. 5

 APP. E:     RELATED COMPUTER PRINTOUTS G.F.C. 4.5.3
              SEC. 6

 APP. F:     RELATED COMPUTER PRINTOUTS G.F.C. 4.5.4
              SEC. 7


                        1 G̲E̲N̲E̲R̲A̲L̲



1.1      P̲U̲R̲P̲O̲S̲E̲

         The purpose of this document is to describe the result
         of the SITE 3 Factory Acceptance Test, which took place
         at the Christian Rovsing A/S facilities on 831215 and
         831228.



1.2      A̲P̲P̲L̲I̲C̲A̲B̲L̲E̲ ̲D̲O̲C̲U̲M̲E̲N̲T̲S̲

         a)  Protocol Converter Test Plan
             Contract SHNMO-82-9205-INF.
             PC/TPL/001, issue 3.

         b)  Protocol Converter Acceptance Test Procedures
             Contract SHNMO-82-9205-INF.
             PC/TPR/001, issue 2.2.



                     2 T̲E̲S̲T̲ ̲O̲V̲E̲R̲V̲I̲E̲W̲



2.1      C̲O̲N̲T̲R̲A̲C̲T̲U̲A̲L̲ ̲R̲E̲F̲E̲R̲E̲N̲C̲E̲S̲

         On the dates of 15 and 28 of November, 1983, the 
         Site 3 Factory Acceptance Test was completed successfully.

         The test is specified in the Protocol Converter Test
         Plan para's 3.3.2 to 3.3.2.6 and the Protocol Converter
         Contract Clause 14.3.





2.2      T̲E̲S̲T̲ ̲B̲A̲S̲E̲L̲I̲N̲E̲

         The Factory Acceptance Test Report (this document)
         is divided into 7 sections:

         1.  Protocol Converter Factory Acceptance Test Report,
             Site 3, 
             PC/TRP/0002(1).

         2.  Protocol Converter Acceptance Test Procedures,
             
             Site 3,
             PC/TPR/0001 (2.2)                        App. A.

         3.  Test Log, PC Site 3.                     App. B.

         4.  Configuration List 831215                App. C.

         5.  FAT-APPLIED MESSAGES                     App. D.

         6.  RELATED COMPUTER PRINTOUTS G.F.C. 4.5.3  App. E.

         7.  RELATED COMPUTER PRINTOUTS G.F.C. 4.5.4  App. F.


                   3 T̲E̲S̲T̲ ̲G̲R̲O̲U̲N̲D̲ ̲R̲U̲L̲E̲S̲




         The Site 3 FAT was based on the sequences of tests
         described in the test procedures in the document "Protocol
         Converter Acceptance Test Procedures, Site 3, PC/TPR/0001(2.2).

         During the tests, the results was noted in the test
         procedure and the test log. If any comments were necessary,
         these were noted in the test procedure and test log
         as well.
         If a problem was encountered during the test, the problem
         was either catagorised as a descrepancy or a defect.
         By a descrepancy is meant a mutually agreed issue showing
         an agreed date for clearance of the issue. By a defect
         is meant a problem which prevented the acceptance of
         the test.



         Also problems encountered during the test were divided
         into two further categories:

         o   Board Failures

         o   System Level Failures.

         Board failures were corrected immediately by replacement
         of the board. System level failures were corrected
         after the first test was completed and a retest was
         performed.



                    4 T̲E̲S̲T̲ ̲C̲O̲N̲D̲U̲C̲T̲O̲R̲S̲



         The following test team conducted the test:

         [strup, Thorvald            SHAPE Representative (GQAR)
         Hermansen, Boerge           PC Program Manager
         Holgersen, Erik             PC S/W Engineer
         Plesner, Kenneth            PC S/W Engineer
         Larsen, Djon                PC H/W Engineer
         Strandtoft, Benny           CR QA S/W
         Villadsen, Erik             CR QA H/W

         CR QA maintained the official copy of the test results.