⟦e547229a5⟧ Wang Wps File

    Length: 8553 (0x2169)
    Types: Wang Wps File
    Notes: CPS/TMA/???     (Week 12) 
    Names: »4312A «

Derivation

└─⟦9753ba4d5⟧ Bits:30006173 8" Wang WCS floppy, CR 0253A
    └─ ⟦this⟧ »4312A « 

WangText

…00……00……00……00……00…4…0a……86…1                                             …02…           …02…   …02…        

…02…4312A/ktd  

…02…BJR/831117…02……02…#
STUDENT LABORATORY GUIDE
…02……02…CAMPS








         WARNINGS:



         1   If you are not in the User Menu, do not press ATTN.



         2   Do not use SUSPEND. Use DEFER instead.



         3   Do not insert (F2) lines in messages and do not
             insert more than 10 lines in COMMENT. Do not use
             F2 and F4 in T-TO-T COMMENT and VDU Display.



         4   Do not press MASTER RESET or RESET.



         5   Do not use PRINT (F3) in T-TO-T COMMENT and VDU
             Display.





1        Sign On.





2        Prepare three comments, all of them for local distribution
         to:

         DSA AEC NUC DSB CRA NBC

         Use the following classifications and precedences:

         1   RESTRICTED     IMMEDIATE
         2   CONFIDENTIAL   PRIORITY
         3   SECRET         ROUTINE

         Send the two first comments and defer the third one.





3        Continue preparation of the third comment. Do you remember
         the ITEM REF ID?

         Use "OUTGOING MESSAGE/COMMENT STATUS" to find the number.

         Print out the status report on the associated printer.

         Send the comment.





4        Prepare a message with the following data:

         CLASSIFICAION:         SECRET
         COORDINATION:          One of the SCD's belonging to
                                your terminal.
         LOCAL DISTRIBUTION:    The same as for coordination.
         FROM:                  NMR SHAPE CA
         TO:                    ZEN/AB EINDHOVEN
         INFO:                  ZEN/0153
                                ZEN/AIR TOUL
         SIC:                   BSJ
         EXER/OPER:             OPER/RST-COURSE

         Send the message for coordination.







5        Check outgoing status. Is it correct?





6        Do you have a message for coordination? If no, go to
         step 4.

         Receive the message and print it out.

         Do you still have the same "INFO" line? Is the "INFO"
         line still correct?





7        Change the "TO" line of the message you prepared to:
         ZEN/COMMCEN COPENHAGEN.

         Send the message for release.





8        Go to your release position and release your message.





9        Go back to your own position and read the release notification.





10       Check outgoing status. Is it correct?





11       Check delivery status. Do you have your own message
         after local distribution?

         If yes, receive it.







12       Retrieve the second comment.





13       Retrieve the message you have sent.





14       Delete the first comment.





15       Prepare a T-to-T comment. Send it to CCIS.





16       Prepare a VDU display. Use the name: BEER.

         Do not send the VDU display, update the data base instead.





17       It is the last step, check outgoing and delivery status
         and print them out on the printer.





                          E N D



1        Block the terminal with the TD:OPD by misspelling the
         password three times. Open the terminal again from
         the Supervisor position.

         Did you get an error report on the Supervisor report
         printer?





2        Make yourself a user profile with your own ID and password.
         Set capabilities for preparation, reception, and release
         to yes. Set exercise messages only to no. Set associated
         release terminal to OPB.





3        Put yourself into the terminal profile for TD:OPC.





4        Try to sign-on with your ID at TD:OPC. If it is not
         possible, check your user profile and the terminal
         profile for TD:OPC.





5        Send two comments from another terminal to one of the
         SCD's which are belonging to TD:OPC.







6        Block the queue for TD:OPC.





7        Send a comment from another terminal to one of the
         SCD's which are belonging to TD:OPC.
         Check the queue for TD:OPC, what happened?





8        Prepare a comment at TD:OPC. Instead of sending it,
         defer it.





9        Delete a̲l̲l̲ the queues for TD:OPC. Check the queue status
         for TD:OPC, what happened:





10       Try to receive comments at TD:OPC. What happened?





11       Try to continue preparation of the comment you deferred.
         What happened?





12       Find out to which LTUX Line No. the report printer
         for the Supervisor is connected, w̲i̲t̲h̲o̲u̲t̲ looking on
         the cables.





1        Make a new text for MHI:ZZP. Go to TD:OPC and prepare
         a message.
         Check the MHI.





2        Protect the Security Control Command "SECC" by a Command
         Code and a warning text.
         Check it.





3        Print out all the AIGs.





4        Make a new security warning text. Set security interrogation
         to RR. Set security warning to UU.
         Check it.





5        Set quiet-hour terminal to TD:OPC. Send a comment from
         TD:OPD with precedence: ZZ to a closed terminal. 
         What happened?





6        Make a new user profile.





7        Print out the password list.



8        Print out the system parameters.





9        Set statistic print to: OFF.





10       Suspend the retrieve function.





11       Set quiet-hour to: OFF.





12       Print out a terminal profile.





13       Print out a user profile.…86…1         …02…   …02…   …02…   …02…      
                                             
…0c…skrives ud uden hoved…0c…






         U̲N̲S̲O̲L̲I̲C̲I̲T̲E̲D̲ ̲D̲I̲R̲E̲C̲T̲I̲V̲E̲S̲



         -   ILLEGAL ̲FUNCTION ̲KEY ENTRY

         -   CURSOR ̲NOT ̲POSITIONED ̲IN ̲FORMATTED ̲LINE

         -   TOP ̲LEVEL ̲MENU ̲ALREADY ̲DISPLAYED

         -   PARAMETER ̲1 ̲SYNTAX ̲ERROR

         -   PARAMETER ̲2 ̲SYNTAX ̲ERROR

         -   PARAMETER ̲3 ̲SYNTAX ̲ERROR

         -   PARAMETER ̲4 ̲SYNTAX ̲ERROR

         -   PARAMETER ̲1 ̲RANGE ̲ERROR

         -   PARAMETER ̲2 ̲RANGE ̲ERROR

         -   PARAMETER ̲3 ̲RANGE ERROR

         -   PARAMETER ̲4 ̲RANGE ̲ERROR

         -   CONFIRMATION ̲CODE ̲NOT ̲ENTERED

         -   CONFIRMATION ̲CODE ̲SYNTAX ̲ERROR

         -   ILLEGAL ̲CONFIRMATION ̲CODE

         -   CURSOR ̲NOT ̲POSITIONED ̲CORRECT ̲IN ̲DATA ̲ENTRY ̲FIELD

         -   COMMAND ̲CODE ̲SYNTAX ̲ERROR

         -   UNKNOWN ̲COMMAND

         -   MISSING ̲PARAMETER ̲OR ̲PEC

         -   TOO ̲MANY ̲PARAMETERS

         -   MISSING PARAMETERS

         -   PEC ̲SYNTAX ̲ERROR

         -   ILLEGAL ̲PEC

         -   TABLE ̲FULL










         U̲N̲S̲O̲L̲I̲C̲I̲T̲E̲D̲ ̲D̲I̲R̲E̲C̲T̲I̲V̲E̲S̲ (cont'd)



         -   UNDEFINED ̲VDU

         -   UNDEFINED ̲DEVICE

         -   ATOMAL ̲PRINT ̲DEVICE

         -   DEDICATED ̲PUNCH ̲DEVICE

         -   DEDICATED ̲READER ̲DEVICE

         -   UNDEFINED ̲VDU ̲OR ̲DEVICE

         -   UNKNOWN ̲INCOMING ̲CHANNEL ̲DESIGNATOR

         -   UNKNOWN ̲OUTGOIND ̲CHANNEL ̲DESIGNATOR

         -   UNKNOWN ̲USER

         -   USER ̲SIGNED ̲ON

         -   TABLE ̲AND ̲OVERLOAD ̲AREA ̲FULL

         -   OVERLOAD ̲AREA ̲FULL

         -   PLA ̲REFERENCE ̲NO ̲IDENTIFIES ̲A ̲LOCAL ̲PLA

         -   PLA ̲REFERENCE ̲NO ̲IDENTIFIES ̲A ̲GLOBAL ̲PLA

         -   COMMAND ̲NOT ̲DEFINED ̲FOR ̲CURRENT ̲MODE

         -   NUMBER ̲OF ̲LINES ̲TOO ̲LARGE ̲OR ̲INSERTION ̲NOT ̲ALLOWED

         -   NUMBER ̲OF ̲LINES ̲TOO ̲LARGE ̲OR ̲DELETION ̲NOT ̲ALLOWED

         -   CAMPS ̲BUSY

         -   TABLE ̲ENTRY ̲EXISTS ̲BUT ̲ILLEGAL ̲TYPE

         -   TABLE ̲LOCKED









        E̲R̲R̲O̲R̲ ̲C̲O̲D̲E̲S̲



        E̲R̲R̲O̲R̲ ̲C̲O̲D̲E̲   E̲X̲P̲L̲A̲N̲A̲T̲I̲O̲N̲

           100       RI ̲NOT ̲IN ̲EXTERNAL ̲RI ̲TABLE

           101       EXTERNAL ̲RI ̲CIRCUIT ̲WAS ̲NOT ̲FOURN

           102       SYSTEM ̲CODE ̲IN ̲CONFLICT ̲WITH ̲GLOBAL

           103       DD ̲ALREADY ̲EXISTS ̲IN ̲TT

           104       DD ̲ALREADY ̲EXISTS ̲IN ̲DT

           105       UNKNOWN ̲TERMINAL ̲DESIGNATOR

           106       UNKNOWN ̲DEVICE ̲DESIGNATOR

           107       TYPE ̲IS ̲NOT ̲AS ̲SPECIFIED ̲IN ̲TERM ̲DEV ̲PROFILE

           108       SCD ̲NOT ̲IN ̲TERMINAL ̲PROFILE

           109       CD ̲ALREADY ̲EXISTS

           110       DEVICEQ ̲NOT ̲BLKED ̲OR ̲EMPTY

           111       NEW ̲DEV ̲PORT ̲ALREADY ̲EXISTS

           112       DEVICE ̲TYPE ̲INCOMPATIBLE

           113       CHANNEL ̲MUST ̲BE ̲DISCONNECTED ̲BEFORE ̲PROFILE
                     ̲DELETION

           114       UPDATE ̲NOT ̲ALLOWED ̲UNLESS ̲DISCONNECTED

           115       CHANNEL ̲PORT ̲NOT ̲ENTERED

           116       PORT ̲ID ̲DOES ̲NOT ̲EXIST

           117       UNKNOWN ̲CIRCUIT

           118       CIRC ̲NO ̲CANNOT ̲BE ̲CHANGED

           119       TYPE ̲MISMATCH







        E̲R̲R̲O̲R̲ ̲C̲O̲D̲E̲S̲ (cont'd)



        E̲R̲R̲O̲R̲ ̲C̲O̲D̲E̲   E̲X̲P̲L̲A̲N̲A̲T̲I̲O̲N̲

           120       CHANNEL ̲NOT ̲CONNECTED ̲YET

           121       UNKNOWN ̲SDL

           122       SDL ̲LIST ̲IS ̲EMPTY

           123       AT ̲LEAST ̲ONE ̲SDL ̲MUST ̲BE ̲SPECIFIED

           124       PLA ̲IS ̲ASSOCIATED ̲WITH ̲ANOTHER ̲PLA ̲REF

           125       PLA ̲CANNOT BE CHANGED

           126       SCD ̲NOT ̲FOUND ̲IN ̲SCD ̲TABLE

           127       NUMBER ̲OF ̲CONNECTED ̲CHANNELS ̲IS ̲NOT ̲0

           128       NETWORK ̲DOES ̲NOT ̲CORRESPOND ̲TO ̲CIRCUIT ̲TYPE

           129       NO ̲CAPABILITY ̲SPECIFIED

           130       TERMINAL ̲DOES ̲NOT ̲HAVE ̲RELEASE ̲CAPABILITY

           131       EXPIRES ̲MUST ̲BE ̲0 ̲WHEN SUPERVISOR

           132       PLA ̲ASSOCIATED ̲ANOTHER ̲GLOBAL ̲PLA ̲REF

           133       PLA ̲ASSOCIATED ̲A ̲LOCAL ̲PLA ̲REF

           134       UNKNOWN ̲RI

           135       FIRST ̲RI ̲MUST ̲BE ̲EITHER ̲NICS ̲TARE ̲SCARS ̲OR
                     ̲CCIS

           136       IF ̲RI ̲IS ̲SCARS ̲OR ̲CCIS ̲ONLY ̲ONE ̲RI ̲IS ̲ALLOWED

           137       RI ̲CIRCUIT ̲TYPE ̲MUST ̲BE ̲TRC ̲PTOP

           138       GLOBAL ̲PLA ̲TABLE ̲CONFLICT