⟦e9aa1a573⟧ Wang Wps File

    Length: 1062 (0x426)
    Types: Wang Wps File
    Notes: Spelunked
    Names: »~ORPHAN03.11«

Derivation

└─⟦62d458081⟧ Bits:30006246 8" Wang WCS floppy, CR 0154A
    └─ ⟦this⟧ »~ORPHAN03.11« 

WangText

e̲m̲p̲e̲r̲a̲t̲u̲r̲e̲.  -  Para. 4.7.1.2.2 High temperature, non-operating.

3.1.2.1.2   L̲o̲w̲ ̲t̲e̲m̲p̲e̲r̲a̲t̲u̲r̲e̲.  -  Para. 4.7.1.3.1 Low temperature, non-operating.

3.1.2.2  S̲h̲o̲c̲k̲.
    Procedure 503-I, in NGTS-40. Temperature shock (non-operating) with the followin
    modifications:

    2 test sequences: high-low-high temperature
    and low-high-low temperature
    Dwell time at each temperature: 2 hours
    Transfer time:  15 minutes
    High temperature 71…0e…o…0f…C, low temperature -54…0e…o…0f…C.

3.2 ALTITUDE
  Proceure 500-I, in NGTS 40. Altitude, with the following levels:
  Operating 2000 m, Non-operating 50000 feet.

3.3 HUMIDITY
  Para. 3.3.3 and 4.7.4, in MPD 7005 C. Humidity, non-operating, where MIL-E-5272
  is replaced with MIL-STD-810C procedure 507-I.
3.4 SALT FOG
  Procedure 509-I, in NGTS 40. Salt Fog (non-operating)



NHMIS-173



3.5      VIBRATION

3.5.1    L̲o̲w̲ ̲f̲r̲e̲q̲u̲e̲n̲c̲y̲.  -  Para. 4.7.5.2.11, in MPD 7005
         C. Vibration, low frequency, nonoperating, with
         the following modifications:
             5Hz at 1.3 g for