6.2.1 I̲n̲s̲p̲e̲c̲t̲i̲o̲n̲

 The unit is inspected for loose or missing screws, knobs etc. and that there is no
 damage to the finishing.

 The list of all accessories is checked and collated. The unit is connected to the
 mains, and if it is not workableas a stand-alone equipment it is connected to test
 equipment or connected as part of a system. The unit is switched "on", and it is
 observed that it presumable is functioning, and after approximately 15 minutes that
 no smoke, excessive heat or smel is generated.



6.2.2 T̲e̲s̲t̲

 The basis for the test is the functional test described in para 3.4.

 Additional to this test a verification of the claimed MTBF is performed on a sample
 basis. 

 (For V.D.U.'s 10 samples out of 400 units will be usd). This verification is performed
 by running each sample for a duration of the claimed MTBF.…86…1         …02…        …02…    
    …02…              …02…         …02…            
                               7̲ ̲ ̲W̲O̲R̲K̲-̲L̲O̲A̲D̲ ̲P̲L̲A̲N̲

 The estimated work-load for the inspection and test including packing and handling
 is shown on Fig. 7-1.