   A P P E N D I X    B…01…**********************



    TECHNICAL REQUIREMENTS AND SPECIFICATIONS



The equipment to be supplied under this contract shall meet
 the following specifications and requirements listed below:





                 1̲ ̲ ̲T̲E̲M̲P̲E̲S̲T̲ ̲R̲E̲Q̲U̲I̲R̲E̲M̲E̲N̲T̲S̲



         The equipment shall have obtained a certificate of
         compliance with NATO Comsec tempest requirements from
         national authorities.

         If, however, modifications to a certified standard
         version of a piece of equipment, is required in order
         to comply with the requirements of this contract, it
         is acceptable that tempest certification will aplly
         to the standard version, and only supplementary test
         data confirming that the tempest integrity has been
         maintained will be required for the modified version.





                      2̲ ̲ ̲P̲O̲W̲E̲R̲ ̲I̲N̲P̲U̲T̲



         The equipment shall be capable of satisfying the specified
         performance requirements when operating with the following
         power input.



2.1      V̲O̲L̲T̲A̲G̲E̲

         The equipment shall be capable of operating with a
         220V AC Single phase as well as a 240V AC Single phase
         power supply, both with a tolerance of +10%/-15%.



2.2      F̲R̲E̲Q̲U̲E̲N̲C̲Y̲

         Nominal value: 50 Hz
         Tolerances:    +5/-5 Hz





2.3      H̲A̲R̲M̲O̲N̲I̲C̲ ̲D̲I̲S̲T̲O̲R̲T̲I̲O̲N̲

         Max. 5%.



2.4      T̲R̲A̲N̲S̲I̲E̲N̲T̲S̲

         Non-repetitive impulsive inteference with a magnitude
         not to exceed 500 volts, pulse rise and fall times
         not faster than 10 microseconds and a total duration
         of maximum 1 millisecond. The available impulse energy
         at the equipment power inlet shall not exceed 5 J.



2.5      S̲A̲F̲E̲T̲Y̲

         Where a voltage of more than 50 Volts is exposed during
         the maintenance activities, a suitable warning sign
         shall be provided on the equipment.



2.6      G̲R̲O̲U̲N̲D̲I̲N̲G̲

         The AC power neutral shall provide a return for the
         primary current, so that the equipment frame ground
         is used only to establish a safety ground.





               3̲ ̲ ̲E̲N̲V̲I̲R̲O̲N̲M̲E̲N̲T̲A̲L̲ ̲C̲O̲N̲D̲I̲T̲I̲O̲N̲S̲



         After initial adjustments have been made, the equipment
         shall maintain normal operation under worst-case of
         the specified environmental listed below:



3.1      A̲M̲B̲I̲E̲N̲T̲ ̲T̲E̲M̲P̲E̲R̲A̲T̲U̲R̲E̲

         0 to 50 deg. Celcius.

         Rate of change:  Max. 10 deg. Celcius per hour.





3.2      R̲E̲L̲A̲T̲I̲V̲E̲ ̲H̲U̲N̲I̲D̲I̲T̲Y̲ ̲(̲R̲H̲)̲

         40 to 90%, non-condensing.

         Rate of change:  Max. 6% RH per hour.



3.3      A̲L̲T̲I̲T̲U̲D̲E̲

         Sea level to 2000 meter.



3.4      D̲U̲S̲T̲ ̲A̲N̲D̲ ̲F̲U̲M̲E̲S̲

         The equipment shall continue to operate continuously
         in the following air environment.

         a)  A̲i̲r̲ ̲c̲l̲e̲a̲n̲n̲e̲s̲s̲

             Particle size (microns)   Max. allowable no. (part/m)

             greater than 5            4 x 10 E 5
             greater than 1,5          4 x 10 E 6
             greater than 1            4 x 10 E 7

         b)  F̲u̲m̲e̲s̲

             Sulphur dioxide max. 19 ppm.





               4̲ ̲ ̲T̲E̲C̲H̲N̲I̲C̲A̲L̲ ̲S̲P̲E̲C̲I̲F̲I̲C̲A̲T̲I̲O̲N̲S̲



4.1      D̲A̲T̲A̲ ̲L̲I̲N̲K̲ ̲S̲P̲E̲C̲I̲F̲I̲C̲A̲T̲I̲O̲N̲S̲

         The electrical interface specification shall comply
         with the CCITT V28 recommendation concerning the data-
         and control signal voltage polarities. All other characteristics
         are constrained by the MIL-STD-188C standard (low level)
         digital interface specification. (6-0-6V, 1mA and Waveshaping)
         Refer section 8 below. The interface signals must be
         free of HF-components.

         The functional interface specification shall comply
         with the CCITT V24 recommendation.



         The available interchange circuits shall be at least:

         101     Protective Ground
         102     Signal Ground
         103     Transmitted Data
         104     Received Data
         107     Data Set Ready
         108.2   Data Terminal Ready

         The equipment shall perform as a DTE or DCE device.

         The communication is asynchronous. 

         The interface can receive/transmit 5 - 8 bit code in
         transparency.

         The interface connector shall be a CANNON DB-25 or
         equivalent.



4.2      P̲U̲N̲C̲H̲ ̲F̲E̲A̲T̲U̲R̲E̲S̲

         a)  Punching speed: up to 60 char./sec.

         b)  Paper tape: Capable of punching both 11/16 inch.
             tape and 1 inch. tape without mechanical change.

         c)  Control: Equipped with buttons on fron for power
             on/off and punch start/stop. Automaitc motor stop
             on time and after last character received on interface.



4.3      R̲E̲A̲D̲ ̲F̲E̲A̲T̲U̲R̲E̲S̲

         a)  Reading Speed: Up to 150 char./sec.

         b)  Paper Tape: Capable of reading 11/16 inch paper
             tape with 5 bit code (IA No. 2) or 1 inch paper
             tape with 8 bit code (7 data + 1 parity).

         c)  Tape Loading: The reader should be suited for both
             reeled and non-reeled tape. No mechanical operation
             should be needed for changing between the two modes.

         d)  Control: Equipped with buttons on front for power
             on/off, and start/stop of reader. Reader can be
             stopped during transmission without loss of characters.





4.4      G̲E̲N̲E̲R̲A̲L̲ ̲F̲E̲A̲T̲U̲R̲E̲S̲

         K̲e̲y̲-̲l̲o̲c̲k̲

         A key-lock shall be incorporated in the equipment.
         All locks shall be individual and the key removable.

         When the terminal is locked no reading/punching must
         take place.

         A unique status signal shall be generated by the terminal
         when the terminal is locked or unlocked.

         The status signal must be provided as a data string
         (2 bytes long).

         The just defined status shall also be available upon
         request from the host by means of a command.

         Additionally, if the host attempts to punch when the
         terminal is locked an error code shall be sent to the
         host.





                      5̲ ̲ ̲M̲E̲C̲H̲A̲N̲I̲C̲A̲L̲



         The paper-tape puncher/reader shall be a free standing
         unit.





                         6̲ ̲ ̲M̲T̲B̲F̲



         The MTBF shall be more than 3000 hours, downtime not
         to exceed 30 mins. per month exclusive preventive maintenance.





                  7̲ ̲ ̲O̲T̲H̲E̲R̲ ̲R̲E̲Q̲U̲I̲R̲E̲M̲E̲N̲T̲S̲



         All other specifications will be in accordance with
         the applicable manual listed in Special Provisions
         paragraph 2 to this contract.


                     8̲ ̲ ̲M̲I̲L̲-̲S̲T̲D̲-̲1̲8̲8̲C̲



         The following part of MIL-STD-188C is applicable to
         this specification (Section number refers to the standard).