DataMuseum.dk

Presents historical artifacts from the history of:

CR80 Wang WCS documentation floppies

This is an automatic "excavation" of a thematic subset of
artifacts from Datamuseum.dk's BitArchive.

See our Wiki for more about CR80 Wang WCS documentation floppies

Excavated with: AutoArchaeologist - Free & Open Source Software.


top - download

⟦fce1a3624⟧ Wang Wps File

    Length: 4789 (0x12b5)
    Types: Wang Wps File
    Notes: Spelunked
    Names: »~ORPHAN43.00«

Derivation

└─⟦c15cad553⟧ Bits:30006230 8" Wang WCS floppy, CR 0124A
    └─ ⟦this⟧ »~ORPHAN43.00« 

WangText



                                                               T̲A̲B̲L̲E̲ ̲O̲F̲ ̲C̲O̲N̲T̲E̲N̲T̲S̲


   5.  LINE CIRCUIT STANDARDS ND INTERFACES  ....... 
          
     5.1 NICS TARE  .................................
             
     5.3 BROADCAST CIRCUIT  .........................
             
     5.4 SHIP-TO-SHORE Circuits  ....................
             
     5.5 MARITIME REAR LINK (MRL)  ..................
            
     5.6 CIRCUIT TO STANDBY MC  .....................
             
     5.7 TERMINAL CIRCUIT  ..........................
             …86…1         …02…   …02…   …02…   …02…                     
                              
5. L̲I̲N̲E̲ ̲C̲I̲R̲C̲U̲I̲T̲ ̲S̲T̲A̲N̲D̲A̲R̲D̲S̲ ̲A̲N̲D̲ ̲I̲N̲T̲E̲R̲F̲A̲C̲E̲S̲ 



   The rules and standards to be followed when implementing
   the different line circuits and interfaces for the
   MPF system will comply wit the standards described
   in IFB Part III annex 5D to 5H and 5K to 5N with reference
   to circuit characteristics and annex 5A, 5B, 5C and
   5I with reference to message formats and control.

   The line circuit standards to be followed will be the
   CCITT' recommendation V24 and V28.  All communication
   lines leaving the MPF area will be implemented with
   secure wires using low level signalling.

   The line transmission quality for dedicated lines and
   local user lines will be within the CCITT's Recommedations
   G.132 and G.133 - Orange Book, Vol. III, Geneva 76.

   The MPF subsystem exchange ACP127 and ACP126 messages
   with shore based commanders via the NICS TARE and TRC
   systems and with ship-borne commanders via the Ship-to-Shore,
   Broadcast and MR subsystems.  Service messages for
   communications control will be composed and dispatched
   automatically, as part of the message level protocols.



5.1  N̲I̲C̲S̲ ̲T̲A̲R̲E̲ 

   CR will, for the MPF subsystem, implement an interface
   to NICS TARE in accordance wth the Nato approved document
   "NICS TARE Interface", CPS/ICD/004 which is used for
   the CAMPS project.


         This interface document complies fully with Annex 5N
         of the IFB except for the following:

         -   CPS/ICD/004 defines both colocated and remote NICSTARE
             connections,  only the colocatd connection shall
             apply for Crossfox.

         -   CPS/ICD/004 defines ITA No. 5 as character code.
              CR will implement either ITA No. 2 or ITA No.
             5.  The decision as to which code shall be used
             will be made during the design phase.

         -   CPS/ICD/004 definesthe EDC link protocol document
             updated with DCN G2.  CR will implement the EDC
             link protocol in accordance with the referenced
             document, updated with DCN G9, dated 1 May 1981.



5.2      T̲A̲P̲E̲ ̲R̲E̲L̲A̲Y̲ ̲C̲E̲N̲T̲R̲E̲ ̲(̲T̲R̲C̲)̲

         The interface to TRC will be implemente in compliance
         with the requirements laid down in Annex 5D of the
         IFB.

         CR has implemented a TRC interface for the CAMPS system
         in accordance with the NATO approved document, "TRC,
         POINT-TO-POINT CONNECTION Interface", CPS/ICD/007,
         which complies ith Annex 5D.





5.3      B̲R̲O̲A̲D̲C̲A̲S̲T̲ ̲C̲I̲R̲C̲U̲I̲T̲ 

         The interface provided for the Broadcast circuits will
         have the following characteristics:

         a)  Physical Interface:

             -   The connection will be via a crypt/low speed
                 link.  The cryptos will be of type KW7, KW46T
                 or KW37T.

             -   The electrical interface will be in accordance
                 with the CCITT's recommandation V24/V28 low
                 level specification

             -   The MPF will control the synchronization of
                 the Crypto's usig V24 signals and special crypto
                 control equipment.

             -   The transmission will be asynchronous simplex
                 with baud rate of 75 bps.

             -   A seven bit character code will be used with
                 one start bit, five data bits, and one stop
                 bit.

             b)  F̲u̲n̲c̲t̲i̲o̲n̲a̲l̲ ̲I̲n̲t̲r̲f̲a̲c̲e̲

                 - The alphabet will be ITA No. 2

                 -   All messages transmitted will conform to
                     the applicable sections of ACP127 Supp.
                     1 and 3.

                 -   Messages related to maintenance and control
                     of the communication lines are either treated
                     by the supervsor manually or automatically
                     generated/analyzed automatically by the
                     MPF automatically.




5.4      S̲h̲i̲p̲-̲t̲o̲-̲S̲h̲o̲r̲e̲ ̲C̲i̲r̲c̲u̲i̲t̲s̲ 

         The interface provided for the Ship-to-Shore circuits
         will have the following characteristics:

         a)  Physical Interface:

             -   The connection will be vi a low speed crypto
                 (KW7) link.

             -   The electrical interface will be in accordance
                 with the CCITT's recommendation V24/V28 low
                 level specification.

             -   The transmission will be asynchronous simplex
                 with baud rate of 75 bps.

             -   A seven bit charater code will be used.

         b)  Functional Interface

             -   The alphabet will be ITA No. 2

             -   All messages received will be in either ACP127
                 format or ACP126 format.

             -   Messages related to maintenance and control
                 of the communication lines are laid d