|
DataMuseum.dkPresents historical artifacts from the history of: CP/M |
This is an automatic "excavation" of a thematic subset of
See our Wiki for more about CP/M Excavated with: AutoArchaeologist - Free & Open Source Software. |
top - metrics - download
Length: 61824 (0xf180) Types: RcTekst Names: »99109886.WP«
└─⟦dedaa6eab⟧ Bits:30005866/disk1.imd Dokumenter i RcTekst format (RCSL 99-1-*) └─⟦this⟧ »99109886.WP«
╱04002d4e0a00050000000002013b3140000000000000000000000000000000000000000000000000050a0f19232d373c555f6973ffffffff04╱ ↲ ↲ ACP750╞ ╞ ╞ ╞ ╞ Introduktion og↲ ╞ ╞ ╞ ╞ ╞ ╞ installation↲ Brugervejledning↲ ↲ ↲ ↲ ╞ ╞ ╞ ╞ ╞ ╞ ______________↲ ↲ ↲ ↲ ↲ ↲ ╞ ╞ ╞ ╞ ╞ ╞ Betjening↲ ↲ ↲ ↲ ↲ ↲ ╞ ╞ ╞ ╞ ╞ ╞ ______________↲ ↲ ↲ ↲ ↲ ┆06┆┆b0┆ACP750┆f0┆╞ ╞ Hvis noget↲ ┆06┆┆b0┆Brugervejledning┆f0┆╞ går galt↲ ↲ ↲ ↲ ↲ ↲ ╞ ╞ ╞ ╞ ╞ ╞ ______________↲ ↲ ↲ ↲ ↲ ╞ ╞ ╞ ╞ ╞ ╞ Reference del↲ ↲ ↲ ↲ ↲ ↲ ↲ ╞ ╞ ╞ ╞ ╞ ╞ ______________↲ ↲ ↲ ↲ ↲ ╞ ╞ ╞ ╞ ╞ ╞ Bilag↲ ↲ PN 991 09 886↲ ↲ ════════════════════════════════════════════════════════════════════════ ↓ Nøgleord:╞ ┆84┆ACP750, RC750,Partner, terminal, fil┄↓ ┆19┆┆8e┆┄┄overførsel, kom┄munikation. ↲ ↲ Resume┆88┆':╞ ┆84┆Denne vejledning beskriver installation og↲ ╞ ╞ ╞ ┆84┆betjening af ACP750.↲ ↲ Udgave:╞ ╞ August 1984↲ ↲ ↲ ↲ ↲ ↲ ↲ ↲ ↲ ↲ ↲ ↲ ↲ ↲ ↲ ↲ ↲ ↲ ↲ ↲ ↲ ↲ ↲ ↲ ↲ ↲ ↲ ↲ ↲ ↲ ↲ ↲ ╞ ╞ ╞ ┆84┆CCP/M-86 er et registreret varemærke fra ↓ ┆19┆┆8e┆┄┄Digital Research.↲ ↲ ↲ ════════════════════════════════════════════════════════════════════════ ↓ ┆15┆┆b3┆↲ ┆15┆┆b3┆┆a1┆┆b0┆_ _↲ ┆15┆┆b1┆┆b0┆A/S Regnecentralen┆05┆-┆0b┆-↲ ┆15┆┆b2┆┆b0┆-┆0b┆-┆05┆A/S Regnecentralen↲ ↲ ↲ ┆b0┆Indhold↲ ↲ ↲ 1. Introduktion ......................................┆05┆5↲ ↲ 2. Installation ......................................┆05┆7↲ 2.1 Pakkeindhold .................................┆05┆7↲ 2.2 Overførsel til systemdisk.....................┆05┆7↲ 2.2.1 Installation på diskette ..............┆05┆7↲ 2.2.2 Installation på winchester disk .......┆05┆8↲ 2.3 Konfigurering ................................┆05┆8↲ 2.3.1 Terminalemulering .....................┆05┆10↲ 2.3.2 Parametre for transmission ............┆05┆12↲ 2.3.3 Funktionstaster .......................┆05┆14↲ 2.3.4 Markør- og editeringstaster ...........┆05┆15↲ 2.4 Tilslutning til modem ........................┆05┆16↲ ↲ 3. Betjening .........................................┆05┆17↲ 3.1 Lokale kommandoer ............................┆05┆17↲ 3.1.1 Skærmkopi .............................┆05┆18↲ 3.1.2 Logning ...............................┆05┆18↲ 3.1.3 Send fil ..............................┆05┆19↲ 3.1.4 Modem signaler ........................┆05┆19↲ 3.2 Filoverførsel ................................┆05┆20↲ ↲ 4. Hvis noget går galt ...............................┆05┆21↲ 4.1 Fejl under opstart ...........................┆05┆21↲ 4.2 Kommunikation med værtsdatamat ...............┆05┆22↲ 4.3 Fejl ved drift ...............................┆05┆22↲ ↲ 5. Faciliteter ved RC851 terminalemulering ...........┆05┆25↲ 5.1 Styretegn ....................................┆05┆25↲ 5.2 Skærm-adressering ............................┆05┆29↲ ↲ 6. Faciliteter ved ADM3 terminalemulering.............┆05┆31↲ 6.1 Styretegn ....................................┆05┆31↲ 6.2 Skærm-adressering ............................┆05┆34↲ ↲ 7. Faciliteter ved ANSI terminalemulering ............┆05┆35↲ 7.1 Styretegn ....................................┆05┆35↲ 7.2 Styresekvenser ...............................┆05┆38↲ 7.3 Funktionstaster ..............................┆05┆46↲ ↲ 8. Faciliteter ved terminal i TEST tilstand ...........┆05┆49↲ ↲ ════════════════════════════════════════════════════════════════════════ ↓ A. Referencer ........................................┆05┆51↲ ↲ B. Oversigt over ANSI-X3.64, VT-100 og ACP-ANSI ......┆05┆52↲ ↲ C. ASCII tegnsæt .....................................┆05┆55↲ ↲ D. Lokale kommandoer i funktionstaster ...............┆05┆56↲ ↲ ↲ ┆14┆┆b1┆┆b0┆┆a1┆RC750┆05┆Indhold↲ ┆14┆┆b2┆┆b0┆┆a1┆Indhold┆05┆ACP750↲ ┆14┆┆b3┆↲ ↲ ┆14┆┆b1┆┆b0┆┆a1┆ACP750┆05┆1. Introduktion↲ ┆14┆┆b2┆┆b0┆┆a1┆1. Introduktion┆05┆ACP750↲ ┆14┆┆b3┆↲ ┆15┆┆b3┆↲ ┆15┆┆b3┆┆a1┆_ _↲ ┆15┆┆b1┆┆b0┆A/S Regnecentralen ┆05┆-┆0b┆-↲ ┆15┆┆b2┆┆b0┆-┆0b┆- ┆05┆A/S Regnecentralen↲ ↲ ┆b0┆1. Introduktion↲ ↲ ↲ Den asynkrone kommunikationspakke (ACP750) giver Partner ↓ mulighed for:↲ ↲ - ┆84┆At fungere som almindelig terminal, både mod RC-anlæg og ↓ ┆19┆┆83┆┄┄mod de fleste øvrige datamater, der er udstyret med ↓ ┆19┆┆83┆┄┄asynkron kommunikation.↲ ↲ - ┆84┆At fungere som avanceret terminal mod RC8000, der er i ↓ ┆19┆┆83┆┄┄stand til at overføre enkelte filer samt klumper af ↓ ┆19┆┆83┆┄┄filer mellem Partner og RC8000.↲ ↲ - ┆84┆At fungere som avanceret terminal mod værts-datamater, ↓ ┆19┆┆83┆┄┄der overholder ANSI X3.64 standarden for kommunikation ↓ ┆19┆┆83┆┄┄(se ref. (6)).↲ ↲ - ┆84┆At logge kommunikationen mellem værtsdatamat og Part┄ner, ↓ ┆19┆┆83┆┄┄enten til en skriver eller til en disk fil.↲ ↲ - ┆84┆At tage en kopi af skærmbilledet på et vilkårligt tids┄↓ ┆19┆┆83┆┄┄punkt, således at kopien kan anvendes f.eks. i for┄bind┄↓ ┆19┆┆83┆┄┄else med RcTekst.↲ ↲ I denne manual beskrives installation og betjening af ↓ ACP750 på Partner. Protokollen for filoverførsel i for┄bind┄↓ else med RC8000 er beskrevet i ref (3). Betjening af ↓ ACP8000 er beskrevet i ref (4).↲ ↲ ════════════════════════════════════════════════════════════════════════ ↓ ↲ ┆14┆┆b1┆┆b0┆┆a1┆ACP750┆05┆2. Installation↲ ┆14┆┆b2┆┆b0┆┆a1┆2. Installation┆05┆ACP750↲ ┆14┆┆b3┆↲ ┆15┆┆b3┆↲ ┆15┆┆b3┆┆a1┆_ _↲ ┆15┆┆b1┆┆b0┆A/S Regnecentralen ┆05┆-┆0b┆-↲ ┆15┆┆b2┆┆b0┆-┆0b┆- ┆05┆A/S Regnecentralen↲ ↲ ┆b0┆2. Installation↲ ↲ I dette kapitel beskrives hvorledes ACP750 installeres og ↓ konfigureres, samt hvilke kabler der anvendes ved tilslut┄↓ ning til modem.↲ ↲ ↲ ┆b0┆2.1 Pakkeindhold↲ ↲ Kommunikationspakken ACP750 leveres på en distributions┄↓ diskette, der indeholder følgende filer:↲ ↲ ╞ ACP.CMD ┆84┆ACP750 pro┄grammet.↲ ↲ ╞ ACP.CNF ┆84┆Konfigurationsfil for ACP750. Filen kan ↓ ┆19┆┆93┆┄┄oprettes/ændres med ACPKONF.↲ ↲ ╞ ACPKONF.CMD Konfigureringsprogram for ACP750.↲ ↲ ╞ INSTJOB.SUB ┆84┆Installations-job for overførsel af ↓ ┆19┆┆93┆┄┄ACP750 til en systemdisk.↲ ↲ ↲ ┆b0┆2.2 Overførsel til systemdisk↲ ↲ For at kunne anvende ACP750, kræves følgende filer:↲ ↲ ╞ ACP.CMD╞ der indeholder ACP750 programmet.↲ ╞ ACP.CNF╞ der indeholder den aktuelle konfigurering.↲ ↲ Endvidere bør konfigureringsprogrammet for ACP750, der ↓ findes i filen ACPKONF.CMD, findes på systemdisken.↲ ↲ De tre filer kan enten kopieres enkeltvis. f.eks. med 'Fil ↓ administration' fra hovedmenuen (se ref (1)) eller ved at ↓ anvende INSTJOB fra ACP750 distributionsdisketten som be┄↓ skrevet i 2.2.1 for RC750-3 og i 2.2.2 for RC750-4.↲ ↲ Når ACP750 er installeret, konfigureres som beskrevet i ↓ 2.3.↲ ↲ ↲ ┆b0┆2.2.1 Installation på diskette↲ ↲ ╞ - ┆84┆Start systemet på sædvanlig måde (system diskette i ↓ ┆19┆┆86┆┄┄A). Hvis der vises en menu, trykkes ESC for at komme ↓ ┆19┆┆86┆┄┄til CCP/M-86 kommando niveau.↲ ↲ ╞ - ┆84┆Indsæt ACP750 distributionsdisketten i diskette┄↓ ┆19┆┆86┆┄┄station B.↲ ↲ ┆8c┆┄┆ea┆↓ ╞ - ┆84┆Sæt aktuel disk til B ved at skrive:↲ ↲ ╞ ╞ A>┆b0┆B:↲ ╞ ╞ B>↲ ↲ ╞ - ┆84┆Overfør de 3 filer (nævnt ovenfor) til systemdisket┄↓ ┆19┆┆86┆┄┄ten i A ved at give følgende kommando til CCP/M-86:↲ ↲ ╞ ╞ B>┆b0┆SUBMIT INSTJOB A:↲ ↲ ↲ ┆b0┆2.2.2 Installation på winchester disk↲ ↲ ╞ - ┆84┆Start systemet på sædvanlig måde (winchester disk er ↓ ┆19┆┆86┆┄┄system disk). Hvis der vises en menu, trykkes ESC for ↓ ┆19┆┆86┆┄┄at komme til CCP/M-86 kommando niveau.↲ ↲ ╞ - ┆84┆Indsæt ACP750 distributionsdisketten i diskette┄↓ ┆19┆┆86┆┄┄station A.↲ ↲ ╞ - ┆84┆Sæt aktuel disk til A ved at skrive:↲ ↲ ╞ ╞ B>┆b0┆A:↲ ╞ ╞ A>↲ ↲ ╞ - ┆84┆Overfør de 3 filer (nævnt ovenfor) til winchester ↓ ┆19┆┆86┆┄┄disken (B) ved at give følgende kommando til CCP/M-↓ ┆19┆┆86┆┄┄86:↲ ↲ ╞ ╞ A>┆b0┆SUBMIT INSTJOB B:↲ ↲ ↲ ┆b0┆2.3 Konfigurering↲ ↲ Før ACP750 kan anvendes til kommunikation med en værts-↓ datamat - enten som almindelig terminal eller som avanceret ↓ terminal med filover┄førsel - skal ACP750 tilpasses værtens ↓ kommunikationsform. Tilpasningen, eller konfigureringen, ↓ foretages med program┄met ACPKONF, der udadtil virker lige┄↓ som programmet til konfigurering af systemparametrene på ↓ Partner (se ref (2)).↲ ↲ For at kunne konfigurere ACP750, er det nødvendigt at kende ↓ værts-datamatens kommunikations parametre (transmissions┄↓ hastighed/baud-rate, paritet mv.). I det følgende gives ↓ eksempler på tilpasning til RC8000 og ACP8000.↲ ↲ Parametrene til ACP750 findes i en separat fil, ACP750 ↓ læser efter opstart. De systemparametre, der er fastlagt ↓ ┆8c┆┄┆e2┆↓ ved hjælp af programmet KONFIG (se ref. (2)), har ingen ↓ ind┄flydelse på ACP750 - dette gælder dog ikke skærmpara┄↓ metrene (markørfremtræden og rulning), der bibeholdes ved ↓ opstart af ACP750.↲ ↲ Standardnavnet for filen med systemparametrene er ACP.CNF. ↓ I det følgende antages, at det er denne fil, der ændres ved ↓ konfigureringen af ACP750.↲ ↲ Programmet til konfigurering af ACP750 startes ved at ↓ skrive følgende kommando til CCP/M:↲ ↲ ╞ A>┆b0┆ACPKONF↲ ↲ Herefter fremkommer følgende menu på skærmen:↲ ↲ -- --↲ ACP750 Konfigurering version 2.0↲ -- --↲ ↲ H Hent konfigurering↲ ↲ G Gem konfigurering↲ ↲ T Terminal emulering↲ ↲ P Parametre for transmission↲ ↲ F Funktionstaster↲ ↲ M Markør- og editeringstaster↲ ↲ ↲ ↲ ↲ ↲ Tryk ESC for at returnere↲ -- --↲ ↲ ↲ Første trin i konfigureringen består i at hente en kon┄↓ figurering fra disken. Dette foretages ved at vælge punkt H ↓ - Hent konfigurering - i menuen ovenfor (tryk på tasten H). ↓ Herefter angives navnet på den konfigurering man ønsker at ↓ hente. Standardnavnet ACP (filens sekundærnavn skal ikke ↓ angives) vælges ved blot at trykke RETUR.↲ ↲ Konfigureringen kan nu ændres ved at vælge blandt de øvrige ↓ punkter (T, P, F og M) i menuen. Disse beskrives i de følg┄↓ ende afsnit.↲ ↲ ┆8c┆┄┆e6┆↓ Når alle ændringer er foretaget, vælges G - Gem konfigure┄↓ ring -, hvorefter navnet på den nu ændrede konfigurering ↓ angives. Trykkes RETUR, anvendes samme navn som angivet i ↓ punkt H.↲ ↲ ↲ ┆b0┆2.3.1 Terminal emulering↲ ↲ Her fastlægges, hvilken terminal ACP750 skal emulere. End┄↓ videre bestemmes, hvorledes bl.a. tabulering skal behand┄↓ les.↲ ↲ -- --↲ ACP750 Terminal emulering version 2.0↲ -- --↲ ↲ 1 Terminal type RC851↲ ↲ 2 Konvertering til store bogstaver nej↲ ↲ 3 Tabulatorstop hver n'te position 4↲ ↲ 4 Ekspandering af tab ved transmission nej↲ ↲ 5 A4 tast som break-tast nej↲ ↲ 6 Automatisk linieskift ja↲ ↲ 7 <LF> fortolkes som <LF>↲ ↲ 8 <FF> fortolkes som <FF>↲ ↲ 9 Terminal identifikation RC750 ACP V2.0↲ ↲ Tryk ESC for at returnere↲ -- --↲ ↲ ↲ (1) Terminal type.↲ Som terminaltype kan vælges mellem RC851, ADM3, ANSI og ↓ TEST. RC851 svarer stort set til RC822 og bør vælges ved ↓ kommunikation med RC8000. ANSI (ANSI X3.64-1979, se ref. ↓ (6)) er en amerikansk standard for terminaler, der bl.a. ↓ anvendes af VT100 terminalen fra DEC. VT100 har desuden ↓ nogle ekstra faciliteter, hvoraf de vigtigste er medtaget i ↓ ACP750's ANSI emulering. Vælges TEST, vil alle indkomne ↓ tegn, inclusive styretegn, vises på skærmen. Dette kan ↓ anvendes ved indkøring af nye systemer m.v.↲ ↲ ┆8c┆┄┆e2┆↓ Vælges en ny terminaltype, vil man blive spurgt, om markør┄↓ tasterne skal tilpasses den nye terminaltype. Svares nej, ↓ forbliver markørtasterne uændrede. Svares ja, indsættes de ↓ for den nye terminal relevante værdier. Se iøvrigt 2.3.4 ↓ for fastlæggelse af markørtasterne.↲ ↲ (2) Konvertering til store bogstaver.↲ Konvertering til store bogstaver kan være nødvendig, så┄↓ fremt værtsdatamaten ikke accepterer små bogstaver.↲ ↲ (3) Tabulatorstop hver n'te position.↲ Tabulatorstop sættes normalt altid til enten 4 eller 8. ↓ Værdien angiver afstanden mellem tabulatorstoppene. Vælges ↓ 4, er der stop i kolonne 4, 8, 12, 16 osv. op til 76.↲ ↲ (4) Ekspandering af tab ved transmis┄sion.↲ Denne facilitet bør normalt altid være slået fra og er kun ↓ medtaget af hensyn til værtsdatamater, der ikke forstår ↓ tab-tegnet. Ved ekspandering af tab anvendes samme tabula┄↓ tor-afstand som valgt ovenfor.↲ ↲ (5) A4 tast som break-tast.↲ A4-tasten kan anvendes som break tast, såfremt værts┄data┄↓ maten bruger break som "attention". Ved anvendelse af ↓ SKIFT┆1f┆+┆1f┆A4 sendes et "disconnect", der ved modem-↓ kommunikation afbryder forbindelsen.↲ ↲ (6) Automatisk linieskift.↲ Hvis der anvendes automatisk linieskift, vil markøren ↓ begynde på en ny linie, når der skrives ud over sidste ↓ position på linien.↲ ↲ (7) <LF> fortolkes som.↲ Styretegnet <LF> (Line-feed) giver normalt kun anledning ↓ til, at markøren flyttes een linie ned. Sender værts┄↓ datamaten kun et <LF> når der skiftes til en ny linie, kan ↓ ACP750 bringes til selv at flytte markøren til første ↓ position ved at vælge <CR><LF> (Carriage return + Line-↓ feed).↲ ↲ (8) <FF> fortolkes som.↲ Styretegnet <FF> (Form-feed) sletter normalt skærmen og ↓ flytter markøren til øverste, venstre hjørne af skærmen. ↓ Anvendes ACP750 til emulering af en VT100 terminal, sættes ↓ fortolkningen af <FF> til <LF> (Line-feed).↲ ↲ (9) Terminal identifikation.↲ Terminal identifikationen er den tekst, ACP750 sender til ↓ værtsdatamaten når denne beder om terminalens id. Dette ↓ ┆8c┆┄┆e2┆↓ sker f.eks. i forbindelse med styre-sekvensen DSR når ↓ ACP750 virker som ANSI terminal. Se iøvrigt 7.2.↲ ↲ ↲ ┆b0┆2.3.2 Parametre for transmission↲ ↲ Transmissions-parametrene for ACP750 fastlægges her - de ↓ parametre, der er specificeret med programmet KONFIG (se ↓ ref (2)), har ingen betydning for ACP750.↲ ↲ -- --↲ ACP750 Parametre for transmission version 2.0↲ -- --↲ ↲ 1 Modtage hastighed (baud) 1200↲ ↲ 2 Sende hastighed (baud) 1200↲ ↲ 3 Antal stopbit 2↲ ↲ 4 Antal bit pr. tegn 7↲ ↲ 5 Paritet lige↲ ↲ 6 Lokalt ekko nej↲ ↲ 7 Xon/Xoff protokol ja↲ ↲ 8 RTS/CTS protokol nej↲ ↲ 9 ACP filtransport protokol nej↲ ↲ Tryk ESC for at returnere↲ -- --↲ ↲ ↲ (1) og (2) Modtage og sendehastighed (baud).↲ Modtage- og sende-hastigheden vælges i baud. Man vil nor┄↓ malt altid anvende samme modtage- og sende-hastighed, ↓ typisk 300 eller 1200 baud ved modem-kommunikation og 1200 ↓ eller 4800 baud ved faste linier. Enkelte modemer er ind┄↓ rettet til at modtage og sende med forskellig hastighed. ↓ Her vil normalt være tale om at modtage med 1200 baud og ↓ sende med 75 baud.↲ ↲ (3) Antal stopbit.↲ Antallet af stopbit's afstemmes efter værtsdatamaten. ↓ Kendes dette ikke, kan værdien sættes til 2.↲ ↲ ┆8c┆┄┆e2┆↓ (4) Antal bit pr. tegn.↲ Ved næsten al kommunikation mellem en vært og en terminal, ↓ anvendes 7 bit pr. tegn. I enkelte tilfælde dog 8 bit pr. ↓ tegn.↲ ↲ (5) Paritet.↲ Pariteten anvendes ved kontrol af modtagne tegn (af vært og ↓ terminal).↲ ↲ (6) Lokalt ekko.↲ Lokalt ekko anvendes, såfremt værtsdatamaten ikke selv ↓ ekkoer indtastede tegn.↲ ↲ (7) Xon/Xoff protokol.↲ Xon/Xoff protokollen, der også benævnes DC1/DC3, skal altid ↓ anvendes, når der ønskes filtransport i forbindelse med ↓ ACP750. Bemærk at tegn fra tastaturet altid sendes, uanset ↓ om der er modtaget Xon fra værtsdatamaten.↲ ↲ (8) RTS/CTS protokol.↲ Anvendes RTS/CTS protokol, vil┄ ACP750 kun sende tegn, så┄↓ længe CTS-signalet er aktivt. Anvendes, hvis værtsdatamaten ↓ kræver dette.↲ ↲ (9) ACP filtransport protokol.↲ Ønskes filtransport mellem Partner og RC8000 ved hjælp af ↓ ACP8000, vælges denne facilitet her. Faciliteten kan ↓ frakobles af hensyn til værtsdatamater, der ikke kan ↓ anvende ACP filtransport protokollen.↲ ↲ Følgende værdier kan vælges for de enkelte parametre:↲ ↲ ╞ ┆84┆Sende- og modtage-hastighed (baud): 50, 75, 110, 150, ↓ ┆19┆┆84┆┄┄300, 600, 1200, 2400, 4800 eller 9600.↲ ↲ ╞ Antal stopbit: 1, 1,5 eller 2.↲ ↲ ╞ Antal bit pr. tegn: 5, 6, 7 eller 8.↲ ↲ ╞ Paritet: lige, ulige eller ingen.↲ ════════════════════════════════════════════════════════════════════════ ↓ ┆b0┆2.3.3 Funktionstaster↲ ↲ Her vælges de tegnsekvenser, der sendes, når en af funk┄↓ tionstasterne (F1 - F12) påvirkes. På menubilledet vises de ↓ aktuelle tegnsekvenser.↲ ↲ -- --↲ ACP750 Konfigurering version 2.0↲ -- --↲ ↲ F1 =↲ F2 =↲ F3 =↲ F4 =↲ F5 =↲ F6 =↲ F7 =↲ F8 =↲ F9 =↲ F10 =↲ F11 =↲ F12 =↲ ↲ ↲ Tryk på tasten der skal programmeres↲ Tryk ESC for at returnere↲ -- --↲ ↲ ↲ Styretegn repræsenteres ved tegnet ^, efterfulgt af det på┄↓ gældende styretegns hexadecimale tegnværdi. For eksempel ↓ vises RETUR, der har den hexadecimale tegnværdi 0D, som ↓ ^0D.↲ ↲ Hvis tegnsekvensen for en af tasterne skal ændres, nedtryk┄↓ kes den pågældene tast, hvorefter følgende tekst fremkom┄↓ mer:↲ ↲ ╞ ┆84┆Indtast den ønskede tegnsekvens (max 19 tegn)↲ ╞ - afslut med CTRL @↲ ↲ Herefter indtastes den ønskede tegnsekvens. Styretegn kan ↓ indlægges enten ved at trykke på den aktuelle tast, eller ↓ ved at taste ^, efterfulgt af tegnets hexadecimale værdi ↓ (to tegn). Styretegnet ESC indlægges ved at taste ^1B.↲ Når indtastningen er slut, holdes CTRL-tasten nede, hvor┄↓ efter der trykkes på @-tasten.↲ ↲ ┆8c┆┄┆e0┆↓ Det er muligt at lægge en serie af lokale kommandoer i en ↓ af funktionstasterne, således at f.eks. F1 åbner en fil, ↓ tager en kopi af skærmbilledet og derefter lukker filen ↓ igen. Dette kan bl.a. benyttes i forbindelse med RcTekst. ↓ Indlæggelse af lokale kommandoer er beskrevet i appendiks ↓ D.↲ ↲ ┆b0┆2.3.4 Markør- og editeringstaster↲ ↲ Her vælges de tegnsekvenser, der sendes, når en af markør- ↓ eller editeringstasterne påvirkes. På menubilledet vises de ↓ aktuelle tegnsekvenser.↲ ↲ -- --↲ ACP750 Markør- og editeringstaster version 2.0↲ -- --↲ ↲ = ^08↲ = ^18↲ = ^1A↲ = ^0A↲ = ^1D↲ Tegn ind =↲ Slet tegn =↲ ↲ ↲ ↲ ↲ ↲ ↲ ↲ ↲ Tryk på tasten der skal programmeres↲ Tryk ESC for at returnere↲ -- --↲ ↲ ↲ Ændring af de aktuelle tegnsekvenser foregår som beskrevet ↓ i foregående afsnit.↲ ↲ Tegnsekvenserne for markørtasterne indlægges normalt auto┄↓ matisk, når der vælges en ny terminaltype (se 2.3.1).↲ ↲ ════════════════════════════════════════════════════════════════════════ ↓ ┆b0┆2.4 Tilslutning til modem↲ ↲ Til forbindelsen mellem Partner og modem/værtsdatamat, ↓ anvendes et af følgende kabler:↲ ↲ Tilslutning til modem:↲ ╞ ╞ MF 120 (KBL 633 - 5m)↲ ╞ ╞ MF 121 (KBL 634 - 12m)↲ ╞ ╞ MF 122 (KBL 635 - 25m)↲ ↲ Tilslutning til RC886 (Current Loop Converter):↲ ╞ ╞ MF 123 (KBL 636 - 2,5m)↲ ↲ Tilslutning til RC700 (Piccolo):↲ ╞ ╞ CBL 912 (5m)↲ ╞ ╞ CBL 913 (12m)↲ ╞ ╞ CBL 914 (25m)↲ ↲ På Partner forbindes kablet til stikket mærket 'V.24 COMM' ↓ på bagsiden af centralenheden.↲ ┆14┆┆b1┆┆b0┆┆a1┆ACP750┆05┆3. Betjening↲ ┆14┆┆b2┆┆b0┆┆a1┆3. Betjening┆05┆ACP750↲ ┆14┆┆b3┆↲ ┆15┆┆b3┆↲ ┆15┆┆b3┆┆a1┆_ _↲ ┆15┆┆b1┆┆b0┆A/S Regnecentralen ┆05┆-┆0b┆-↲ ┆15┆┆b2┆┆b0┆-┆0b┆- ┆05┆A/S Regnecentralen↲ ↲ ┆b0┆3. Betjening↲ ↲ Opstart af ACP750 sker ved at give følgende kommando til ↓ CCP/M-86 (se ref. (1) for en beskrivelse af CCP/M-86):↲ ↲ ╞ A>┆b0┆ACP↲ ↲ ACP750 vil herefter slette skærmen og angive sin identifi┄↓ kation på skærmen. Når ACP750 er klar, står der 'ACP750' i ↓ statuslinien.↲ ↲ Findes konfigureringen ikke i den sædvanlige fil (ACP.CNF), ↓ angives primærnavnet på den pågældende fil, efter program┄↓ kaldet:↲ ↲ ╞ A>┆b0┆ACP MINKONF↲ ↲ ACP750 kan herefter anvendes som en almindelig terminal ↓ overfor værtsdatamaten.↲ ↲ ↲ ┆b0┆3.1 Lokale kommandoer↲ ↲ Udover anvendelse som almindelig terminal, findes på ACP750 ↓ nogle lokale kommandoer, der gør det muligt at tage en kopi ↓ af skærmbilledet - enten til en fil eller til en skriver, ↓ foretage logning af kommunikation med værtsdatamaten - også ↓ til en fil eller skriver, samt sende en tekstfil til værts┄↓ datamaten. Sidstnævnte to faciliteter gør det muligt, med ↓ lidt behændighed, at overføre filer mellem Partner og en ↓ værtsdatamat, selvom værtsdatamaten ikke er udstyret med ↓ ACP.↲ ↲ For at anvende de lokale kommandoer, trykkes på A1-tasten, ↓ hvorefter følgende linie erstatter statuslinien nederst på ↓ skærmen:↲ ↲ Afbryd acp, Log-enhed, Kopi-enhed, Send fil,↲ Modem signaler↲ ↲ ↲ For at vælge en af de fem muligheder, nedtrykkes bogstavet ↓ for det pågældene valg. RETUR-tasten betragtes som en 'for┄↓ trydelses-tast' dvs. der returneres fra den lokale kom┄mando ↓ tilstand.↲ ↲ Vælges A - Afbryd acp - afsluttes ACP750 og der returneres ↓ til styresystemet.↲ ↲ De øvrige lokale kommandoer beskrives i de følgende afsnit.↲ ↲ ════════════════════════════════════════════════════════════════════════ ↓ ┆b0┆3.1.1 Skærmkopi↲ ↲ En skærmkopi kan skrives enten til en fil eller til en ↓ skriver. Er det første gang, der tages en skærmkopi, vises ↓ følgende lokale kommandolinie:↲ ↲ Kopi enhed: Fil, Skriver↲ ↲ Vælges fil (F), vises følgende:↲ ↲ Filnavn:↲ ↲ Indtast herefter navnet på den fil, de efterfølgende skærm┄↓ kopier skal skrives til. Findes filen i forvejen, gives en ↓ advarsel inden filen overskrives.↲ ↲ Vælges skriver (S), vil efterfølgende skærmkopier blive ↓ sendt til skriveren.↲ ↲ Når kopi enheden er valgt, vises en af følgende lokale kom┄↓ mandolinier:↲ ↲ Kopi enhed: Tag skærmkopi, Luk skriver↲ Kopi enhed: Tag skærmkopi, Luk <filnavn>↲ ↲ For at tage en skærmkopi, tastes T, hvorefter der retur┄↓ neres til terminal-tilstanden igen med RETUR.↲ ↲ Ønsker man at skifte kopi enhed, skal den nuværende enhed ↓ først lukkes ved at taste L, når ovenstående lokale komman┄↓ dolinie vises.↲ ↲ ↲ ┆b0┆3.1.2 Logning↲ ↲ Som ved skærmkopiering, skal der også ved logning (slave┄↓ print) vælges en log-enhed. Også her kan der vælges mellem ↓ fil og skriver.↲ ↲ Bemærk: De to enheder skal være forskellige. Der kan ikke ↓ logges til skriver, samtidigt med at skriveren er valgt som ↓ kopi enhed.↲ ↲ ════════════════════════════════════════════════════════════════════════ ↓ Er logning slået fra, vises en af følgende lokale kommando┄↓ linier:↲ ↲ Log enhed: Begynd logning, Luk skriver↲ Log enhed: Begynd logning, Luk <filnavn>↲ ↲ Tryk B for at starte logning.↲ ↲ Er logning slået til, vises en af følgende lokale kommando┄↓ linier:↲ ↲ Log enhed: Afbryd logning, Luk skriver↲ Log enhed: Afbryd logning, Luk <filnavn>↲ ↲ ↲ ┆b0┆3.1.3 Send fil↲ ↲ Denne lokale kommando gør det muligt at sende en tekst-fil ↓ til værtsdatamaten. Navnet på tekst-filen angives, når ↓ ACP750 skriver:↲ ↲ Filnavn:↲ ↲ Når filnavnet er angivet, vises den lokale kommandolinie ↓ påny. Når der trykkes RETUR, slettes kommandolinien og ↓ transmissionen startes.↲ ↲ Filtransmission kan stoppes på et vilkårligt tidspunkt, ↓ blot ved at trykke på en tilfældig tast. Følgende lokale ↓ kommandolinie vil herefter fremkomme:↲ ↲ Stop fil send ? (j/n)↲ ↲ Svares j (ja) afbrydes transmissionen og filen lukkes.↲ ↲ Når hele filen er sendt, vises følgende lokale kommando┄↓ linie:↲ ↲ <filnavn> slut. Tryk RETUR↲ ↲ Når der trykkes RETUR, slettes kommandolinien og filen ↓ lukkes.↲ ↲ ↲ ┆b0┆3.1.4 Modem signaler↲ ↲ Denne lokale kommando viser de modtagne modem signalers↲ tilstand (DCD - Data Carrier Detect og CTS - Clear To ↓ Send). Er signalerne aktive (On), er forbindelsen til ↓ værten iorden og værten er klar.↲ ↲ ↲ ┆8c┆┄┆e8┆↓ ┆b0┆3.2 Filoverførsel med ACP↲ ↲ For at kunne overføre filer mellem Partner og RC8000, ↓ kræves, udover ACP750, værtsprogrammet ACP8000. Filover┄↓ førslen startes og kontrolleres med ACP8000, hvorfor der ↓ henvises til brugervejlednigen hertil (ref (4)).↲ ↲ Det skal bemærkes, at ACP8000 både kan overføre binære ↓ filer og tekst-filer. Opgave-filer fra RcTekst, der har ↓ filtypen WP, er binære filer og må ikke forsøges overført ↓ som tekst-filer.↲ ↲ ↲ ┆14┆┆b1┆┆b0┆┆a1┆ACP750┆05┆4. Hvis noget går galt↲ ┆14┆┆b2┆┆b0┆┆a1┆4. Hvis noget går galt┆05┆ACP750↲ ┆14┆┆b3┆↲ ┆15┆┆b3┆↲ ┆15┆┆b3┆┆a1┆_ _↲ ┆15┆┆b1┆┆b0┆A/S Regnecentralen ┆05┆-┆0b┆-↲ ┆15┆┆b2┆┆b0┆-┆0b┆- ┆05┆A/S Regnecentralen↲ ↲ ┆b0┆4. Hvis noget går galt↲ ↲ I dette kapitel beskrives de fejlsituationer, der kan opstå ↓ i forbindelse med brug af ACP750. Det understreges, at ↓ fejlmeddelelser fra værtsdatamaten, der udskrives på ↓ Partner, af gode grunde ikke kan beskrives herunder.↲ ↲ ↲ ┆b0┆4.1 Fejl ved opstart↲ ↲ Under opstart af ACP750 kan følgende fejlmeddelelser fore┄↓ komme:↲ ↲ For lidt lager↲ ↲ Der er ikke nok lager til at ACP750 kan oprette de ↓ nødvendige køer og buffere. ACP750 kræver ca. 60 k lager.↲ ↲ Kommunikationslinien er optaget af en anden konsol↲ ↲ Kommunikationslinien kan kun benyttes fra en af Partners ↓ 4 logiske konsoller ad gangen. Kan også skyldes, at ACP750 ↓ efter sidste brug ikke er korrekt afsluttet. Genstart ↓ maskinen (RESET) og prøv påny.↲ ↲ <filnavn> er ikke oprettet af ACPKONF↲ Fejl i <filnavn>↲ ↲ Disse fejlmeddelelser optræder, hvis konfigurerings┄filen ↓ for ACP750 (standard ACP.CNF) ikke har det for┄ventede ↓ indhold. Lav en ny fil med programmet ACPKONF (beskrevet i ↓ 2.3) og forsøg påny.↲ ↲ Kan ikke åbne <filnavn>↲ ↲ ACP750 kan ikke finde konfigureringsfilen. Filen ind┄læses, ↓ når intet andet er angivet, fra den aktuelle disk.↲ ↲ Fejl under initialisering↲ - kan ikke oprette/åbne kø: <navn>↲ - kan ikke oprette process: <navn>↲ ↲ Systemet tillader ikke ACP750 at oprette og åbne de nød┄↓ vendige køer og processer. Skyldes enten begræns┄ninger i ↓ system konfigurationen, eller at ACP750 efter sidste brug ↓ ikke er korrekt nedlukket. Genstart ma┄skinen (RESET) og ↓ prøv påny. I net-systemer kan årsagen være, at de ↓ nødvendige net-resourcer ikke er tilstede. Prøv at logge ↓ den aktuelle konsol fra (CCP/M-86 kommandoen LOGOFF) og ↓ genstart ACP.↲ ════════════════════════════════════════════════════════════════════════ ↓ ┆b0┆4.2 Kommunikation med værtsdatamat↲ ↲ Hvis man ikke kan komme i kontakt med værtsdatamaten, ↓ undersøges følgende:↲ ↲ ╞ - ┆84┆At der er anvendt et korrekt kabel mellem Partner og ↓ ┆19┆┆86┆┄┄modem/vært (se 2.4).↲ ↲ ╞ - ┆84┆At transmissionsparametrene for ACP750 passer til ↓ ┆19┆┆86┆┄┄værtsdatamaten.↲ ↲ Tabes der tegn ved udskrift på skærmen, kan det skyldes at ↓ Xon/Xoff er slået fra og at der anvendes en høj transmis┄↓ sionshastighed (9600 baud). Hvis værtsdatamaten ikke kan ↓ anvende Xon/Xoff, bør den bløde skærmrulning fjernes (se ↓ skærmtrimning, ref (1)).↲ ↲ Transmissionsfejl ved filoverførsel skyldes som regel, at ↓ der ikke anvendes Xon/Xoff protokol.↲ ↲ ↲ ┆b0┆4.3 Fejl ved drift↲ ↲ Opstår der en fejl i driftssituationen, udskriver ACP750 en ↓ af følgende fejlmeddelelser på øverste linie i skærmbil┄↓ ledet:↲ ↲ *** Kan ikke skrive til <filnavn>.↲ Logning afbrudt. Tryk RETUR↲ Skærmkopiering afbrudt. Tryk RETUR↲ ↲ Der er opstået en fejl under skrivning, enten til log-filen ↓ eller til kopi-filen, hvorefter den pågældende funktion er ↓ afbrudt. Fejlen kan skyldes, at der er fjernet en diskette ↓ eller at disketten/disken er fyldt op.↲ ↲ Skriver ikke ledig. Tryk RETUR↲ ↲ Skriveren kan kun anvendes til een funktion ad gangen. Luk ↓ altid skriveren (se 3.1) når den ikke benyttes.↲ ↲ <filnavn> eksisterer. Overskrives ? (j/n)↲ ↲ Der er valgt en eksisterende fil som enten log-enhed eller ↓ kopi-enhed. Betragtes kun som en advarsel, ikke en fejl. ↓ Svares ja, slettes den gamle fil.↲ ════════════════════════════════════════════════════════════════════════ ↓ Kan ikke slette <filnavn>. Tryk RETUR↲ ↲ Den valgte fil er beskyttet af CCP/M-86 og kan ikke ↓ slettes. Vælg et andet filnavn.↲ ↲ Kan ikke åbne <filnavn>. Tryk RETUR↲ ↲ Den valgte fil findes ikke.↲ ↲ ↲ ════════════════════════════════════════════════════════════════════════ ↓ ↲ ┆14┆┆b1┆┆b0┆┆a1┆ACP750┆05┆5. Faciliteter ved RC851 terminalemulering↲ ┆14┆┆b2┆┆b0┆┆a1┆5. Faciliteter ved RC851 terminalemulering┆05┆ACP750↲ ┆14┆┆b3┆↲ ┆15┆┆b3┆↲ ┆15┆┆b3┆┆a1┆_ _↲ ┆15┆┆b1┆┆b0┆A/S Regnecentralen ┆05┆-┆0b┆-↲ ┆15┆┆b2┆┆b0┆-┆0b┆- ┆05┆A/S Regnecentralen↲ ↲ ┆b0┆5. Faciliteter ved RC851 terminalemulering↲ ↲ ↲ RC851 terminalen er tilpasset programmel på RC8000 og giver ↓ mulighed for avanceret skærm-behandling, samt til- og fra-↓ kobling af en tilsluttet skriver (styret fra værten).↲ ↲ Udtrykket 'terminal' dækker i det følgende over en Partner ↓ + ACP750 programmet, 'vært' henviser til den værts-datamat ↓ terminalen er forbundet med.↲ ↲ ↲ ┆b0┆5.1 Styretegn↲ ↲ Ved gennemgang af styretegn, angives først forkortelsen ↓ (eks. CR), derefter den engelske betegnelse (eks. Carriage ↓ Return) og til slut styretegnets decimale værdi anført i ↓ <┆1f┆> (eks.┆1f┆<13>).↲ ↲ ↲ NUL↲ Null character↲ <00>↲ Ignoreres ved modtagelse og optager ikke bufferplads.↲ ↲ ↲ ETX↲ End of Text↲ <03>↲ Afslutter en blok eller kommando i ACP fil protokollen. ↓ Ignoreres hvis der ikke anvendes ACP fil protokol (ACPKONF ↓ parameter).↲ ↲ ↲ ENQ↲ Enquiry (Delete Line)↲ <05>↲ Sletter den aktuelle linie og flytter de efterfølgende ↓ linier en linie op.↲ ↲ ↲ ACK↲ Acknowledge (Cursor Position)↲ <06> kol lin↲ Flytter markøren til tegn-position kol, linie lin. Se 5.2 ↓ vedrørende kol og lin.↲ ↲ ↲ ════════════════════════════════════════════════════════════════════════ ↓ BEL↲ Bell↲ <07>↲ Giver et 'beep' fra konsollen.↲ ↲ ↲ BS↲ Backspace↲ <08>↲ Flytter markøren til foregående tegn-position. Markøren kan ↓ ikke flyttes længere end til position 1 på den aktuelle ↓ linie.↲ ↲ ↲ HT↲ Horizontal Tabulation↲ <09>↲ Flytter markøren frem til næste tabulator-stop. Markøren ↓ kan ikke flyttes ud over position 80 på den aktuelle linie.↲ ↲ ↲ LF↲ Line Feed↲ <10>↲ Flytter markøren en linie ned. Står markøren på sidste ↓ line, ruller skærm-billedet en linie op. Fortolkes LF som ↓ CR + LF (ACPKONF parameter, se 2.3.1), flyttes markøren til ↓ starten af den nye linie (tegn-position┆1f┆1).↲ ↲ ↲ FF↲ Form Feed↲ <12>↲ Sletter skærmen og placerer markøren i position 1,1. Kan ↓ alternativt fortolkes som LF (ACPKONF parameter, se 2.3.1).↲ ↲ ↲ CR↲ Carriage Return↲ <13>↲ Flytter markøren til starten af den aktuelle linie (tegn-↓ position 1).↲ ↲ ↲ DLE↲ Data Link Escape↲ <16>↲ Indleder en blok eller kommando i ACP fil protokollen. ↓ Ignoreres hvis der ikke anvendes ACP fil protokol (ACPKONF ↓ parameter, se 2.3.2).↲ ↲ ↲ ┆8c┆┄┆e8┆↓ DC1↲ Device Control character 1 - Xon↲ <17>↲ Sendes af vært eller terminal, når der igen kan modtages ↓ tegn (se DC3 nedenfor).↲ ↲ ↲ DC2↲ Device Control character 2↲ <18>↲ Starter logning til log-enhed. Er der ikke defineret en ↓ log-enhed (se lokale kommandoer, 3.1.2), åbnes skriveren ↓ som log-enhed. Er denne ikke ledig, vises en fejlmeddelelse ↓ på statuslinien. Er der åbnet en fil som log-enhed, skrives ↓ efterfølgende tegn til filen.↲ ↲ ↲ DC3↲ Device Control character 3 - Xoff↲ <19>↲ Sendes af vært eller terminal, når der ikke kan modtages ↓ tegn. Efterfølges af DC1, når afsenderen igen er klar til ↓ at modtage tegn. Kan frakobles som ACPKONF parameter (se ↓ 2.3.2).↲ ↲ ↲ DC4↲ Device Control character 4↲ <20>↲ Afbryder logning til log-enhed. Se beskrivelse af DC2 ↓ ovenfor.↲ ↲ ↲ CAN↲ Cancel (Cursor Forward)↲ <24>↲ Flytter markøren til næste tegn-position. Markøren kan ↓ ikke flyttes ud over linien.↲ ↲ ↲ EM↲ End of Medium↲ <25>↲ Afslutter en blok af tekst i ACP fil protokollen. Ignoreres ↓ hvis der ikke anvendes ACP fil protokol (ACPKONF ↓ parameter).↲ ↲ ↲ ════════════════════════════════════════════════════════════════════════ ↓ SUB↲ Substitute (Cursor Up)↲ <26>↲ Flytter markøren til foregående linie. Markøren kan ikke ↓ flyttes længere end til linie 1.↲ ↲ ↲ GS↲ Group Separator (Cursor Home)↲ <29>↲ Flytter markøren til position 1,1 (hjem).↲ ↲ ↲ RS↲ Record Separator (Erase to end of Line)↲ <30>↲ Overskriver den aktuelle linie med blanktegn fra den ↓ aktuelle position og frem (til tegn-position 80).↲ ↲ ↲ US↲ Unit Separator (Erase to end of Screen)↲ <31>↲ Overskriver skærmen med blanktegn fra den aktuelle position ↓ og frem (til position 24,80).↲ ↲ ↲ ════════════════════════════════════════════════════════════════════════ ↓ ┆b0┆5.2 Skærm-addressering↲ ↲ Ved flytning af markør sendes først ACK (<06>), derefter ↓ kolonne- og linie-nummer. De relevante værdier fremgår af ↓ nedenstående tabel (skærmens øverste venstre hjørne er ↓ position 1,1): ↲ ↲ Pos. Tegn Værdi Pos. Tegn Værdi Pos. Tegn Værdi↲ ↲ ╞ 1 <096> 28 æ <123> 55 V <086>↲ ╞ 2 a <097> 29 ø <124> 56 W <087>↲ ╞ 3 b <098> 30 å <125> 57 X <088>↲ ╞ 4 c <099> 31 ü <126> 58 Y <089>↲ ╞ 5 d <100> 32 <127> 59 Z <090>↲ ╞ 6 e <101> 33 @ <064> 60 Æ <091>↲ ╞ 7 f <102> 34 A <065> 61 Ø <092>↲ ╞ 8 g <103> 35 B <066> 62 Å <093>↲ ╞ 9 h <104> 36 C <067> 63 ^ <094>↲ ╞ 10 i <105> 37 D <068> 64 _ <095>↲ ╞ 11 j <106> 38 E <069> 65 <032>↲ ╞ 12 k <107> 39 F <070> 66 ! <033>↲ ╞ 13 l <108> 40 G <071> 67 " <034>↲ ╞ 14 m <109> 41 H <072> 68 # <035>↲ ╞ 15 n <110> 42 I <073> 69 $ <036>↲ ╞ 16 o <111> 43 J <074> 70 % <037>↲ ╞ 17 p <112> 44 K <075> 71 & <038>↲ ╞ 18 q <113> 45 L <076> 72 ' <039>↲ ╞ 19 r <114> 46 M <077> 73 ( <040>↲ ╞ 20 s <115> 47 N <078> 74 ) <041>↲ ╞ 21 t <116> 48 O <079> 75 * <042>↲ ╞ 22 u <117> 49 P <080> 76 + <043>↲ ╞ 23 v <118> 50 Q <081> 77 , <044>↲ ╞ 24 w <119> 51 R <082> 78 - <045>↲ ╞ 25 x <120> 52 S <083> 79 . <046>↲ ╞ 26 y <121> 53 T <084> 80 / <047>↲ ╞ 27 z <122> 54 U <085>↓ ════════════════════════════════════════════════════════════════════════ ↓ ↲ ┆b0┆↓ ┆14┆┆b1┆┆b0┆┆a1┆ACP750┆05┆6. Faciliteter ved ADM3 terminalemulering↲ ┆14┆┆b2┆┆b0┆┆a1┆6. Faciliteter ved ADM3 terminalemulering┆05┆ACP750↲ ┆14┆┆b3┆↲ ┆15┆┆b3┆↲ ┆15┆┆b3┆┆a1┆_ _↲ ┆15┆┆b1┆┆b0┆A/S Regnecentralen ┆05┆-┆0b┆-↲ ┆15┆┆b2┆┆b0┆-┆0b┆- ┆05┆A/S Regnecentralen↲ ↲ ┆b0┆6. Faciliteter ved ADM3 terminalemulering↲ ↲ ↲ ADM3 terminalen er en tty-terminal med mulighed for simpel ↓ skærm-behandling.↲ ↲ Udtrykket 'terminal' dækker i det følgende en Partner + ↓ ACP750 programmet, 'vært' henviser til den værts-datamat ↓ terminalen er forbundet med.↲ ↲ ↲ ┆b0┆6.1 Styretegn↲ ↲ Ved gennemgang af styretegn, angives først forkortelsen ↓ (eks. CR), derefter den engelske betegnelse (eks. Carriage ↓ Return) og til slut styretegnets decimale værdi anført i ↓ <┆1f┆> (eks.┆1f┆<13>).↲ ↲ ↲ NUL↲ Null character↲ <00>↲ Ignoreres ved modtagelse og optager ikke bufferplads.↲ ↲ ↲ ETX↲ End of Text↲ <03>↲ Afslutter en blok eller kommando i ACP fil protokollen. ↓ Ignoreres hvis der ikke anvendes ACP fil protokol (ACPKONF ↓ parameter).↲ ↲ ↲ BEL↲ Bell↲ <07>↲ Giver et 'beep' fra konsollen.↲ ↲ ↲ BS↲ Backspace↲ <08>↲ Flytter markøren til foregående tegn-position. Markøren kan ↓ ikke flyttes længere end til position 1 på den aktuelle ↓ linie.↲ ↲ ↲ ════════════════════════════════════════════════════════════════════════ ↓ HT↲ Horizontal Tabulation↲ <09>↲ Flytter markøren frem til næste tabulator-stop. Markøren ↓ kan ikke flyttes ud over position 80 på den aktuelle linie.↲ ↲ ↲ LF↲ Line Feed↲ <10>↲ Flytter markøren en linie ned. Står markøren på sidste ↓ line, ruller skærm-billedet en linie op. Fortolkes LF som ↓ CR + LF (ACPKONF parameter, se 2.3.1), flyttes markøren til ↓ starten af den nye linie (tegn-position┆1f┆1).↲ ↲ ↲ VT↲ Vertical Tabulation (Cursor Up)↲ <11>↲ Flytter markøren til foregående linie. Markøren kan ikke ↓ flyttes længere end til linie 1.↲ ↲ ↲ FF↲ Form Feed (Cursor Forward)↲ <12>↲ Flytter markøren til næste tegn-position. Markøren kan ikke ↓ flyttes ud over linien.↲ ↲ ↲ CR↲ Carriage Return↲ <13>↲ Flytter markøren til starten af den aktuelle linie (tegn-↓ position 1).↲ ↲ ↲ DLE↲ Data Link Escape↲ <16>↲ Indleder en blok eller kommando i ACP fil protokollen. ↓ Ignoreres hvis der ikke anvendes ACP fil protokol (ACPKONF ↓ parameter, se 2.3.2).↲ ↲ ↲ ════════════════════════════════════════════════════════════════════════ ↓ DC1↲ Device Control character 1 - Xon↲ <17>↲ Sendes af vært eller terminal, når der igen kan modtages ↓ tegn (se DC3 nedenfor).↲ ↲ ↲ DC3↲ Device Control character 3 - Xoff↲ <19>↲ Sendes af vært eller terminal, når der ikke kan modtages ↓ tegn. Efterfølges af DC1, når afsenderen igen er klar til ↓ at modtage tegn. Kan frakobles som ACPKONF parameter (se ↓ 2.3.2).↲ ↲ ↲ EM↲ End of Medium↲ <25>↲ Afslutter en blok af tekst i ACP fil protokollen. Ignoreres ↓ hvis der ikke anvendes ACP fil protokol (ACPKONF ↓ parameter).↲ ↲ ↲ SUB↲ Substitute (Clear Screen)↲ <26>↲ Sletter skærmen og placerer markøren i position 1,1. Kan ↓ alternativt fortolkes som LF (ACPKONF parameter, se 2.3.1).↲ ↲ ↲ ESC↲ Escape (Cursor Position)↲ <27> <61> kol lin↲ Flytter markøren til tegn-position kol, linie lin. Se 6.2 ↓ vedrørende kol og lin.↲ ↲ ↲ US↲ Unit Separator (Cursor Home)↲ <31>↲ Flytter markøren til position 1,1 (hjem).↲ ↲ ↲ ════════════════════════════════════════════════════════════════════════ ↓ ┆b0┆6.2 Skærm-addresering↲ ↲ Ved flytning af markør sendes først ESC (<27>), '=' (<61>), ↓ derefter kolonne- og linie-nummer. Til kolonne- og ↓ linienummeret adderes 31 (skærmens øverste venstre hjørne ↓ er position 1,1): ↲ ↲ Eksempel: Markør til kolonne 3, linie 6↲ ↲ ESC = " % <27> <61> <34> <37>↲ ↲ ↲ ┆14┆┆b1┆┆b0┆┆a1┆ACP750┆05┆7. Faciliteter ved ANSI terminalemulering↲ ┆14┆┆b2┆┆b0┆┆a1┆7. Faciliteter ved ANSI terminalemulering┆05┆ACP750↲ ┆14┆┆b3┆↲ ┆15┆┆b3┆↲ ┆15┆┆b3┆┆a1┆_ _↲ ┆15┆┆b1┆┆b0┆A/S Regnecentralen ┆05┆-┆0b┆-↲ ┆15┆┆b2┆┆b0┆-┆0b┆- ┆05┆A/S Regnecentralen↲ ↲ ┆b0┆7. Faciliteter ved ANSI terminalemulering↲ ↲ ↲ Med ACP750 som ANSI terminal, er det muligt at opnå en ↓ yderst avanceret form for skærm-behandling, idet værten har ↓ mulighed for at hente et skærmbillede, at programmere funk┄↓ tionstasterne samt at definere et vindue i skærm-billedet, ↓ hvori tekst kan udskrives rullende.↲ ↲ Udtrykket 'terminal' dækker i det følgende over en Partner ↓ + ACP750 programmet, 'vært' henviser til den værts-datamat ↓ terminalen er forbundet med.↲ ↲ Udover styretegnene, der gennemgås i det følgende afsnit, ↓ er der i ANSI-terminalen en lang række styresekvenser, som ↓ beskrives i afsnit 7.2.↲ ↲ ↲ ┆b0┆7.1 Styretegn↲ ↲ Ved gennemgang af styretegn, angives først forkortelsen ↓ (eks. CR), derefter den engelske betegnelse (eks. Carriage ↓ Return) og til slut styretegnets decimale værdi anført i ↓ <┆1f┆> (eks.┆1f┆<13>).↲ ↲ ↲ NUL↲ Null character↲ <00>↲ Ignoreres ved modtagelse og optager ikke bufferplads.↲ ↲ ↲ ETX↲ End of Text↲ <03>↲ Afslutter en blok eller kommando i ACP fil protokollen. ↓ Ignoreres hvis der ikke anvendes ACP fil protokol (ACPKONF ↓ parameter).↲ ↲ ↲ BEL↲ Bell↲ <07>↲ Giver et 'beep' fra konsollen.↲ ↲ ↲ BS↲ Backspace↲ <08>↲ Flytter markøren til foregående tegn-position. Markøren kan ↓ ikke flyttes længere end til position 1 på den aktuelle ↓ linie.↲ ↲ ↲ ┆8c┆┆81┆┆86┆↓ HT↲ Horizontal Tabulation↲ <09>↲ Flytter markøren frem til næste tabulator-stop. Markøren ↓ kan ikke flyttes ud over position 80 på den aktuelle linie.↲ ↲ ↲ LF↲ Line Feed↲ <10>↲ Flytter markøren en linie ned. Står markøren på sidste ↓ line, ruller skærm-billedet en linie op. Er der defineret ↓ et vindue (se STBM i 7.2), ruller skærm-billedet når ↓ markøren står på nederste linie i vinduet. Fortolkes LF som ↓ CR+LF (ACPKONF parameter (se 2.3.1) og SM/RM parameter) ↓ flyttes markøren til starten af den nye linie (tegn-↓ position┆1f┆1).↲ ↲ ↲ VT↲ Vertical Tabulation↲ <11>↲ Samme som LF (se ovenfor).↲ ↲ ↲ FF↲ Form Feed↲ <12>↲ Sletter skærmen og placerer markøren i position 1,1. Er ↓ terminalen i vindues-tilstand, placeres markøren i position ↓ 1,1 i vinduet. Kan alternativt fortolkes som LF (ACPKONF ↓ parameter, se 2.3.1), ved anvendelse som VT-100 terminal.↲ ↲ ↲ CR↲ Carriage Return↲ <13>↲ Flytter markøren til starten af den aktuelle linie (tegn-↓ position 1).↲ ↲ ↲ DLE↲ Data Link Escape↲ <16>↲ Indleder en blok eller kommando i ACP fil protokollen. ↓ Ignoreres hvis der ikke anvendes ACP fil protokol (ACPKONF ↓ parameter, se 2.3.2).↲ ↲ ↲ ┆8c┆┄┆e2┆↓ DC1↲ Device Control character 1 - Xon↲ <17>↲ Sendes af vært eller terminal, når der igen kan modtages ↓ tegn (se DC3 nedenfor).↲ ↲ ↲ DC3↲ Device Control character 3 - Xoff↲ <19>↲ Sendes af vært eller terminal, når der ikke kan modtages ↓ tegn. Efterfølges af DC1, når afsenderen igen er klar til ↓ at modtage tegn. Kan frakobles som ACPKONF parameter (se ↓ 2.3.2).↲ ↲ ↲ CAN↲ Cancel↲ <24>↲ Afbryder den aktuelle styresekvens.↲ ↲ ↲ EM↲ End of Medium↲ <25>↲ Afslutter en blok af tekst i ACP fil protokollen. Ignoreres ↓ hvis der ikke anvendes ACP fil protokol (ACPKONF ↓ parameter).↲ ↲ ↲ SUB↲ Substitute↲ <26>↲ Samme som CAN (se ovenfor).↲ ↲ ↲ ESC↲ Escape↲ <27>↲ Indleder en styresekvens (se 7.2). Såfremt styresekvensen ↓ ikke genkendes, ignoreres den.↲ ↲ ↲ ════════════════════════════════════════════════════════════════════════ ↓ ┆b0┆7.2 Styresekvenser↲ ↲ Styresekvenserne i ANSI indledes alle af enten ESC (<27>) ↓ eller CSI (<27> + <91>).↲ ↲ Er indledningen et ESC, følger umiddelbart efter et tegn, ↓ der bestemmer hvilken funktion der skal udføres. Disse ↓ sekvenser har ingen parametre.↲ ↲ Sekvenser indledt med CSI, efterfølges af eventuelle ↓ parametre, der altid angives på decimal form som ASCII ↓ ciffre ('0' til '9' (<48> til <57>)). Parametrene adskilles ↓ med tegnet ';' (<59>). Sekvensen afsluttes med et bogstav ↓ ('@' til 'ü' (<64> til <126>)), der angiver funktionen.↲ ↲ ↲ Ved gennemgang af styresekvenser, angives først ↓ forkortelsen (eks. CBT), derefter den engelske betegnelse ↓ (eks. Cursor Backward Tabulation) og til slut de enkelte ↓ elementer i styresekvensen.↲ ↲ Parametre til CSI sekvenser kan have følgende former:↲ ↲ Pn ┆84┆angiver en decimal værdi i et kontinuert interval.↲ Ps ┆84┆angiver en fast værdi, der har en af flere diskrete ↓ ┆19┆┆86┆┄┄værdier.↲ ↲ ↲ CBT↲ Cursor Backward Tabulation↲ CSI Pn Z↲ Flytter markøren Pn tabulator-stop mod venstre. Udelades ↓ Pn, flyttes til foregående tabulator-stop. Markøren kan ↓ ikke flyttes længere end til position 1 på den aktuelle ↓ linie.↲ ↲ ↲ CHT↲ Cursor Horizontal Tabulation↲ CSI Pn I↲ Flytter markøren Pn tabulator-stop mod højre. Udelades Pn, ↓ flyttes til næste tabulator-stop. Markøren kan ikke flyttes ↓ længere end til position 80 på den aktuelle linie.↲ ↲ ↲ ════════════════════════════════════════════════════════════════════════ ↓ CPR↲ Cursor Position Report↲ CSI Pn1 ; Pn2 R↲ Svar på DSR (parameter 6) om markørens aktuelle position. ↓ Pn1 angiver den aktuelle linie, Pn2 tegn-positionen. Er ↓ terminalen i vindues-tilstand, angiver Pn1 det relative ↓ linie-nummer.↲ ↲ ↲ CSI↲ Control Sequence Introducer↲ ESC Æ↲ Angiver starten på en CSI styresekvens.↲ ↲ ↲ CUB↲ Cursor Backward↲ CSI Pn D↲ Flytter markøren Pn tegn-positioner mod venstre. Udelades ↓ Pn, flyttes til foregående tegn-position. Markøren kan ikke ↓ flyttes længere end til position 1 på den aktuelle linie.↲ ↲ ↲ CUD↲ Cursor Down↲ CSI Pn B↲ Flytter markøren Pn linier ned. Udelades Pn, flyttes til ↓ næste linie. Markøren kan ikke flyttes længere end til ↓ linie 24. Er der defineret et vindue, kan markøren ikke ↓ flyttes forbi sidste linie i vinduet.↲ ↲ ↲ CUF↲ Cursor Forward↲ CSI Pn C↲ Flytter markøren Pn tegn-positioner mod højre. Udelades Pn, ↓ flyttes til næste tegn-position. Markøren kan ikke flyttes ↓ længere end til position 80 på den aktuelle linie.↲ ↲ ↲ CUP↲ Cursor Position↲ CSI Pn1 ; Pn2 H↲ Flytter markøren til linie Pn1, position Pn2. Udelades Pn1 ↓ og Pn2, flyttes til position 1,1. Er terminalen i vindues-↓ tilstand, flyttes markøren relativt i forhold til det ↓ definerede vindue.↲ ↲ ↲ ┆8c┆┄┆e2┆↓ CUU↲ Cursor Up↲ CSI Pn A↲ Flytter markøren Pn linier op. Udelades Pn, flyttes til ↓ foregående linie. Markøren kan ikke flyttes længere end til ↓ linie 1. Er der defineret et vindue, kan markøren ikke ↓ flyttes forbi første linie i vinduet.↲ ↲ ↲ DA↲ Device Attributes↲ CSI Pn c↲ Spørgsmål og svar i forbindelse med identifikation af ↓ terminalen.↲ Pn = 0 ┆84┆er et krav til terminalen om at sende sin ↓ ┆19┆┆87┆┄┄identifikation.↲ Pn > 0 er svar fra terminalen. ACP750 svarer med:↲ CSI ? 1 ; 0 c↲ ↲ ↲ DCH↲ Delete Character↲ CSI Pn P↲ Sletter Pn tegn fra den aktuelle tegn-position og frem. De ↓ efterfølgende tegn flyttes mod venstre til den aktuelle ↓ tegn-position. Udelades Pn, slettes tegnet i den aktuelle ↓ position. Der kan ikke slettes ud over linien.↲ ↲ ↲ DCS↲ Device Control String↲ ESC P↲ Markerer starten på en tal-streng, der anvendes ved ↓ programmering af funktionstasterne. Strengen afsluttes af ↓ ST. Programmering af funktions-tasterne er beskrevet i ↓ 7.3.↲ ↲ ↲ DL↲ Delete Line↲ CSI Pn M↲ Sletter Pn linier fra den aktuelle linie og ned. De ↓ efterfølgende linier flyttes op til den aktuelle linie-↓ position. Udelades Pn, slettes den aktuelle linie. Er ↓ terminalen i vindues-tilstand, flyttes kun linier indefor ↓ vinduet.↲ ↲ ↲ ════════════════════════════════════════════════════════════════════════ ↓ DMI↲ Disable Manual Input↲ ESC↲ Spærrer tastaturet, således at der ikke kan sendes tegn fra ↓ terminalen.↲ ↲ ↲ DSR↲ Device Status Report↲ CSI Ps n↲ Spørgsmål og svar i forbindelse med terminalens aktuelle ↓ tilstand.↲ Ps = 0 ┆84┆er et svar fra terminalen om, at den er klar.↲ Ps = 5 medfører, at terminalen sender førnævnte svar.↲ Ps = 6 ┆84┆medfører, at terminalen sender den aktuelle markør-↓ ┆19┆┆87┆┄┄position i form af en CPR sekvens.↲ ↲ ↲ ECH↲ Erase Character↲ CSI Pn X↲ Overskriver Pn tegn fra den aktuelle tegn-position og frem ↓ med blank-tegn. Udelades Pn, overskrives tegnet i den ↓ aktuelle position. Der kan ikke overskrives ud over linien.↲ ↲ ↲ ED↲ Erase in Display↲ CSI Ps J↲ Overskriver tegn på skærm-billedet med blanktegn, afhængig ↓ af Ps. Udelades Ps, antages Ps = 0. Markørens position ↓ ændres ikke.↲ Ps = 0 ┆84┆overskriver fra den aktuelle position (incl.) til ↓ ┆19┆┆87┆┄┄position 24,80.↲ Ps = 1 ┆84┆overskriver fra position 1,1 til den aktuelle ↓ ┆19┆┆87┆┄┄position (incl.).↲ Ps = 3 overskriver hele skærmen-billedet. ↲ ↲ EL↲ Erase in line↲ CSI Ps K↲ Overskriver tegn på den aktuelle linie med blanktegn, ↓ afhængig af Ps. Udelades Ps, antages Ps = 0. Markørens ↓ position ændres ikke.↲ Ps = 0 ┆84┆overskriver fra den aktuelle position (incl.) til ↓ ┆19┆┆87┆┄┄tegn-position 80 på den aktuelle linie.↲ Ps = 1 ┆84┆overskriver fra tegn-position 1 på linien til den ↓ ┆19┆┆87┆┄┄aktuelle position (incl.).↲ Ps = 3 overskriver hele den aktuelle linie.↲ ↲ ↲ ┆8c┆┄┆e6┆↓ EMI↲ Enable Manual Input↲ ESC b↲ Tillader terminalen at sende tegn fra tastaturet.↲ ↲ ↲ HPR↲ Horizontal Position Relative↲ CSI Pn a↲ Samme som CUF (se ovenfor).↲ ↲ ↲ HTS↲ Horizontal Tabulation Set↲ ESC H↲ Sætter et tabulator-stop i den aktuelle tegn-position.↲ ↲ ↲ HVP↲ Horizontal and Vertical Position↲ CSI Pn1 ; Pn2 f↲ Samme som CUP (se ovenfor).↲ ↲ ↲ ICH↲ Insert Character↲ CSI Pn @↲ Indsætter Pn blank-tegn fra den aktuelle tegn-position og ↓ frem. Eventuelle tegn flyttes mod venstre, for at give ↓ plads til blank-tegnene. Udelades Pn, indsættes 1 blank-↓ tegn. Flyttes tegn ud over linien, tabes de.↲ ↲ ↲ ID↲ Identify Terminal↲ ESC Z↲ Krav til terminalen om at sende sin identifikation. Samme ↓ som DA med parametren 0.↲ ↲ ↲ IL↲ Insert Line↲ CSI Pn L↲ Indsætter Pn linier fra den aktuelle linie-position. Den ↓ aktuelle linie og linierne fremefter flyttes ned. Udelades ↓ Pn, indsættes 1 linie. Er terminalen i vindues-tilstand, ↓ flyttes kun linier indenfor vinduet.↲ ↲ ↲ ════════════════════════════════════════════════════════════════════════ ↓ IND↲ Index↲ ESC D↲ Flytter markøren en linie ned. Står markøren på den sidste ↓ linie, ruller skærm-billedet en linie op og markøren bliver ↓ stående. Er der defineret et vindue, vil skærmbilledet ↓ rulle når markøren står på sidste linie i vinduet.↲ ↲ ↲ MC↲ Media Copy↲ CSI Ps i↲ Anvendes til styring af skriver m.v.↲ Ps = 0 ┆84┆kopierer skærm-billedet til kopi-enheden. Er kopi-↓ ┆19┆┆87┆┄┄enheden ikke åben, anvendes skriveren som kopi-↓ ┆19┆┆87┆┄┄enhed.↲ Ps = 6 ┆84┆starter logning til log-enheden. Er log-enheden ikke ↓ ┆19┆┆87┆┄┄åben, anvendes skriveren som log-enhed.↲ Ps = 7 stopper logning til log-enheden.↲ Ps = 8 ┆84┆sender skærm-billedet. Først sendes DCS, derefter ↓ ┆19┆┆87┆┄┄24┆1f┆*┆1f┆80 tegn afsluttet med ST.↲ ↲ ↲ NEL↲ Next Line↲ ESC E↲ Flytter markøren til første position på næste linie. Står ↓ markøren på den sidste linie, ruller skærm-billedet en ↓ linie op og markøren flyttes til første position på linien. ↓ Er der defineret et vindue, ruller skærm-billedet når ↓ markøren står på sidste linie i vinduet.↲ ↲ ↲ RC↲ Restore Cursor↲ ESC 8↲ Flytter markøren tilbage til den gemte position (se SC) og ↓ sætter de gemte tegn-attributter.↲ ↲ ↲ RI↲ Reverse Index↲ ESC M↲ Flytter markøren en linie op. Står markøren på første ↓ linie, ruller skærmen en linie ned og markøren bliver ↓ stående. Er der defineret et vindue, ruller skærm-billdet ↓ når markøren står på første linie i vinduet.↲ ↲ ↲ ┆8c┆┄┆e2┆↓ RIS↲ Reset to Initial State↲ ESC c↲ Sletter skærm-billedet, fjerner alle attributter, flytter ↓ markøren til position 1,1 og re-initialiserer evt. ↓ tabulator-stop. Hvis der anvendes Xon/Xoff protokol, sendes ↓ et Xon.↲ ↲ ↲ RM↲ Reset Mode↲ CSI Ps l↲ Frigør terminalen fra en tidligere sat tilstand.↲ Ps = 2 ┆84┆tillader terminalen at sende tegn fra tastaturet.↲ Ps = 20 ┆84┆efterfølgende LF styretegn fortolkes som IND.↲ Ps = 36 ┆84┆markøren bliver i position 80, når linien er fuld ↓ ┆19┆┆88┆┄┄d.v.s. der skiftes ikke automatisk til ny linie.↲ Ps = 37 ┆84┆frigør terminalen fra vindues-tilstand. Indfører ↓ ┆19┆┆88┆┄┄absolut markør-addressering, hvorefter markøren ↓ ┆19┆┆88┆┄┄flyttes til position 1,1 (øverste venstre hørne af ↓ ┆19┆┆88┆┄┄skærm-billedet). Markøren kan flyttes over hele ↓ ┆19┆┆88┆┄┄skærm-billedet.↲ ↲ Ps = ?7 svarer til 36 (VT100 kompatibel).↲ Ps = ?6 svarer til 37 (VT100 kompatibel).↲ ↲ ↲ SC↲ Save Cursor↲ ESC 7↲ Gemmer den aktuelle markør-position til brug ved en ↓ efterfølgende RM. Desuden gemmes de aktuelle tegn-↓ attributter.↲ ↲ ↲ SGR↲ Select Graphic Rendition↲ CSI Ps m↲ Fastlægger nye tegn-attributter, der er gældende for ↓ efterfølgende tegn.↲ Ps = 0 ┆84┆fjerner alle attributter.↲ Ps = 1 sætter fremhævet skrift.↲ Ps = 2 sætter dæmpet skrift.↲ Ps = 4 sætter understregning↲ Ps = 5 sætter blink↲ Ps = 6 som 5↲ Ps = 7 sætter invers skrift↲ ↲ ↲ ┆8c┆┄┆e2┆↓ SM↲ Set Mode↲ CSI Ps h↲ Sætter en eller flere terminal-tilstande.↲ Ps = 2 ┆84┆spærrer tastaturet, således at der ikke kan sendes ↓ ┆19┆┆88┆┄┄tegn fra tastaturet.↲ Ps = 20 ┆84┆efterfølgende LF styre-tegn fortolkes som NEL↲ Ps = 36 ┆84┆markøren flyttes til en ny linie, når den aktuelle ↓ ┆19┆┆88┆┄┄linie er fuld.↲ Ps = 37 ┆84┆sætter terminalen i vindues-tilstand. Indfører ↓ ┆19┆┆88┆┄┄relativ markør-addressering, hvorefter markøren ↓ ┆19┆┆88┆┄┄flyttes til position 1,1 (øverste venstre hjørne af ↓ ┆19┆┆88┆┄┄vinduet). Markøren kan ikke flyttes udenfor ↓ ┆19┆┆88┆┄┄vinduet.↲ Ps = ?7 svarer til 36 (VT100 kompatibel).↲ Ps = ?6 svarer til 37 (VT100 kompatibel).↲ ↲ ↲ ST↲ String Terminator↲ ESC Ø↲ Markerer afslutningen på en tegn-streng. Anvendes bl.a. ved ↓ programmering af funktionstaster (DCS) og når terminalen ↓ sender svar (MC).↲ ↲ ↲ STBM↲ Set Top and Bottom Margen↲ CSI Pn1 ; Pn2 r↲ Fastlægger et vindue i skærm-billdet, hvor første linie er ↓ Pn1, sidste Pn2. Pn2 skal være større end Pn1 d.v.s. ↓ vinduet består mindst af 2 linier. Markøren flyttes til ↓ position 1,1, der er øverste venstre hjørne af skærm-↓ billedet når terminalen ikke er i vindues-tilstand; øverste ↓ venstre hjørne af vinduet i vindues-tilstand. Når markøren ↓ står på en vindues-grænse, ruller linierne i vinduet. Ved ↓ at udelade Pn1 og Pn2, fjernes et tidligere defineret ↓ vindue.↲ ↲ ↲ SU↲ Scroll Up↲ CSI Pn S↲ Ruller skærmen Pn liner op. Udelades Pn, rulles en linie ↓ op. Er der defineret et vindue, rulles kun linierne indefor ↓ vinduet.↲ ↲ ↲ ════════════════════════════════════════════════════════════════════════ ↓ TBC↲ Tabulation Clear↲ CSI Ps g↲ Sletter tabulator-stop, afhængigt af Ps. Udelades Ps, ↓ antages Ps = 0.↲ Ps = 0 ┆84┆Sletter et evt. tabulator-stop i den aktuelle tegn-↓ ┆19┆┆87┆┄┄position.↲ Ps = 2 samme som 0↲ Ps = 3 sletter alle tabulator-stop.↲ ↲ ↲ 7.3 Funktionstaster↲ ↲ Samtlige programmerbare funktionstaster på Partner (se ref ↓ (1) og (2)) kan programmeres fra værten.↲ ↲ Ved programmering sendes først en DCS sekvens (se 7.2), ↓ derefter koden for den pågældende funktionstast efterfulgt ↓ af de tegn, der skal indsættes. Der afsluttes med en ST ↓ sekvens (se 7.2). Tast-koden og tegnene angives med to ↓ ciffre på hexadecimal form.↲ ↲ Koden for funktionstasterne fremgår af efterfølgende tabel:↲ ↲ Tast Kode SKIFT CTRL ALT↲ ↲ F1╞ ╞ 3B╞ 6B╞ 75╞ 61↲ F2╞ ╞ 3C╞ 6C╞ 76╞ 62↲ F3╞ ╞ 3D╞ 6D╞ 77╞ 63↲ F4╞ ╞ 3E╞ 6E╞ 78╞ 64↲ F5╞ ╞ 3F╞ 6F╞ 79╞ 65↲ F6╞ ╞ 40╞ 70╞ 7A╞ 66↲ F7╞ ╞ 41╞ 71╞ 7B╞ 67↲ F8╞ ╞ 42╞ 72╞ 7C╞ 68↲ F9╞ ╞ 43╞ 73╞ 7D╞ 69↲ F10╞ ╞ 44╞ 74╞ 7E╞ 6A↲ F11╞ ╞ 45╞ 5B╞ 5D╞ 59↲ F12╞ ╞ 46╞ 5C╞ 5E╞ 5A↲ Pil hjem╞ 47↲ Pil op╞ ╞ 48↲ Pil venstre╞ 4B↲ Pil højre╞ 4D↲ Pil ned╞ 50↲ Num. RETUR╞ 4C↲ Num. TAB╞ 51↲ TEGN IND╞ 52↲ SLET TEGN╞ 53↲ PRINT╞ ╞ 54↲ ↲ ┆8c┆┄┆e2┆↓ Funktionstasterne F1 - F12 kan indeholde op til 19 tegn. De ↓ øvrige taster (markør- og editeringstaster samt F1 - F12 ↓ med SKIFT, CTRL eller ALT), kan indeholde 4 tegn.↲ ↲ Eksempel 1: ┆84┆F1 sættes til teksten 'Partner' efterfulgt af ↓ ┆19┆┆8d┆┄┄CR (Carriage Return).↲ ↲ Tegn ╞ Værdi (dec)╞ Betydning↲ ↲ ESC P╞ ╞ <27> <80>╞ ╞ DCS (start mærke)↲ 3 B╞ ╞ <51> <66>╞ ╞ Tast F1 (kode)↲ 5 0╞ ╞ <53> <48>╞ ╞ Bogstavet 'P'↲ 6 1╞ ╞ <54> <49>╞ ╞ - 'a'↲ 7 2╞ ╞ <55> <50>╞ ╞ - 'r'↲ 7 4╞ ╞ <55> <52>╞ ╞ - 't'↲ 6 E╞ ╞ <54> <69>╞ ╞ - 'n'↲ 6 5╞ ╞ <54> <53>╞ ╞ - 'e'↲ 7 2╞ ╞ <55> <50>╞ ╞ - 'r'↲ 0 D╞ ╞ <48> <68>╞ ╞ CR (Carriage Return)↲ ESC Ø╞ ╞ <27> <92>╞ ╞ ST (slut mærke)↲ ↲ Følgende ASCII-tegn sendes:↲ ↲ ┆b0┆ESC P 3 B 5 0 6 1 7 2 7 4 6 E 6 5 7 2 0 D ESC Ø↲ ↲ Mellemrum er kun indsat af hensyn til overskueligheden. ESC ↓ betyder at styretegnet ESC (<27>) sendes.↲ ↲ ↲ Eksempel 2: ┆84┆SKIFT F12 sættes til CR + LF (Carriage Return ↓ ┆19┆┆8d┆┄┄+ Line Feed).↲ ↲ Tegn ╞ Værdi (dec)╞ Betydning↲ ↲ ESC P╞ ╞ <27> <80>╞ ╞ DCS (start mærke)↲ 5 C╞ ╞ <53> <67>╞ ╞ SHIFT F12 (kode)↲ 0 D╞ ╞ <48> <68>╞ ╞ CR (Carriage Return)↲ 0 A╞ ╞ <48> <65>╞ ╞ LF (Line Feed)↲ ESC Ø╞ ╞ <27> <92>╞ ╞ ST (slut mærke)↲ ↲ Følgende ASCII-tegn sendes:↲ ↲ ┆b0┆ESC P 5 C 0 D 0 A ESC Ø↲ ↲ ════════════════════════════════════════════════════════════════════════ ↓ ↲ ↲ ┆14┆┆b1┆┆b0┆┆a1┆ACP750┆05┆8. Faciliteter ved terminal i TEST tilstand↲ ┆14┆┆b2┆┆b0┆┆a1┆8. Faciliteter ved terminal i TEST tilstand┆05┆ACP750↲ ┆14┆┆b3┆↲ ┆15┆┆b3┆↲ ┆15┆┆b3┆┆a1┆_ _↲ ┆15┆┆b1┆┆b0┆A/S Regnecentralen ┆05┆-┆0b┆-↲ ┆15┆┆b2┆┆b0┆-┆0b┆- ┆05┆A/S Regnecentralen↲ ↲ ┆b0┆8. Faciliteter ved terminal i TEST tilstand↲ ↲ ↲ Er der problemer i forbindelse med kommunikationen med en ↓ vært, kan ACP750 anvendes til kontrol af hvilke tegn, ↓ værten sender til terminalen. TEST kan vælges som en ↓ terminaltype med ACPKONF, se 2.3.1.↲ ↲ Tegn med grafisk repræsentation (<32> - <126>) vises på ↓ sædvanlig vis, hvorimod styretegn vises understreget og med ↓ deres ASCII betegnelse (eks. vises <13> som ┆a1┆CR┆e1┆). Tegn fra ↓ det udvidede tegnsæt (<127> - <255>), vises på decimal ↓ form, understreget og indsluttet i <> (eks. vises <255> som ↓ ┆a1┆<255>┆e1┆).↲ ↲ Indtastede tegn fra tasturet sendes på normal vis. Xon/Xoff ↓ og ACP fil protokol er altid slået fra.↲ ↲ Tabellen i appendiks C giver en oversigt over tegnsættet ↓ samt tegn-værdierne på decimal og hexadecimal form.↲ ↲ ════════════════════════════════════════════════════════════════════════ ↓ ↲ ↓ ┆14┆┆b1┆┆b0┆┆a1┆ACP750┆05┆A. Referencer↲ ┆14┆┆b2┆┆b0┆┆a1┆A. Referencer┆05┆ACP750↲ ┆14┆┆b3┆↲ ┆15┆┆b3┆↲ ┆15┆┆b3┆┆a1┆_ _↲ ┆15┆┆b1┆┆b0┆A/S Regnecentralen ┆05┆-┆0b┆-↲ ┆15┆┆b2┆┆b0┆-┆0b┆- ┆05┆A/S Regnecentralen↲ ↲ ┆b0┆A. Referencer↲ ↲ ↲ (1) SW1500D↲ Partner↲ Brugervejledning↲ Betjening↲ ↲ (2) SW1500D↲ Partner↲ Brugervejledning↲ Installation og vedligeholdelse↲ ↲ (3) RCSL 42-i2498↲ Asynkron kommunikations protokol (ACP)↲ Protokol beskrivelse↲ ↲ (4) RCSL 31-D713↲ RC8000 Asynkron kommunikations pakke (ACP8000)↲ Brugervejledning↲ ↲ (5) SW1730D↲ RC700 Asynkron kommunikations pakke (ACP700)↲ Brugervejledning↲ ↲ (6) ANSI X3.64-1979↲ Additional Controls for use with American National↲ Standard Code for information interchange↲ American National Standard Institute inc.↲ 1430 Broadway↲ New York 10018↲ ↲ ↓ ┆14┆┆b1┆┆b0┆┆a1┆ACP750┆05┆B. Oversigt over ANSI-X3.64, VT-100 og ACP-ANSI↲ ┆14┆┆b2┆┆b0┆┆a1┆B. Oversigt over ANSI-X3.64, VT-100 og ACP-ANSI┆05┆ACP750↲ ┆14┆┆b3┆↲ ┆15┆┆b3┆↲ ┆15┆┆b3┆┆a1┆_ _↲ ┆15┆┆b1┆┆b0┆A/S Regnecentralen ┆05┆-┆0b┆-↲ ┆15┆┆b2┆┆b0┆-┆0b┆- ┆05┆A/S Regnecentralen↲ ↲ ┆b0┆B. Oversigt over ANSI-X3.64, VT-100 og ACP-ANSI↲ ↲ I den følgende tabel gives en kort oversigt over hvilke ↓ styre-tegn og sekvenser, der er defineret i ANSI X3.64 (se ↓ ref 6), samt hvilke der findes i VT100 terminalen fra DEC ↓ og i ACP750 som ANSI terminal.↲ ╱04002d4e0a00050000000002013b31400000000000000000000000000000000000000000000000000c11161e232d37414b555f69737d87ff04╱ ╱04002d4e0a00050000000002013b3140000000000000000000000000000000000000000000000000050a0f19232d373c555f6973ffffffff04╱ ↓ ↲ ┆a1┆Navn ANSI VT100 ACP750╞ Beskrivelse↲ ↲ ALN╞ ╞ +╞ ╞ Screen Alignment Display↲ APC╞ +╞ ╞ ╞ Application Program Command↲ BEL╞ ╞ +╞ +╞ Bell↲ BS╞ ╞ +╞ +╞ Backspace↲ CAN╞ ╞ +╞ +╞ Cancel↲ CBT╞ +╞ ╞ +╞ Cursor Backward Tabulation↲ CCH╞ +╞ ╞ ╞ Cancel Character↲ CHA╞ +╞ ╞ ╞ Cursor Horizontal Absolute↲ CHT╞ +╞ ╞ +╞ Cursor Horizontal Tabulation↲ CNL╞ +╞ ╞ ╞ Cursor Next Line↲ CPL╞ +╞ ╞ ╞ Cursor Preceding Line↲ CPR╞ +╞ +╞ +╞ Cursor Position Report↲ CR╞ ╞ +╞ +╞ Carriage Return↲ CRM╞ +╞ res╞ cnf╞ Control Representation Mode↲ CSI╞ +╞ +╞ +╞ Control Sequence Introducer↲ CTC╞ +╞ ╞ ╞ Cursor Tabulation Control↲ CUB╞ +╞ +╞ +╞ Cursor Backward↲ CUD╞ +╞ +╞ +╞ Cursor Down↲ CUF╞ +╞ +╞ +╞ Cursor Forward↲ CUP╞ +╞ +╞ +╞ Cursor Position↲ CUU╞ +╞ +╞ +╞ Cursor Up↲ CVT╞ +╞ ╞ ╞ Cursor Vertical Tabulation↲ DA╞ +╞ +╞ +╞ Device Attributes↲ DAQ╞ +╞ ╞ ╞ Define Area Qualification↲ DC1╞ ╞ +╞ +╞ Xon↲ DC3╞ ╞ +╞ +╞ Xoff↲ DCH╞ +╞ ╞ +╞ Delete Character↲ DCS╞ +╞ ╞ +╞ Device Control String↲ DHL╞ ╞ +╞ ╞ Double Height Line↲ DL╞ +╞ ╞ +╞ Delete Line↲ DMI╞ +╞ ╞ +╞ Disable Manual Input↲ DSR╞ +╞ +╞ +╞ Device Status Report↲ DWL╞ ╞ +╞ ╞ Double Width Line↲ EA╞ +╞ ╞ ╞ Erase in Area↲ EBM╞ +╞ res╞ res╞ Editing Boundary Mode↲ ECH╞ +╞ ╞ +╞ Erase Character↲ ED╞ +╞ +╞ +╞ Erase in Display↲ EF╞ +╞ ╞ ╞ Erase in Field↲ EL╞ +╞ +╞ +╞ Erase in Line↲ ENQ╞ ╞ +╞ +╞ Enquire↲ ════════════════════════════════════════════════════════════════════════ ↓ Navn ANSI VT100 ACP750╞ Beskrivelse↲ ↲ EMI╞ +╞ ╞ +╞ Enable Manual Input↲ EPA╞ +╞ ╞ ╞ End of Protected Area↲ ERM╞ +╞ set╞ ╞ Erasure Mode↲ ESA╞ +╞ ╞ ╞ End of Selected Area↲ ESC╞ ╞ +╞ +╞ Escape↲ FEAM╞ +╞ res╞ res╞ Format Effector Action Mode↲ FETM╞ +╞ res╞ res╞ Format Effector Transfer Mode↲ FF╞ ╞ ╞ +╞ Form Feed↲ FNT╞ +╞ ╞ ╞ Font Selection↲ GATM╞ +╞ ╞ ╞ Guarded Area Transfer Mode↲ GSM╞ +╞ ╞ ╞ Graphic Size Modification↲ GSS╞ +╞ ╞ ╞ Graphic Size Selection↲ HEM╞ +╞ ╞ res╞ Horizontal Editing Mode↲ HPA╞ +╞ ╞ ╞ Horizontal Position Absolute↲ HPR╞ +╞ ╞ +╞ Horizontal Position Relative↲ HT╞ ╞ +╞ +╞ Horizontal Tabulation↲ HTJ╞ +╞ ╞ ╞ Horizontal Tab with Justify↲ HTS╞ +╞ +╞ +╞ Horizontal Tabulation Set↲ HVP╞ +╞ +╞ +╞ Horiz. and Vertical Position↲ ICH╞ +╞ ╞ +╞ Insert Character↲ ID╞ ╞ +╞ +╞ Identify terminal↲ IL╞ +╞ ╞ +╞ Insert Line↲ IND╞ +╞ +╞ +╞ Index↲ INT╞ +╞ ╞ ╞ Interrupt↲ IRM╞ +╞ res╞ res╞ Insertion-Replacement Mode↲ JFY╞ +╞ ╞ ╞ Justify↲ KAM╞ +╞ res╞ +╞ Keyboard Action Mode↲ KPAM╞ ╞ +╞ ╞ Keypad Application Mode↲ KPNM╞ ╞ +╞ ╞ Keypad Numeric Mode↲ LF╞ ╞ +╞ +╞ Line Feed↲ LL╞ ╞ +╞ ╞ Load Leds↲ LNM╞ +╞ +╞ +╞ Line feed-New line Mode↲ MATM╞ +╞ ╞ ╞ Multiple Area Transfer Mode↲ MC╞ +╞ ╞ +╞ Media Copy↲ MW╞ +╞ ╞ ╞ Message Waiting↲ NEL╞ +╞ +╞ +╞ Next Line↲ NP╞ +╞ ╞ ╞ Next Page↲ OSC╞ +╞ ╞ ╞ Operating System Command↲ PLD╞ +╞ ╞ ╞ Partial Line Down↲ PLU╞ +╞ ╞ ╞ Partial Line Up↲ PM╞ +╞ ╞ ╞ Privacy Message↲ PP╞ +╞ ╞ ╞ Preceding Page↲ PU1╞ +╞ ╞ ╞ Private Use 1↲ PU2╞ +╞ ╞ ╞ Private Use 2↲ PUM╞ +╞ ╞ ╞ Position Unit Mode↲ ════════════════════════════════════════════════════════════════════════ ↓ Navn ANSI VT100 ACP750╞ Beskrivelse↲ ↲ QUAD╞ +╞ ╞ ╞ Quad↲ RC╞ ╞ +╞ +╞ Restore Cursor↲ REP╞ +╞ ╞ ╞ Repeat↲ RI╞ +╞ +╞ +╞ Reverse Index↲ RIS╞ +╞ +╞ +╞ Reset to Initial State↲ RM╞ +╞ +╞ +╞ Reset Mode↲ RPTP╞ ╞ +╞ ╞ Report Terminal Parameters↲ RQTP╞ ╞ +╞ ╞ Request Terminal Parameters↲ SATM╞ +╞ ╞ ╞ Area Transfer Mode↲ SC╞ ╞ +╞ +╞ Save Cursor↲ SCS╞ ╞ +╞ +╞ Select Character Set↲ SD╞ +╞ ╞ ╞ Scroll Down↲ SEM╞ +╞ ╞ ╞ Select Editing Extent Mode↲ SGR╞ +╞ +╞ +╞ Select Graphic Rendition↲ SI╞ ╞ +╞ ╞ Shift In (char set)↲ SL╞ +╞ ╞ ╞ Scroll Left↲ SM╞ +╞ +╞ +╞ Set Mode↲ SO╞ ╞ +╞ ╞ Shift Out (char set)↲ SPA╞ +╞ ╞ ╞ Start of Protected Area↲ SPI╞ +╞ ╞ ╞ Spacing Increment↲ SR╞ +╞ ╞ ╞ Scroll Right↲ SRM╞ +╞ ╞ ╞ Send-Receive Mode↲ SRTM╞ +╞ res╞ res╞ Status Report Transfer Mode↲ SS2╞ +╞ ╞ ╞ Single Shift 2↲ SS3╞ +╞ ╞ ╞ Single Shift 3↲ SSA╞ +╞ ╞ ╞ Start of Selected Area↲ ST╞ +╞ ╞ +╞ String Terminator↲ STBM╞ ╞ +╞ +╞ Set Top and Bottom Margen↲ STS╞ +╞ ╞ ╞ Set Transmit State↲ SU╞ +╞ ╞ +╞ Scroll Up↲ SWL╞ ╞ +╞ ╞ Single Width Line↲ TBC╞ +╞ +╞ +╞ Tabulation Clear↲ TSM╞ +╞ res╞ res╞ Tabulation Stop Mode↲ TSS╞ +╞ ╞ ╞ Thin Space Specification↲ TST╞ ╞ +╞ ╞ Invoke confidence Test↲ TTM╞ +╞ ╞ ╞ Transfer Termination Mode↲ VEM╞ +╞ ╞ res╞ Vertical Editing Mode↲ VPA╞ +╞ ╞ ╞ Vertical Position Absolute↲ VPR╞ +╞ ╞ ╞ Vertical Position Relative↲ VTS╞ +╞ ╞ ╞ Vertical Tabulation Set↲ ↲ bem:↲ res - denne tilstand er aldrig sat.↲ set - denne tilstand er altid sat.↲ cnf - ┆84┆denne tilstand sættes før start, enten med ACPKONF ↓ ┆19┆┆88┆┄┄eller med KONFIG.↲ ┆14┆┆b1┆┆b0┆┆a1┆ACP750┆05┆C. ASCII tegnsæt↲ ┆14┆┆b2┆┆b0┆┆a1┆C. ASCII tegnsæt┆05┆ACP750↲ ┆14┆┆b3┆↲ ┆15┆┆b3┆↲ ┆15┆┆b3┆┆a1┆_ _↲ ┆15┆┆b1┆┆b0┆A/S Regnecentralen ┆05┆-┆0b┆-↲ ┆15┆┆b2┆┆b0┆-┆0b┆- ┆05┆A/S Regnecentralen↲ ↲ ┆b0┆C. ASCII tegnsæt↲ ↲ ↲ Den følgende oversigt viser ASCII tegnsættet i den danske ↓ udgave samt værdierne for hvert enkelt tegn i decimal og ↓ hexadecimal notation.↲ ↲ ╱04002d4e0a00050000000002013b314000000000000000000000000000000000000000000000000003060b12151a212429303338414b55ff04╱ ╱04002d4e0a00050000000002013b31400000000000000000000000000000000000000000000000000c11161e232d37414b555f69737d87ff04╱ ↓ tegn dec hex tegn dec hex tegn dec hex tegn dec hex↲ ↲ NUL╞ 0╞ 00 blank 32╞ 20╞ @╞ 64╞ 40╞ ╞ 96╞ 60↲ SOH╞ 1╞ 01╞ !╞ 33╞ 21╞ A╞ 65╞ 41╞ a╞ 97╞ 61↲ STX╞ 2╞ 02╞ "╞ 34╞ 22╞ B╞ 66╞ 42╞ b╞ 98╞ 62↲ ETX╞ 3╞ 03╞ #╞ 35╞ 23╞ C╞ 67╞ 43╞ c╞ 99╞ 63↲ EOT╞ 4╞ 04╞ $╞ 36╞ 24╞ D╞ 68╞ 44╞ d╞ 100╞ 64↲ ENQ╞ 5╞ 05╞ %╞ 37╞ 25╞ E╞ 69╞ 45╞ e╞ 101╞ 65↲ ACK╞ 6╞ 06╞ &╞ 38╞ 26╞ F╞ 70╞ 46╞ f╞ 102╞ 66↲ BEL╞ 7╞ 07╞ '╞ 39╞ 27╞ G╞ 71╞ 47╞ g╞ 103╞ 67↲ BS╞ 8╞ 08╞ (╞ 40╞ 28╞ H╞ 72╞ 48╞ h╞ 104╞ 68↲ HT╞ 9╞ 09╞ )╞ 41╞ 29╞ I╞ 73╞ 49╞ i╞ 105╞ 69↲ LF╞ 10╞ 0a╞ *╞ 42╞ 2a╞ J╞ 74╞ 4a╞ j╞ 106╞ 6a↲ VT╞ 11╞ 0b╞ +╞ 43╞ 2b╞ K╞ 75╞ 4b╞ k╞ 107╞ 6b↲ FF╞ 12╞ 0c╞ ,╞ 44╞ 2c╞ L╞ 76╞ 4c╞ l╞ 108╞ 6c↲ CR╞ 13╞ 0d╞ -╞ 45╞ 2d╞ M╞ 77╞ 4d╞ m╞ 109╞ 6d↲ SO╞ 14╞ 0e╞ .╞ 46╞ 2e╞ N╞ 78╞ 4e╞ n╞ 110╞ 6e↲ SI╞ 15╞ 0f╞ /╞ 47╞ 2f╞ O╞ 79╞ 4f╞ o╞ 111╞ 6f↲ DLE╞ 16╞ 10╞ 0╞ 48╞ 30╞ P╞ 80╞ 50╞ p╞ 112╞ 70↲ DC1╞ 17╞ 11╞ 1╞ 49╞ 31╞ Q╞ 81╞ 51╞ q╞ 113╞ 71↲ DC2 ╞ 18╞ 12╞ 2╞ 50╞ 32╞ R╞ 82╞ 52╞ r╞ 114╞ 72↲ DC3╞ 19╞ 13╞ 3╞ 51╞ 33╞ S╞ 83╞ 53╞ s╞ 115╞ 73↲ DC4 ╞ 20╞ 14╞ 4 ╞ 52╞ 34╞ T╞ 84╞ 54╞ t╞ 116╞ 74↲ NAK╞ 21╞ 15╞ 5╞ 53╞ 35╞ U╞ 85╞ 55╞ u╞ 117╞ 75↲ SYN╞ 22╞ 16╞ 6╞ 54╞ 36╞ V╞ 86╞ 56╞ v╞ 118╞ 76↲ ETB╞ 23╞ 17╞ 7 ╞ 55╞ 37╞ W╞ 87╞ 57╞ w╞ 119╞ 77↲ CAN╞ 24╞ 18╞ 8╞ 56╞ 38╞ X╞ 88╞ 58╞ x╞ 120╞ 78↲ EM╞ 25╞ 19╞ 9╞ 57╞ 39╞ Y╞ 89╞ 59╞ y╞ 121╞ 79↲ SUB╞ 26╞ 1a╞ :╞ 58╞ 3a╞ Z╞ 90╞ 5a╞ z╞ 122╞ 7a↲ ESC╞ 27╞ 1b╞ ;╞ 59╞ 3b╞ Æ╞ 91╞ 5b╞ æ╞ 123╞ 7b↲ FS╞ 28╞ 1c╞ <╞ 60╞ 3c╞ Ø╞ 92╞ 5c╞ ø╞ 124╞ 7c↲ GS╞ 29╞ 1d╞ =╞ 61╞ 3d╞ Å╞ 93╞ 5d╞ å╞ 125╞ 7d↲ RS╞ 30╞ 1e╞ >╞ 62╞ 3e╞ ^╞ 94╞ 5e╞ ü╞ 126╞ 7e↲ US╞ 31╞ 1f╞ ?╞ 63╞ 3f╞ _╞ 95╞ 5f DEL╞ 127╞ 7f↲ ↲ ┆14┆┆b1┆┆b0┆┆a1┆ACP750┆05┆D. Lokale kommandoer i funktionstasterne↲ ┆14┆┆b2┆┆b0┆┆a1┆D. Lokale kommandoer i funktionstasterne┆05┆ACP750↲ ┆14┆┆b3┆↲ ┆15┆┆b3┆↲ ┆15┆┆b3┆┆a1┆_ _↲ ┆15┆┆b1┆┆b0┆A/S Regnecentralen ┆05┆-┆0b┆-↲ ┆15┆┆b2┆┆b0┆-┆0b┆- ┆05┆A/S Regnecentralen↲ ↲ ┆b0┆D. Lokale kommandoer i funktionstaster↲ ↲ ↲ Når den lokale kommandotast A1 nedtrykkes, dannes tegn-↓ sekvensen <128> 1 (hex: 80 31). Ved at lægge disse værdier ↓ i en af funktionstasterne (F1 - F12) efterfulgt af ↓ valgbogstaverne for de ønskede kommandoer, kan man få ↓ udført en sekvens af kommandoer.↲ ↲ Eksempel: ┆84┆F1 skal anvendes i forbindelse med RcTekst til at ↓ ┆19┆┆8a┆┄┄tage en skærmkopi og indflette denne i en tekst.↲ ↲ Funktion: Værdi/tast:↲ Lokal kommando-tilstand╞ <128> 1↲ Vælg kopi-enhed╞ ╞ K↲ Vælg file╞ ╞ ╞ F↲ Filnavn╞ ╞ ╞ KOPI.BLK<retur>↲ Overskriv: Ja╞ ╞ J↲ Tag kopi╞ ╞ ╞ T↲ Vælg kopi-enhed╞ ╞ K↲ Luk fil╞ ╞ ╞ L↲ Retur til kommando-tilstand╞ <retur>↲ Return til terminal-tilstand╞ <retur>↲ ↲ <retur> angiver, at der trykkes på RETUR-tasten. Ved ↓ indtastning af sekvensen skrives følgende:↲ ↲ F1 =┆b0┆ ^80 1 K F KOPI.BLK <retur> J T K L <retur> <retur>↲ ↲ Mellemrum er kun indsat af hensyn til overskueligheden; de ↓ skal ikke tastes med.↲ ↲ ↲ ┆1a┆┆1a┆↲ ↓ ┆1a┆↓ ↲ ↲ ↓ ┆1a┆┆1a┆┆1a┆┆1a┆┆1a┆┆1a┆!┆00┆┆10┆┆e9┆!t┆a5┆┆c3┆┆10┆┆a5┆┆13┆┆1a┆┆ed┆┆a1┆┆c0┆┆ea┆┆da┆┆a2┆┆c9┆>┆05┆2┆11┆┆b0┆┆af┆21┆a5┆┆0e┆┆f2┆>┆05┆*┆0f┆┆b0┆┆ed┆Ææ┆a4┆┆cd┆┆9d┆┆a4┆┆cd┆!┆a4┆┆cd┆3┆a4┆8┆e6┆ed KONFIG.