⟦3bdbba6a2⟧ TextFile

    Length: 15616 (0x3d00)
    Types: TextFile
    Names: »D1«

Derivation

└─⟦e61e7d03c⟧ Bits:30005867/disk01.imd Dokumenter (RCSL m.m.)
    └─⟦this⟧ »D1« 

TextFile

                                                i 
           
          T_A_B_L_E_ _O_F_ _C_O_N_T_E_N_T_S_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _P_A_G_E_ 
           
          1.  CONTROL PANEL .........................................   1 
           
          2.  OPERATING PROCEDURES ..................................   5 
              2.1  Loading the Tape .................................   5 
                   2.1.1  Loading the Reel ..........................   5 
                   2.1.2  Start Procedure ...........................   6 
              2.2  Unloading the Tape ...............................   7 
                   2.2.1  Stop Procedure ............................   7 
                   2.2.2  Unloading the Reel ........................   8 
           
          3.  SUPPLEMENTARY NOTES ...................................   9 
              3.1  Maintenance ......................................   9 
           \f

                                               ii 
           \f

         1_._ _ _ _ _ _ _ _ _C_O_N_T_R_O_L_ _P_A_N_E_L_ 1.
           
           
           
           
           
           
           
           
           
           
           
           
           
           
           
           
          Figure 1: Control Panel. 
           
          1) POWER                              - when pressed to light,
             push-button/indicator                power is applied to the
                                                  tape unit.  
                                                   
          2) LOAD                               - when pressed to light, a
             push-button/indicator                load sequence is ini-
                                                  tiated. 
                                                   
                                                  Pressing and releasing
                                                  the LOAD push-button for
                                                  the first time after
                                                  mounting a reel of tape,
                                                  causes the tape to be
                                                  tensioned. 
                                                   
                                                  Pressing and releasing it
                                                  a second time, causes the\f

                                                           tape to advance to the
                                                  BOT mark and stop. (BOT =
                                                  b_eginning o_f t_ape; EOT =
                                                  e_nd o_f tape). 
                                                   
          3) ON LINE                            - when pressed to light,
             push-button/indicator                the tape unit is in the
                                                  on-line mode. This
                                                  control can only be used
                                                  after having performed a
                                                  load, or rewind,
                                                  sequence. 
                                                   
                                                  Pressing and releasing it
                                                  a second time will cause
                                                  the unit to go off-line.
                                                  The off-line mode can
                                                  also be caused by a
                                                  system command, or by
                                                  lack of tape tension. 
           
          4) REWIND                             - when pressed to light,
             push-button/ indicator               the tape will rewind at
                                                  maximum speed. This con-
                                                  trol can only be used in
                                                  the off-line mode. 
                                                   
                                                  On reaching the BOT mark,
                                                  the rewind drive ceases
                                                  and the load sequence is
                                                  automatically entered.
                                                  The REWIND indicator
                                                  remains lit also during
                                                  the subsequent load
                                                  sequence. 
                                                   
          5) WRT EN (W_r_it_e E_n_able)              - this indicator is illumi-
             indicator                            nated, when mounting a
                                                  reel of tape with a write
                                                  enable ring. \f

                                                           If no write enble ring is
                                                  mounted, the tape unit
                                                  can only read from the
                                                  tape. 
                                                   
          6) HI DEN (H_i_gh D_e_n_sity)              - when pressed to ligth,
             push-button/indicator                the high density record-
                                                        ing method is selected.
                                                  The selecting of density
                                                  by this control depends
                                                  on the optional features
                                                  installed: 
                                                   
                          RC3610S:                The control is not ope-
                                                  rable; indicator always
                                                  lit (PE/1600 bpi).  
                                                   
                          RC3615S:                Indicator lit, selects
                                                  high density (PE/1600
                                                  bpi), if feature is in-
                                                  stalled. 
                                                   
                                                  Indicator not lit, se-
                                                  lects low density
                                                  (NRZI/800 bpi), if
                                                  feature is installed. 
                                                   
                          RC3620S:                The control is not ope-
                                                  rable; indicator never
                                                  lit (NRZI/800 bpi). 
                                                   
          7) FORWARD                            - when pressed to ligth,
             push-button/indicator                the tape will be moved
                                                  forward at normal opera-
                                                  ting speed. This control
                                                  can only be used in the
                                                  off-line mode. 
                                                   \f

                                                  Pressed and releasing it
                                                  a second time will cause
                                                  the tape to stop. 
                                                   
          8) REVERSE                            - moves the tape in the
             push-button/indicator                reverse direction, other-
                                                  wise functioning as the
                                                  FORWARD control. 
                                                   \f

         2_._ _ _ _ _ _ _ _ _O_P_E_R_A_T_I_N_G_ _P_R_O_C_E_D_U_R_E_S_ 2.
           
          The operating points are shown in fig. 2. The tape unit is de-
          signed for a maximum reel diameter of 10.5 inches (corresponding
          to 2400 feet of tape). 
           
          The supply reel, i.e. the reel of tape to be read or written,
          always is the lower reel. Note that the presence of a write
          enable ring is required to close the interlocks which allow
          writing (otherwise reading is possible only). 
           
           
2_._1_ _ _ _ _ _ _ _L_o_a_d_i_n_g_ _t_h_e_ _T_a_p_e_ 2.1
           
2_._1_._1_ _ _ _ _ _L_o_a_d_i_n_g_ _t_h_e_ _R_e_e_l_ 2.1.1
           
          The tape is loaded as the supply reel (lower reel). The tape must
          unwind from the supply reel when the reel is turned in a
          clockwise direction. To load the tape reel, position the reel
          over the quick-release hub and press the center plunger. This
          allows the reel to slip over the rubber ring on the hub. Press
          the reel evenly and firmly against the back flange of the hub,
          still with the center plunger pressed inwards. Release the center
          plunger. The reel is now properly aligned in the tape path and
          ready for tape threading. Then rotate the supply reel to give
          about 1.5 meters of free tape. 
           
                   Thread the tape along the path shown in fig. 2. It will be neces-
          sary to rotate the supply reel and hold the flux gate unit away
          from the head during tape threading. 
           
          Wrap the tape leader onto the take-up reel so that the tape will
          be wound onto the reel when it is rotated clockwise. Wind several
          turns onto the take-up reel, then turn the supply reel counter-
          clockwise until slack tape has been taken up. 
           \f

           
           
           
           
           
           
           
           
           
           
           
           
           
           
           
           
           
           
           
           
          Figure 2: Operating points; tape threading path. 
           
           
           
2_._1_._2_ _ _ _ _ _S_t_a_r_t_ _P_r_o_c_e_d_u_r_e_ 2.1.2
           
          After the tape has been manually tensioned and checked for
          correct seating in the guides, bring the tape to the load point
          as follows. 
           
                   1.  Switch on power by pressing the POWER push-button. If
              desirable, power can automatically be switched on/off as the
              system is switched on/off, when after the initial power-on
              sequence the POWER push-button is left untuched. 
               
          2.  Press and release the LOAD push-button. This applies power to
              the capstan and reel motors and brings the tape to the
              correct operating tension. The tape storage arms are now in
              the operating position. 
               \f

              CAUTION: Check that the tape is positioned correctly on all
                       guides or tape damage may result. 
                        
          3.  Press and release the LOAD push-button a second time. This
              causes the tape to move forward. When the reflective BOT mark
              reaches BOT/EOT tab sensor, the tape is at load point and
              stops. Check the tape tracking in the guides again and close
              the dust cover. 
               
              CAUTION: The dust cover should remain closed at all times
                       when a tape is on the take-up reel. Data reliability
                       may be impaired by dust and other particles in the
                       air if the cover is left open. 
               
          4.  Select the correct recording density, using the HI DEN
              push-button (if applicable). 
               
          5.  Depress the ON LINE push-button. When the indicator lights,
              the tape unit is ready to receive system commands. 
               
               
2_._2_ _ _ _ _ _ _ _U_n_l_o_a_d_i_n_g_ _t_h_e_ _T_a_p_e_ 2.2
           
2_._2_._1_ _ _ _ _ _S_t_o_p_ _P_r_o_c_e_d_u_r_e_ 2.2.1
           
          1.  Ensure that the tape unit is in the off-line mode, i.e. the
              ON LINE indicator is not lit. If necessary, press and release
              the ON LINE push-button in order to establish the off-line
              mode. 
           
              CAUTION: Only switch the tape unit off-line, while the tape
                       is at rest. 
           
          2.  Press and release the REWIND push-button. When the tape has
              rewound to the BOT mark, it comes to a controlled stop. The
                       tape overshoots and the transport enters the load sequence to
              bring the tape to rest at the BOT mark. 
               \f

          3.  Press and release the REWIND control a second time. This
              initiates a further rewind action which continues until
              tension is lost. 
           
           
2_._2_._2_ _ _ _ _ _U_n_l_o_a_d_i_n_g_ _t_h_e_ _R_e_e_l_ 2.2.2
           
          After having performed the stop procedure, the reel is unloaded
          by, 
           
              - opening dust cover, 
              - manually rewinding end of tape onto the supply reel, 
              - pressing the hub center plunger and remowing the reel. 
               
          Always keep the dust cover closed, when not operating the tape
          unit. 
           
          Switch off POWER (aslo cf. 2.1.2 step 1). 
           \f

         3_._ _ _ _ _ _ _ _ _S_U_P_P_L_E_M_E_N_T_A_R_Y_ _N_O_T_E_S_ 3.
           
3_._1_ _ _ _ _ _ _ _M_a_i_n_t_e_n_a_n_c_e_ 3.1
           
          E_a_c_h_ _d_a_y_ _(_e_a_c_h_ _8_ _h_o_u_r_s_ _o_f_ _o_p_e_r_a_t_i_o_n_)_ 
           
          Clean the read-write-heads, the guides, and the capstan using a
          swab stick, or lint free cloth, damped with isopropyl alcohol. 
           
          Do not use too much fluid; the excessive fluid may easily
          penetrate the bearings and damage these. 
           
          Observe: Other detergents such as methylated spirit can damage
                   the read-write-heads and the capstan. 
                    \f

 
 \f

«eof»