┆b0┆┆a1┆1. EUIPMENT↲
↲
┆84┆A DUAL-CIRCUIT installation includes two local network ↓
┆19┆┆89┆┄┄CIRCUIT I and CIRCUIT II.↲
↲
┆84┆CIRCUIT I consist of maximum 7 slaveterminals and one↓
┆19┆┆89┆┄┄masterterminal, all terminals from the RC850 serie. If ↓
┆19┆┆89┆┄┄the master is an RC890 there can be a total of 32 ↓
┆19┆┆89┆┄┄connections.↲
↲
┆84┆CIRCUIT II shall have an RC3900 as master, and can have ↓
┆19┆┆89┆┄┄up to 32 connections for terminals from the RC850 serie.↲
↲
┆84┆The DUAL-CIRCUIT line is established as a fixed twisted ↓
┆19┆┆89┆┄┄pair wire installation, which is lead through a frame ↓
┆19┆┆89┆┄┄for each receptacle.↲
↲
┆84┆The master is connected to modem equipment if any, and ↓
┆19┆┆89┆┄┄to the DUAL CIRCUIT line. The slaves are connected to ↓
┆19┆┆89┆┄┄the DUAL CIRCUIT line.↲
↲
┆84┆The cabling and further specifications appears from the ↓
┆19┆┆89┆┄┄scematics and the figures.↲
↲
┆84┆Further the terminals can be equipped with various ↓
┆19┆┆89┆┄┄external equipment.↲
════════════════════════════════════════════════════════════════════════
↓
┆b0┆┆a1┆2. DELIVERING↲
↲
┆b0┆Cable for Length Delivering Remarks↲
CIRCUIT max.1500m By order ┆84┆the customer ↓
┆19┆┆af┆┄┄establishes the ↓
┆19┆┆af┆┄┄DUAL CIRCUIT line ↓
┆19┆┆af┆┄┄with the recept- ↓
┆19┆┆af┆┄┄acle. Theese can ↓
┆19┆┆af┆┄┄be ordered at RC, ↓
┆19┆┆af┆┄┄who also can do ↓
┆19┆┆af┆┄┄the installation↲
┆a1┆ ↲
Telephone 1,5 m with modem ↲
┆a1┆ ↲
Terminal↲
TF672 5 m with only for CIRCUIT I↲
TF673 5 m equipment ┆84┆both CIRCUIT I and ↓
┆19┆┆ae┆┄┄II ↲
┆a1┆ ↲
Modem 5 m " ┆84┆other length 12 and ↓
┆19┆┆ae┆┄┄25 m. if ordered.↲
┆a1┆ ↲
Keyboard 1,5 m " ↲
┆a1┆ ↲
↲
↲
↲
↲
↲
↲
↲
↲
↲
↲
↲
↲
↲
↲
↲
↲
Figure 1: RC DUAL-CIRCUIT Installation.↲
↲
Type of cable : ┆84┆2x2x0.6mm. twisted pair (example NEK ↓
┆19┆┆9b┆┄┄PT/CN-1)↲
Length of cable : maximum 1500 meters↲
Wall receptacle : TF669↲
Terminal cable : TF673↲
↲
════════════════════════════════════════════════════════════════════════
↓
┆84┆The wall receptacle WRF501 is meant to be mounted in a ↓
┆19┆┆89┆┄┄frame from LK-NES plantangent serie.↲
↲
┆84┆Usually the installation of RC DUAL-CIRCUIT is made by ↓
┆19┆┆89┆┄┄the customer, including the empty frame for the WRF501. ↓
┆19┆┆89┆┄┄Installation can be ordered at RC.↲
↲
Please note: ┆84┆When the WRF501 is mounted the two ↓
┆19┆┆96┆┄┄resistors has to be removed, ┆a1┆except for the ↓
┆19┆┆96┆┄┆84┆two receptacles at the endpositions ↓
┆19┆┆96┆┄┆84┆(impedancematching). See fig. 2.↲
↲
↲
↲
↲
↲
↲
↲
↲
↲
↲
↲
Figure 2: Wiring of WRF501.↲
↲
┆84┆The wiring has to be done so the colour coding in the ↓
┆19┆┆89┆┄┄cable is reestablished.↲
↲
↲
↲
↲
↲
↲
↲
↲
↲
↲
↲
↲
↲
Figure 3: TF669 seen from behind.↲
↲
┆84┆Further description of CIRCUIT II and the corresponding ↓
┆19┆┆89┆┄┄protocol can be found in CIRCUIT II Reference Manual ↓
┆19┆┆89┆┄┄RCSL No ↲
↲
════════════════════════════════════════════════════════════════════════
↓
↲
════════════════════════════════════════════════════════════════════════
↓
↓