R E L E A S E D E S C R I P T I O N
*******************************************************
Module id number: CSS/107
--------------------------
Module name: AMOS/DAMOS Utilityhelp
-----------------------------------
Actual release: 04.02 Release date: 851015
----------------------- --------------------
04.01 ( NOT SCL) 850625
Previous release: 03.02 Release date: 840507
----------------------- --------------------
New facilities:
---------------
>> Release 2 <<
The name of the program is read from the first line of the parameter file
and exported via the record
PROG_ID :
RECORD
P_FSN: file_system_name;
P_VOL: volume_name;
P_NAMELIST: namelisttype;
P_NAMENO: integer;
P_FROMADAM : integer;
END;
Interface to the database containing completion codes via
PROCEDURE LOOKUP_ERROR_TEXT
(R3; "C K @ ERROR_TEXT SAVE AREA (132 chars = 66 words)
R7; "C K COMPLETION CODE
R6): "- D LINK
error_done;
The database must consist of two files situated in the same directory as the
program :
DAMOS AMOS
---- ----
DC.X CC.X : two word byte pointers to
DC.T CC.T : error texts
Changes:
--------
>> Release 3.2 <<
'Open File' prints the name of the file or directory that gives
problem.
(PR 1017)
The current file name is t«soh»aken from current directory in parameter
file in DAMOS version (AMOS version has done this for a long time).
This will solve the problem of using additional filesystem(s).
(PR 1085)
>> Release 4.1 <<
( MXAMOS only : )
When compiled with the constant 'NO_TOS' true, the resulting link
module will operate without TOS ( and therefore will it neither
support nor need disk access ).
Errors corrected:
-----------------
>> Release 3.1 <<
( DAMOS only : )
This module opens CIN,COUT and OIN. The number of (file) connections
is optimized by opening CIN and only open COUT and OIN if their names
differ from the name of CIN (If not then just copy the file handle
from CINFILETYPE.F to COUTFILETYPE.F or OINFILETYPE.F).
The rationale is
a) it saves resources of type FDCBS
b) There is a short delay (at least one second) in TMS for each
switch between two connections i.e. interactive programs
are speeded up when the input and output stream share connection.
Version 2.2 failed on two accounts :
1) The volume name was not taken into consideration.
2) Two files need only have the same number of names to
be considered identical.
>> Release 4.2 <<
Minor errors in module generation corrected
Reported errors, not corrected:
-------------------------------
CPECRs implemented in current release: none
--------------------------------------
Comments:
---------
«a5»