APPENDIX B1…01…***************…01……01…TECHNICAL REQUIREMENTS AND SPECIFICATIONS…01…FOR V24/V28 (L/L)-ADAPTORS
T̲E̲C̲H̲N̲I̲C̲A̲L̲ ̲R̲E̲Q̲U̲I̲R̲E̲M̲E̲N̲T̲S̲ ̲A̲N̲D̲ ̲S̲P̲E̲C̲I̲F̲I̲C̲A̲T̲I̲O̲N̲S̲
The V24/V28 (L/L)-adaptors (in the following V28(L)-adaptors)
to be supplied under this contract shall meet the specifications
and requirements specified in this appendix.
1̲ ̲ ̲G̲E̲N̲E̲R̲A̲L̲ ̲S̲P̲E̲C̲I̲F̲I̲C̲A̲T̲I̲O̲N̲
The V28(L) adaptor converts standard CCITT V24/V28 signal levels
within a data channel to low level signals. The adaptors shall
be implemented on a PC-Board (CAMAC, 5U) to be placed in a 19
inch TDX-crate. The crate will be mounted within a EMI-rack-assembly,
which privides high shielding effectiveness against electromagnetic
emanation to the environments.
Fig. 1-1 to 1-8 defines racks, crate and module. Two versions
of the V24(L)-adaptor shall be implemented. The functional requirements
to the two versions are defined in section 3 of this appendix.
The circuit design shall be based on Interim Report No. 3 dated
May 1, 1981, prepared by ARC for CR.
A sample of the 5u-Camac modules (fig. 1-4) to be used for the
two versions will be delivered to ARC by CR A/S.
In case of inconsistency between fig. 1-4 and the model, the
latter shall take precedence.
The front panels for the two versions are designed by CR.
The mechanical items for the modules (front panel, runners,
etc.) are supplied by CR. ARC integrates the modules completely.
The cables leaving the V28(L)-adaptor modules will be led through
a Filter Box (see appendix B2 of this contract).
The signals leaving the Filter Box shall comply with the following
requirements:
a) All electrical interconnections for data between the
equipment will use low level keying systems, i.e. 6-0-6
volts at currents less than one milli-ampere. All the
remaining control lines should conform to CCITT Recommendation
V28.
b) MIL-STD-188C
The design shall allow the adaptors to drive cable
lengths up to 900 ft.
SINGLE EMI-RACK, DIMENSIONS…01…Fig. 1-1
CAMPS MAIN SITE…01…3-BAY EMI-RACK…01…Fig.1-2
19" TDX-CRATE…01…Fig.1-3
5U-CAMAC-MODULE…01…SIDE VIEW…01…Fig. 1-4
PLACEMENT OF TDX-CRATES AND FILTER BOX…01…IN 3-BAY EMI-RACK…01…Fig. 1-5
V28(L)-ADAPTOR, FUNCTIONAL PLACEMENT…01…PRINCIPLE DIAGRAM…01…Fig. 1-6
TDX/CRATE WITH ADAPTORS MOUNTED…01…(FRONT VIEW)…01…Fig. 1-7 (Sheet 1 of 3)
TDX/CRATE WITH ADAPTORS MOUNTED…01…(Front view)…01…Fig. 1-7 (Sheet 2 of 3)
TDX/CRATE WITH ADAPTORS MOUNTED…01…(front view)…01…Fig. 1-7 (Sheet 3 of 3)
CHANNEL ALLOCATION ON MOTHERBOARD…01…IN TDX/CRATE…01…Principle Diagram…01…Fig. 1-8
2̲ ̲ ̲E̲N̲V̲I̲R̲O̲N̲M̲E̲N̲T̲
V28(L)-adaptors shall operate within the specified
limits under environmental conditions as specified
below:
2.1 Ambient temperature range: 0 to 50 deg. C.
Change: max. 10 deg. C per hour.
Change: Max. 6% RH per hour.
The modules will be cooled by vertical airflow, see
figure 1.1 to 1.7.
2.2 Humidity: 40 - 90% relative humidity (% RH), non-condensing.
2.3 Altitude: Sea level to 2000 meter.
2.4 D̲U̲S̲T̲,̲ ̲F̲U̲M̲E̲S̲
The equipment shall be able to operate continuously
and with normal scheduled preventive maintenance in
the following air environment:
a) A̲i̲r̲ ̲c̲l̲e̲a̲n̲n̲e̲s̲s̲
Particle Size Max Allowable Number
(̲m̲i̲c̲r̲o̲n̲s̲)̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲(̲P̲a̲r̲t̲i̲c̲l̲e̲s̲/̲c̲u̲b̲i̲c̲m̲e̲t̲e̲r̲)̲
greater than 5 4 x 10…0e…5…0f…
greater than 1.5 4 x 10…0e…6…0f…
greater than 1 4 x 10…0e…7…0f…
b) F̲u̲m̲e̲s̲
Sulphur dioxide max. 14 ppm.
3̲ ̲ ̲P̲H̲Y̲S̲I̲C̲A̲L̲ ̲A̲N̲D̲ ̲F̲U̲N̲C̲T̲I̲O̲N̲A̲L̲ ̲S̲P̲E̲C̲I̲F̲I̲C̲A̲T̲I̲O̲N̲S̲
3.1 V̲E̲R̲S̲I̲O̲N̲S̲
For the CAMPS application 2 versions of the V28(L)-adaptor
are defined:
a) Version 1
b) Version 2
3.1.1 V̲e̲r̲s̲i̲o̲n̲ ̲1̲
The V28(L) adaptor, version 1, shall conform with the
following requirements:
a) Number of V28(L) channels pr. module: 4.
b) CCITT V24 circuits pr. channel:
102: Signal Ground
103: Transmitted data
104: Received data
105: Request to send
107: Data Set Ready
108/2: Data Terminal Ready
c) Waveshaping: The circuits (except 102) are waveshaped
for 1200 bps.
d) It shall pr. channel be possible, by moving one
strap, to select invert/not invert for all circuits
103-108/2 at a time (ref. fig. 3.1.1-1). This allows
the user to select signal polarity according to
MIL-STD-188C or CCITT V28.
On the receiver circuits programming of input impedance
and threshold voltage (V28/Mil-188 c) shall be
provided by straps.
The straps shall not be field replaceable. Version
1 shall be programmed for V28-levels and shall
provide fail-safe operation.
e) Mechanical Dimensions (See fig. 1-4):
Height: 221.5 mm (5U)
Width: 34.2 mm(2M)
Length: 305.0 mm
f) Front Panel:
4 V24 connectors type db 25, male, 1 per channel,
are placed on the front panel for connection of
cables to the Filter Box.
Pin allocation in the connector is shown on figure
3.2-4.
In addition to signal gnd (pin 7) a separate signal
ground pin shall be allocated for each driver current,
as specified in the following scheme:
Driver pin Separate gnd pin
2/3 14
20/6 19
5 16
SIGNAL INVERSION…01…Fig. 3.1.1-1
3.1.2 V̲e̲r̲s̲i̲o̲n̲ ̲2̲
The V28(L)-Adaptor, version 2, shall conform with the
following requirements:
a) Number of V28(L) channels per module: 1.
b) CCITT V24 circuits per channel:
102: Signal Ground
103: Transmitted Data
104: Received Data
105: Request to Send
106: Clear to Send
107: Data Set Ready
108/2: Data Terminal Ready
109: Carrier Detect
113/114 Transmitted Clock
115: Receiver Clock.
c) Waveshaping: The circuitws (except 102) are waveshaped
for 9600 bps.
d) It shall be possible, by moving one strap, to select
invert/non invert for all circuits 103-109 at a
time (ref. 3.1.1-1). Selection of invert/non invert
for 113/114 and 115 should be done by moving one
strap for each. This allows the user to select
signal polarits according to MIL-STD-188C or CCITT
V28.
On receiver circuits programming of input impedance
and threshold volgate (V28/mil-188c) shall be provided
by straps.
The straps shall not be field-replaceable. Version
2 shall be programmed for V28 levels and shall
provide fail-safe operation.
e) Mechanical dimensions:
Height: 221.5 mm (5U)
Width: 17.1 mm (1M)
Length: 305.0 mm
f) Front Panel:
One V24 connector type db25, male, is placed on
the front panel for connection of cables to the
Filter Box.
Pin allocation in the connector is shown on figure
3.2-5.
In addition to signal gnd (pin 7) a separate signal
ground pin shall be allocated for each driver circuit
as specified in the following scheme.
Driver pin Separate gnd pin
2/3 14
20/6 19
4/5 16
24/15 12
17 18
3.2 I̲M̲P̲L̲E̲M̲E̲N̲T̲A̲T̲I̲O̲N̲
The two adaptor versions shall be implemented using
the same basic Printed Circuit Board (PCB). This PCB
shall fit in the CR 5u CAMAC mechanics and have an
edge connector (86 poled (A1-A43, B1-B43) towards the
CTX crate motherboard.
CTX Motherboard signals are shown in fig. 3.2-1 (the
version 1 adaptor) and in fig. 3.2-2 (the version 2
adaptor). (All the pins within the channel areas #1
to #4 are used).
To cope with the different configurations involved
in the version 1 and version 2 adaptors the PCB is
divided in 4 areas (refer to fig. 3.2-3):
a) 3 areas for a reduced configuration.
b) 1 area for an extended configuration.
This area contains as a subset the reduced configuration
area.
In the version 1 adaptor the 4 reduced configuration
areas will each be equipped as outlined in fig. 3.2.-4.
In the version 2 adaptor the extended configuration
area will be equipped as outlined in fig. 3.2-5.
The strap-options indicated shall be designed to allow
for re-programming in the field.
Initial placement of straps for production will be
specified by CR.
VERSION 1…01…CTX MOTHERBOARD SIGNALS…01…Fig. 3.2-1
VERSION 2…01…CTX MOTHERBOARD SIGNALS…01…Fig. 3.2-2
PRINTED CIRCUIT BOARD, CONFIGURATION AREA SPLITS…01…Fig. 3.2-3
REDUCED CONFIGURATION AREA…01…Fig. 3.2-4
EXTENDED CONFIGURATION AREA…01…Fig. 3.2-5 (Sheet 1 of 2)
EXTENDED CONFIGURATION AREA…01…Fig. 3.2-5 (sheet 2 of 2)
3.3 P̲O̲W̲E̲R̲ ̲S̲O̲U̲R̲C̲E̲S̲
The module shall be able to be powered by two alternative
power sources. The source is selected by straps on
the module or an equivalent method.
These starps shall not be field exchangeable. The Version
1 - and Version 2 - modules to be supplied under this
contract shall be powered by AC-power.
a) DC-power (see. fig. 3.2-1 and 3.2-2).
available regulated voltage:
a1) + 5v
a2) + 12v
a3) - 12v
b) AC-power (see fig. 3.2-1 and 3.2-2)
b1) The module is powered by 2 x 9 VAC from a transformer
unit through 3 set of pins of the edge connector.
b1.1) Power input from the transformer unit:
9 VAC + 10%/- 15%
50 HZ + 10%/- 10%
b1.2) Harmonic distortion: Max. 5%
b2) The transformer unit converting to 2 x 9 VAC
nominal is shown on fig. 3.3-1..
The supply voltage is delivered from a centertapped
transformer, and must be rectified and regulated
"on board" to provide the necessary "on board"
DC voltages.
Each winding is capable of delivering 9V at
4,2 A.
It is a requirement that the 2 adaptor versions
are designed so that the above mentioned available
power can support either one of the below mentioned
configurations:
- 2 adaptors version 1
- 8 adaptors version 2
- 1 adaptor version 1 + 4 adaptors version
2.
POWER SUPPLY…01…Fig. 3.3-1