…1f……00……00……00……00…L…0a……00……00…L…0c…L…0d…L…02…6…08…6…09…6…0c…6…0f…6…01…6…06…5…09…5…0e…5…02……86…1 …02… …02… …02…
2988A/rt/ …02…CPS/TCM/005
…02…KJA/830912…02……02…
CAMPS SITE LEVEL MAINTENANCE MANUAL
…02…Issue 1…02… CAMPS
TDX TEST PROCEDURES STEP 4000-5000 (cont'd)
STEP PROCEDURE OBSERVATION/ACTION
̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲
2988A/rt/ …02…CPS/TCM/005
…02…KJA/830912…02……02…
CAMPS SITE LEVEL MAINTENANCE MANUAL
…02…Issue 1…02… CAMPS
4.3.3.4 T̲D̲X̲ ̲T̲e̲s̲t̲ ̲P̲r̲o̲c̲e̲d̲u̲r̲e̲s̲
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
4000 TDX TEST ENTRY
Before start of the TDX test
procedure, verify that
1.The commands typed on the Maint.Ps.VDU
are directed to the PU which
should execute the test.
2.The PU is offline
3.The PU is enabled
4.The PU is in Normal Mode
It is possible to obtain these
conditions e̲i̲t̲h̲e̲r̲
a) by commands issued from the
Maint.Pos. VDU via the Wath Dog
Subsystem
o̲r̲
b) by manual switchs settings
on the MAP module and a reconfiguration
procedure.
a.1) P̲U̲ ̲ ̲ ̲M̲a̲i̲n̲t̲.̲P̲o̲s̲.̲V̲D̲U̲ ̲c̲o̲m̲m̲u̲n̲i̲c̲a̲t̲i̲o̲n̲
̲b̲y̲ ̲t̲h̲e̲ ̲W̲D̲ ̲C̲o̲m̲m̲a̲n̲d̲
PUNno, no is No of the actual
PU (refer to section 5.76 in
(*))
a.2) P̲U̲ ̲O̲F̲L̲I̲N̲E̲ ̲B̲Y̲ ̲T̲H̲E̲ ̲W̲D̲ ̲c̲o̲m̲m̲a̲n̲d̲:̲
OFLI (refer to section 5.7.7
in (*))
a.3) P̲U̲ ̲e̲n̲a̲b̲l̲e̲d̲ ̲b̲y̲ ̲t̲h̲e̲ ̲W̲D̲ ̲c̲o̲m̲m̲a̲n̲d̲:̲
̲E̲N̲P̲U̲
(refer to section 5.7.4
in (*)).
a.4) P̲U̲ ̲ ̲n̲o̲r̲m̲a̲l̲ ̲m̲o̲d̲e̲ ̲t̲h̲e̲ ̲W̲D̲ ̲c̲o̲m̲m̲a̲n̲d̲:̲
̲N̲O̲R̲M̲
(refer to section 5.7.9
in (*))
(*) CAMPS MINTENANCE POSITION
OPERATION MANUAL, Doc.No. CPS/OPM/005
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *…86…1 …02… …02… …02… …02… …02…
b.1) P̲U̲ ̲ ̲M̲a̲i̲n̲t̲.̲ ̲P̲o̲s̲.̲ ̲V̲D̲U̲ ̲c̲o̲m̲m̲u̲n̲i̲c̲a̲t̲i̲o̲n̲
̲b̲y̲ ̲r̲e̲c̲o̲n̲f̲i̲g̲u̲r̲a̲t̲i̲o̲n̲:̲
It is possible to connect
the Maint.Pos.VDU directly
to the PU by a reconfiguration
procedure. The procedure
i described in step 3600
- 3700 in section 4.3.3.3.
b.2) P̲U̲ ̲O̲f̲f̲l̲i̲n̲e̲ ̲b̲y̲ ̲s̲w̲i̲t̲c̲h̲s̲e̲t̲t̲i̲n̲g̲
The PU is taken offline
by pressing the MC button
situated on the front
of the MAP module in the
actual PU (refer to section
4.5).
b.3) P̲U̲ ̲e̲n̲a̲b̲l̲e̲d̲ ̲b̲y̲ ̲s̲w̲i̲c̲h̲s̲e̲t̲t̲i̲n̲g̲.̲
The PU is enabled by switching
the EN/DIS switch on the
front of the MAP module
in the actual PU to the
EN position (refer to
section 4.5)
b.4) P̲U̲ ̲ ̲N̲o̲r̲m̲ ̲M̲o̲d̲e̲ ̲b̲y̲ ̲S̲w̲i̲t̲c̲h̲s̲e̲t̲t̲i̲n̲g̲:̲
The PU is set in normal
mode by switching the
MAN/NRM switch on the
front of the MAP module
to the NRM position (refer
to section 4.5)
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * *
4005 Check the o The
configuration
of
the
PU
should
be
configuration of identical to the onfiguration
shown
the PU by typing in Figure 4.3.3.4-1.
UM (CR) If correct, continue to step
4010
o If the configuration is not
identical, or it is not possible
to enter the command, it indicates
an error in the PU Subsystem
or in the comunication between
the PU and the Maint. Pos.
VDU. Check the VDU.
GO TO step 6000.