DataMuseum.dk

Presents historical artifacts from the history of:

CR80 Wang WCS documentation floppies

This is an automatic "excavation" of a thematic subset of
artifacts from Datamuseum.dk's BitArchive.

See our Wiki for more about CR80 Wang WCS documentation floppies

Excavated with: AutoArchaeologist - Free & Open Source Software.


top - metrics - download

⟦aa0107aa3⟧ Wang Wps File

    Length: 3041 (0xbe1)
    Types: Wang Wps File
    Notes: Spelunked
    Names: »~ORPHAN76.08«

Derivation

└─⟦17e14ee1a⟧ Bits:30006162 8" Wang WCS floppy, CR 0237A
    └─⟦this⟧ »~ORPHAN76.08« 

WangText

…1f……00……00……00……00…L…0a……00……00…L…0c…L…0d…L…02…6…08…6…09…6…0c…6…0f…6…01…6…06…5…09…5…0e…5…02……86…1                                             …02…          …02…    …02…       

2988A/rt/  …02…CPS/TCM/005

…02…KJA/830912…02……02… 
CAMPS SITE LEVEL MAINTENANCE MANUAL
…02…Issue 1…02… CAMPS
 
 TDX TEST PROCEDURES STEP 4000-5000 (cont'd)

 STEP     PROCEDURE                    OBSERVATION/ACTION
 ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲ ̲





2988A/rt/  …02…CPS/TCM/005

…02…KJA/830912…02……02… 
CAMPS SITE LEVEL MAINTENANCE MANUAL
…02…Issue 1…02… CAMPS
 























4.3.3.4         T̲D̲X̲ ̲T̲e̲s̲t̲ ̲P̲r̲o̲c̲e̲d̲u̲r̲e̲s̲




    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *
4000                      TDX TEST  ENTRY

                          Before start of the TDX test
                          procedure, verify that

                          1.The commands typed on the Maint.Ps.VDU
                          are directed to the PU which
                          should execute the test.

                          2.The PU is offline

                          3.The PU is enabled

                          4.The PU is in Normal Mode

                          It is possible to obtain these
                          conditions e̲i̲t̲h̲e̲r̲

                          a) by commands issued from the
                          Maint.Pos. VDU via the Wath Dog
                          Subsystem

                          o̲r̲

                          b) by manual switchs settings
                          on the MAP module and a reconfiguration
                          procedure.

                          a.1) P̲U̲ ̲ ̲ ̲M̲a̲i̲n̲t̲.̲P̲o̲s̲.̲V̲D̲U̲ ̲c̲o̲m̲m̲u̲n̲i̲c̲a̲t̲i̲o̲n̲
                          ̲b̲y̲ ̲t̲h̲e̲ ̲W̲D̲ ̲C̲o̲m̲m̲a̲n̲d̲

                               PUNno, no is No of the actual
                            PU (refer to section 5.76 in
                            (*))

                          a.2) P̲U̲ ̲O̲F̲L̲I̲N̲E̲ ̲B̲Y̲ ̲T̲H̲E̲ ̲W̲D̲ ̲c̲o̲m̲m̲a̲n̲d̲:̲

                               OFLI (refer to section 5.7.7
                            in (*))

                          a.3) P̲U̲ ̲e̲n̲a̲b̲l̲e̲d̲ ̲b̲y̲ ̲t̲h̲e̲ ̲W̲D̲ ̲c̲o̲m̲m̲a̲n̲d̲:̲
                          ̲E̲N̲P̲U̲
                               (refer to section 5.7.4
                            in (*)).

                          a.4) P̲U̲ ̲ ̲n̲o̲r̲m̲a̲l̲ ̲m̲o̲d̲e̲ ̲t̲h̲e̲ ̲W̲D̲ ̲c̲o̲m̲m̲a̲n̲d̲:̲
                          ̲N̲O̲R̲M̲
                               (refer to section 5.7.9
                            in (*))

                          (*) CAMPS MINTENANCE POSITION
                          OPERATION MANUAL, Doc.No. CPS/OPM/005

    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *…86…1    …02…                     …02… …02…    …02…  …02…      
                           
                          b.1)   P̲U̲ ̲ ̲M̲a̲i̲n̲t̲.̲ ̲P̲o̲s̲.̲ ̲V̲D̲U̲ ̲c̲o̲m̲m̲u̲n̲i̲c̲a̲t̲i̲o̲n̲
                                 ̲b̲y̲ ̲r̲e̲c̲o̲n̲f̲i̲g̲u̲r̲a̲t̲i̲o̲n̲:̲

                                 It is possible to connect
                                 the Maint.Pos.VDU directly
                                 to the PU by a reconfiguration
                                 procedure. The procedure
                                 i described in step 3600
                                 - 3700 in section 4.3.3.3.

                          b.2)   P̲U̲ ̲O̲f̲f̲l̲i̲n̲e̲ ̲b̲y̲ ̲s̲w̲i̲t̲c̲h̲s̲e̲t̲t̲i̲n̲g̲

                                 The PU is taken offline
                                 by pressing the MC button
                                 situated on the front
                                 of the MAP module in the
                                 actual PU (refer to section
                                 4.5).

                          b.3)   P̲U̲ ̲e̲n̲a̲b̲l̲e̲d̲ ̲b̲y̲ ̲s̲w̲i̲c̲h̲s̲e̲t̲t̲i̲n̲g̲.̲

                                 The PU is enabled by switching
                                 the EN/DIS switch on the
                                 front of the MAP module
                                 in the actual PU to the
                                 EN position (refer to
                                 section 4.5)

                          b.4)   P̲U̲ ̲ ̲N̲o̲r̲m̲ ̲M̲o̲d̲e̲ ̲b̲y̲ ̲S̲w̲i̲t̲c̲h̲s̲e̲t̲t̲i̲n̲g̲:̲

                                 The PU is set in normal
                                 mode by switching the
                                 MAN/NRM switch on the
                                 front of the MAP module
                                 to the NRM position (refer
                                 to section 4.5)
 
    * * * * * * * * * * * * * * * * * * * * * * * * * *
    * * * * * *


4005                      Check the                                o The
                                                                     configuration
                                                                     of
                                                                     the
                                                                     PU
                                                                     should
                                                                     be
    configuration of        identical to the onfiguration
                            shown
    the PU by typing        in Figure 4.3.3.4-1.

    UM (CR)                 If correct, continue to step
                            4010

                          o If the configuration is not
                            identical, or it is not possible
                            to enter the command, it indicates
                            an error in the PU Subsystem
                            or in the comunication between
                            the PU and the Maint. Pos.
                            VDU. Check the VDU.

                                 GO TO step 6000.