|
|
DataMuseum.dkPresents historical artifacts from the history of: IBM System/36 |
This is an automatic "excavation" of a thematic subset of
See our Wiki for more about IBM System/36 Excavated with: AutoArchaeologist - Free & Open Source Software. |
top - metrics - download
Length: 57088 (0xdf00)
Notes: FORM36, MEMBER_O
Names: »##FST8 «
└─⟦edfbb8ae1⟧ Bits:30009818 AS/ENTRY - S/36 SYST SUPP PROG IDENT. S/36 PTFDK3900 FC 1991/9074/9084 Refer to Memo 36714 Product Number 5727SS6 Rel 05 3 Created 19950301 Level 01 Seq 001 of 011
└─⟦8738fec01⟧
└─⟦this⟧ ».##FST8 «
FormPointer36 {name=»B2111 «, f1=0x00, start=0x0006, length=0x03, f5=0x00, f6=0x00, f7=0x06, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ Data Communications Line Test Using BSC Format │
03│ │
04│ │
05│ Line number . . . . . . . . . . . . . . . . . . . . . . . 1-8 ␣┴┤ │
06│ │
07│ Requester or responder . . . . . . . . . . . . . . . . REQ,RES ␣␣␣┴┤ │
08│ │
09│ EBCDIC or ASCII character type . . . . . . . . . . . . . . E,A ␣┴┤ │
10│ │
11│ Review or change the line configuration? . . . . . . . . . Y,N ␣┴┤ │
12│ │
13│ │
14│ │
15│ │
16│ │
17│ Cmd7-End │
18│ │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2113 «, f1=0x00, start=0x0009, length=0x04, f5=0x00, f6=0x00, f7=0x06, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ Review or Change the Line Configuration For This Session │
03│ │
04│ │
05│ Multipoint or switched or nonswitched point-to-point . . M,S,N ␣┴┤ │
06│ │
07│ Answer tone (world trade only) . . . . . . . . . . . . . . Y,N ␣┴┤ │
08│ │
09│ Switched network backup . . . . . . . . . . . . . . . . . Y,N ␣┴┤ │
10│ │
11│ Clock provided by modem or internal clock feature . . . . M,I ␣┴┤ │
12│ │
13│ Half rate or full rate . . . . . . . . . . . . . . . . . . H,F ␣┴┤ │
14│ │
15│ Continuous carrier . . . . . . . . . . . . . . . . . . . . Y,N ␣┴┤ │
16│ │
17│ │
18│ Cmd3-Previous display Cmd7-End │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2112 «, f1=0x00, start=0x000d, length=0x03, f5=0x00, f6=0x00, f7=0x05, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ Data Communications Line Test Using BSC Format │
03│ │
04│ │
05│ Requester or responder . . . . . . . . . . . . . . . . REQ,RES ␣␣␣┴┤ │
06│ │
07│ EBCDIC or ASCII character type . . . . . . . . . . . . . . E,A ␣┴┤ │
08│ │
09│ Review or change the line configuration? . . . . . . . . . Y,N ␣┴┤ │
10│ │
11│ │
12│ │
13│ │
14│ │
15│ │
16│ │
17│ Cmd7-End │
18│ │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2121 «, f1=0x00, start=0x0010, length=0x02, f5=0x00, f6=0x00, f7=0x02, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ Multipoint Station Address Entry │
03│ │
04│ │
05│ Enter the address of this station in hexadecimal . . . . . . . ␣␣┴┤ │
06│ │
07│ │
08│ │
09│ │
10│ │
11│ │
12│ │
13│ │
14│ │
15│ │
16│ │
17│ Cmd3-Previous display Cmd7-End │
18│ │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2122A «, f1=0x00, start=0x0012, length=0x03, f5=0x00, f6=0x00, f7=0x01, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST . ␣␣│
01│ │
02│ Identification Number Entry │
03│ │
04│ │
05│ If the responder is a test center, an identification number may be needed. │
06│ │
07│ Is the data link being established with a test center that │
08│ needs an identification number? . . . . . . . . . . . . . Y,N ␣┴┤ │
09│ │
10│ │
11│ │
12│ │
13│ │
14│ │
15│ │
16│ │
17│ Cmd3-Return to test selection Cmd7-End │
18│ │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2122B «, f1=0x00, start=0x0015, length=0x04, f5=0x00, f6=0x00, f7=0x06, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ Identification Number Entry │
03│ │
04│ │
05│ If the responder is a test center, an identification number may be needed. │
06│ │
07│ Is the data link being established with a test center that │
08│ needs an identification number? . . . . . . . . . . . . . Y,N ╳␣╳ │
09│ │
10│ Branch office number . . . . . . . . . . . . . . . . . . . . . ␣␣␣┴┤ │
11│ │
12│ Security code . . . . . . . . . . . . . . . . . . . . . . . . ␣␣␣┴┤ │
13│ │
14│ │
15│ │
16│ │
17│ Cmd3-Return to test selection Cmd7-End │
18│ │
19│ │
20│ │
21│ │
22│ │
23│╳Security code not valid ╳ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2123 «, f1=0x00, start=0x0019, length=0x05, f5=0x00, f6=0x00, f7=0x01, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ Requester Message Selection (XX Value) │
03│ │
04│ Select one of the following: │
05│ │
06│ 1. XX=00 (Requester transmits user entered data) │
07│ 2. XX=01 (Requester receives user entered data) │
08│ 3. XX=02 (256 bytes, 0 through 255 transparent mode) │
09│ 4. XX=04 (All EBCDIC characters excluding DLC control characters) │
10│ 5. XX=14 (36 characters: A through Z and 0 through 9) │
11│ 6. XX=15 (74 bytes of '00') │
12│ 7. XX=16 (40 bytes of 'AA' and 40 bytes of '55') │
13│ 8. XX=19 (280 bytes of '00' and 10 bytes SYN transparent mode) │
14│ │
15│ Option: ␣┴┤ │
16│ │
17│ Cmd3-Previous display Cmd7-End │
18│ │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2124 «, f1=0x00, start=0x001e, length=0x03, f5=0x00, f6=0x00, f7=0x01, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ Requester Message Selection (XX Value) │
03│ │
04│ │
05│ Select one of the following: │
06│ │
07│ 1. XX=00 (Requester transmits user entered data) │
08│ 2. XX=01 (Requester receives user entered data) │
09│ 3. XX=05 (All ASCII characters excluding DLC control characters) │
10│ 4. XX=06 (36 characters: A through Z and 0 through 9) │
11│ │
12│ Option: ␣┴┤ │
13│ │
14│ │
15│ │
16│ │
17│ Cmd3-Previous display Cmd7-End │
18│ │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2125 «, f1=0x00, start=0x0021, length=0x06, f5=0x00, f6=0x00, f7=0x1e, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ Data Entry For XX Messages 00 or 01 │
03│ │
04│ Conditions: │
05│ - STX (02) must be first data byte except for transparent mode. │
06│ - ETX (03) must end data. │
07│ - Data may be any length from 2 to 15 (2 bytes needed for STX and ETX). │
08│ │
09│ ╳ Note: TRANSPARENT mode is not supported for BSC ASCII. If you are running ╳│
10│ ╳ BSC ASCII you must ignore the extra CONDITIONS below and key in data as ╳│
11│ ╳ mentioned above. ╳│
12│ │
13│ Extra conditions needed to run transparent mode: │
14│ │
15│ - DLE (10) must precede STX for transparent mode. │
16│ - DLE need not precede ETX for transparent mode because microcode inserts │
17│ DLE. │
18│ │
19│ Enter data in hexadecimal. . . . . . . . ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣┴┤ │
20│ │
21│ Cmd3-Previous display Cmd7-End │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2126 «, f1=0x00, start=0x0027, length=0x03, f5=0x00, f6=0x00, f7=0x03, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ Message Count Entry │
03│ │
04│ │
05│ XX message selected is - - - - - - - - - - - - - - - - - - - - ␣␣ │
06│ │
07│ Enter YY count. (number of times to transmit message) . 1-99 ␣␣┴┤ │
08│ │
09│ Continuously loop on the above XX and YY values? . . . . . Y,N ␣┴┤ │
10│ │
11│ │
12│ │
13│ │
14│ │
15│ │
16│ │
17│ Cmd3-Previous display Cmd7-End │
18│ │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2127 «, f1=0x00, start=0x002a, length=0x03, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ Switched Line │
03│ │
04│ │
05│ This line is switched. Perform the following steps: │
06│ 1. Establish the data link. │
07│ 2. Press the Enter key. │
08│ │
09│ │
10│ │
11│ │
12│ │
13│ │
14│ │
15│ │
16│ │
17│ Cmd3-Return to message selection Cmd7-End │
18│ │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2128 «, f1=0x00, start=0x002d, length=0x04, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ Switched Line │
03│ │
04│ │
05│ This line is switched. Perform the following steps: │
06│ 1. Establish the data link. │
07│ 2. Press the Enter key. DTR will become active. │
08│ 3. Replace the telephone receiver. │
09│ │
10│ │
11│ │
12│ │
13│ │
14│ │
15│ │
16│ │
17│ Cmd3-Return to message selection Cmd7-End │
18│ │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2129 «, f1=0x00, start=0x0031, length=0x05, f5=0x00, f6=0x00, f7=0x1c, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ Autocall Telephone Number Entry │
03│ │
04│ │
05│ To automatically dial, perform the following steps: │
06│ 1. Enter only the necessary digits, SEP or EON characters. │
07│ Use a ' character to represent a SEP character. │
08│ Use a * character to represent an EON character. │
09│ Enter the digits and/or characters . . . . . . . . . . . │
10│ . . . . . . . . . . . . . . . . . . ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣┴┤ │
11│ 2. Press the Enter key. │
12│ │
13│ To dial by hand, perform the following steps: │
14│ 1. Dial the number. │
15│ 2. Press the Enter key. │
16│ │
17│ │
18│ Cmd3-Return to message selection Cmd7-End Help-More information │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2129H «, f1=0x00, start=0x0036, length=0x07, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ Help for Autocall Telephone Number Entry │
03│ │
04│ │
05│ SEP character use: │
06│ - A SEP character is inserted in a telephone number to separate digits dialed│
07│ to different telephone exchanges. │
08│ - If the SEP trap is not configured, a SEP character causes the autocall unit│
09│ to stop dialing digits until the next telephone exchange signals ready by │
10│ sending a second dial tone. │
11│ - If the SEP trap is configured, a SEP character will cause a 3-second pause │
12│ before the next digit is dialed. │
13│ │
14│ EON character use: │
15│ - An EON character is used with an autocall unit that cannot recognize an │
16│ answer tone signal. │
17│ - An EON character is placed at the end of a telephone number to indicate to │
18│ the autocall unit that all digits have been dialed. │
19│ - If the EON trap is configured the EON will not be used. │
20│ │
21│ │
22│ Enter-Exit help text Cmd7-End │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B21210 «, f1=0x00, start=0x003d, length=0x03, f5=0x00, f6=0x00, f7=0x18, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ X.21 Call Number Entry │
03│ │
04│ │
05│ X.21 call number . . . . . . . . . . . . . . . ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣┴┤ │
06│ │
07│ ╳Valid characters are: 0 1 2 3 4 5 6 7 8 9 . - , / * ╳ │
08│ │
09│ │
10│ ╳ If this line is direct call line then do not key in any numbers and ╳ │
11│ ╳ press Enter key ╳ │
12│ │
13│ │
14│ │
15│ │
16│ │
17│ Cmd3-Return to message selection Cmd7-End │
18│ │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B21211 «, f1=0x00, start=0x0040, length=0x03, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ Requester is Active │
03│ │
04│ │
05│ XX message selected is - - - - - - - - - - - - - - - - - - - - ␣␣ │
06│ │
07│ YY count selected is - - - - - - - - - - - - - - - - - - - - - ␣␣ │
08│ │
09│ │
10│ │
11│ │
12│ │
13│ │
14│ │
15│ │
16│ │
17│ Cmd7-End Cmd19-Cancel requester operation │
18│ (May need 33 seconds for Cmd7 or Cmd19 command to complete.) │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B21212 «, f1=0x00, start=0x0043, length=0x02, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ ╳ Requester Operation Ended With no Errors ╳ │
03│ │
04│ │
05│ XX message selected was - - - - - - - - - - - - - - - - - - - ␣␣ │
06│ │
07│ YY count selected was - - - - - - - - - - - - - - - - - - - - ␣␣ │
08│ │
09│ │
10│ │
11│ │
12│ │
13│ │
14│ │
15│ │
16│ │
17│ Enter-Return to message selection Cmd7-End │
18│ │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2131 «, f1=0x00, start=0x0045, length=0x02, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ │
03│ │
04│ │
05│ │
06│ │
07│ │
08│ │
09│ Responder is active. │
10│ │
11│ │
12│ │
13│ │
14│ │
15│ │
16│ │
17│ Cmd7-End Cmd19-Cancel responder operation │
18│ (May need 33 seconds for Cmd7 or Cmd19 command to complete.) │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2133 «, f1=0x00, start=0x0047, length=0x02, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ │
03│ │
04│ │
05│ │
06│ │
07│ │
08│ │
09│ Responder is executing a test request. │
10│ │
11│ │
12│ │
13│ │
14│ │
15│ │
16│ │
17│ Cmd7-End Cmd19-Cancel responder operation │
18│ (May need 33 seconds for Cmd7 or Cmd19 command to complete.) │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2132 «, f1=0x00, start=0x0049, length=0x03, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ Responder is Active │
03│ │
04│ │
05│ A response has been generated and no errors were detected. │
06│ │
07│ │
08│ XX message - - - - - - - - - - - - - - - - - - - - - - - - - - ␣␣ │
09│ │
10│ YY count - - - - - - - - - - - - - - - - - - - - - - - - - - - ␣␣ │
11│ │
12│ │
13│ │
14│ │
15│ │
16│ │
17│ Cmd7-End Cmd19-Cancel responder operation. │
18│ (May need 33 seconds for Cmd7 or Cmd19 command to complete.) │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2211 «, f1=0x00, start=0x004c, length=0x03, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ Line Selected is in Use │
03│ │
04│ │
05│ Another program is using this line. The other program must release the line │
06│ before the online test can use the line. │
07│ │
08│ │
09│ │
10│ │
11│ │
12│ │
13│ │
14│ │
15│ │
16│ │
17│ Enter-Return to test selection Cmd7-End │
18│ │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2212 «, f1=0x00, start=0x004f, length=0x03, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ Selected Line Not Configured │
03│ │
04│ │
05│ The communications line selected is not configured. │
06│ │
07│ The line must be configured before the online test can use it. │
08│ │
09│ │
10│ │
11│ │
12│ │
13│ │
14│ │
15│ │
16│ │
17│ Enter-Return to test selection Cmd7-End │
18│ │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2212SD «, f1=0x00, start=0x0052, length=0x02, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ BSC configuration is not supported on this system. │
03│ │
04│ BSC line must be configured before the on line test can be run. │
05│ │
06│ │
07│ │
08│ │
09│ │
10│ │
11│ │
12│ │
13│ │
14│ │
15│ │
16│ │
17│ Enter-Return to end test Cmd7-End │
18│ │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2213 «, f1=0x00, start=0x0054, length=0x03, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ Selection Error │
03│ │
04│ │
05│ This test does not support the configuration of the line selected. │
06│ │
07│ │
08│ │
09│ │
10│ │
11│ │
12│ │
13│ │
14│ │
15│ │
16│ │
17│ Enter-Return to test selection Cmd7-End │
18│ │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2231 «, f1=0x00, start=0x0057, length=0x03, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ Selection Error │
03│ │
04│ │
05│ Multipoint responder is not available on this system. │
06│ │
07│ Change the configuration to point-to-point before attempting the test again. │
08│ │
09│ │
10│ │
11│ │
12│ │
13│ │
14│ │
15│ │
16│ │
17│ Enter-Return to test selection Cmd7-End │
18│ │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2311 «, f1=0x00, start=0x005a, length=0x04, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ Error On Test Initialization │
03│ │
04│ │
05│ A CRC/LRC/VRC data check error was detected. Attempt the test again. If │
06│ this error has occurred several times, suspect a temporary network problem. │
07│ │
08│ │
09│ │
10│ │
11│ │
12│ │
13│ │
14│ │
15│ │
16│ │
17│ Enter-Start test again Cmd7-End │
18│ │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2312 «, f1=0x00, start=0x005e, length=0x04, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ Error On Test Initialization │
03│ │
04│ │
05│ A transmit adapter check error was detected. A data underrun has occurred. │
06│ Attempt the test again. If this error has occurred several times, suspect a │
07│ problem with one of the following: │
08│ - Line speed(s) may exceed specifications. │
09│ - Hardware problems exist, run internal diagnostics. │
10│ │
11│ │
12│ │
13│ │
14│ │
15│ │
16│ │
17│ Enter-Start test again Cmd7-End │
18│ │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2313 «, f1=0x00, start=0x0062, length=0x04, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ Error on Test Initialization │
03│ │
04│ │
05│ A receive adapter check error was detected. A data overrun has occurred. │
06│ Attempt the test again. If this error has occurred several times, suspect │
07│ a problem with one of the following: │
08│ - Line speed(s) may exceed specifications. │
09│ - Hardware problems exist, run internal diagnostics. │
10│ │
11│ │
12│ │
13│ │
14│ │
15│ │
16│ │
17│ Enter-Start test again Cmd7-End │
18│ │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2314 «, f1=0x00, start=0x0066, length=0x04, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ Error On Test Initialization │
03│ │
04│ │
05│ An abortive disconnect error was detected. One of the following is the │
06│ probable cause: │
07│ - The remote device disconnected the data link. │
08│ - No transmit clock. │
09│ - CTS did not become active. │
10│ │
11│ │
12│ │
13│ │
14│ │
15│ │
16│ │
17│ Enter-Return to test selection Cmd7-End │
18│ │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2315 «, f1=0x00, start=0x006a, length=0x04, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ Error On Test Initialization │
03│ │
04│ │
05│ A NO DSR error has occurred. One of the following is the probable cause: │
06│ - DSR was not active. │
07│ - No transmit clock. │
08│ - CTS did not become active. │
09│ │
10│ │
11│ │
12│ │
13│ │
14│ │
15│ │
16│ │
17│ Enter-Return to test selection Cmd7-End │
18│ │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2321 «, f1=0x00, start=0x006e, length=0x05, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ Error On Test Initialization │
03│ │
04│ │
05│ No ACK was correctly received by the requester after transmitting an ENQ. The│
06│ test attempted the transmission of the ENQ seven times. One of the following│
07│ is the probable cause: │
08│ - The responder was not ready. │
09│ - The responder transmitted something other than an ACK. │
10│ - The data link was not established. │
11│ - The data link is failing to transfer the ENQ or ACK. │
12│ │
13│ Determine and correct the problem before attempting the test again. │
14│ │
15│ │
16│ │
17│ Enter-Return to message selection Cmd7-End │
18│ │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2322 «, f1=0x00, start=0x0073, length=0x05, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ Error On Test Initialization │
03│ │
04│ │
05│ The responder failed to acknowledge the request for test message with an ACK. │
06│ Attempt the test again. One of the following is the probable cause: │
07│ - The responder did not correctly receive the request for test message. │
08│ - The responder did not transmit within 3 seconds after the request for │
09│ test message was transmitted. │
10│ - The responder transmitted something other than an ACK. │
11│ - The data link failed to transfer the request for test message or the ACK. │
12│ - Check for proper CTS delay. │
13│ │
14│ │
15│ │
16│ │
17│ Enter-Return to message selection Cmd7-End │
18│ │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2323 «, f1=0x00, start=0x0078, length=0x05, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ Error On test Initialization │
03│ │
04│ │
05│ The responder failed to answer with an ENQ to the EOT transmitted by the │
06│ requester. Attempt the test again. If the error has occurred several │
07│ times, suspect a problem with one of the following: │
08│ - The responder did not correctly receive the EOT. │
09│ - The responder did not transmit within 3 seconds after the EOT was │
10│ transmitted. │
11│ - The responder transmitted something other than an ENQ. │
12│ - The data link failed to transfer either the EOT or ENQ. │
13│ │
14│ │
15│ │
16│ │
17│ Enter-Return to message selection Cmd7-End │
18│ │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2324 «, f1=0x00, start=0x007d, length=0x04, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ Error On Test Initialization │
03│ │
04│ │
05│ An ASCII character that was not valid was detected. The probable cause is │
06│ invalid ASCII data entered for either test messages 00 or 01. │
07│ │
08│ │
09│ Enter only valid ASCII data for test message 00 or 01. Refer to the ASCII │
10│ conversion chart in the general MIM. │
11│ │
12│ │
13│ │
14│ │
15│ │
16│ │
17│ Enter-Return to message selection Cmd7-End │
18│ │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2331 «, f1=0x00, start=0x0081, length=0x03, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ Request For Test Message Not Valid │
03│ │
04│ │
05│ Either the XX message or the YY count transmitted by the requester was not │
06│ valid. │
07│ │
08│ XX message requested - - - - - - - - - - - - - - - - - - - - ␣␣ │
09│ │
10│ YY count requested - - - - - - - - - - - - - - - - - - - - - ␣␣ │
11│ │
12│ XX or YY count must be corrected by the requester. │
13│ │
14│ │
15│ │
16│ │
17│ Enter-Start test again Cmd7-End │
18│ │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2332 «, f1=0x00, start=0x0084, length=0x05, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ Error On Test Initialization │
03│ │
04│ │
05│ The requester failed to answer an ACK0 with a request for test message. │
06│ Attempt the test again. One of the following is the probable cause: │
07│ - The requester did not correctly receive the ACK0. │
08│ - The requester did not transmit within 3 seconds after the ACK0 was │
09│ transmitted. │
10│ - The requester transmitted something other than the request for test │
11│ message. │
12│ - The data link failed to transfer the ACK0 or the request for test │
13│ message. │
14│ │
15│ │
16│ │
17│ Enter-Start test again Cmd7-End │
18│ │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2333 «, f1=0x00, start=0x0089, length=0x04, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ Error On Test Initialization │
03│ │
04│ │
05│ The requester failed to answer an ACK1 with an EOT. Attempt the test again. │
06│ One of the following is the probable cause: │
07│ - The requester did not correctly receive the ACK1. │
08│ - The requester did not transmit within 3 seconds after the ACK1 was │
09│ transmitted. │
10│ - The requester transmitted something other than an EOT. │
11│ - The data link failed to transfer the ACK1 or the EOT. │
12│ │
13│ │
14│ │
15│ │
16│ │
17│ Enter-Start test again Cmd7-End │
18│ │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2334 «, f1=0x00, start=0x008d, length=0x05, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ Error On Test Initialization │
03│ │
04│ │
05│ No ACK was correctly received by the responder after transmitting an ENQ. │
06│ The test attempted the transmission of the ENQ seven times. One of the │
07│ following is the probable cause: │
08│ - The data link was lost. │
09│ - The requester transmitted something other than an ACK. │
10│ - The data link is failing to transfer the ENQ or the ACK. │
11│ │
12│ Determine and correct the problem before attempting the test again. │
13│ │
14│ │
15│ │
16│ │
17│ Enter-Start test again Cmd7-End │
18│ │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2411 «, f1=0x00, start=0x0092, length=0x04, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ Permanent Error Detected in Test Mode │
03│ │
04│ │
05│ An abortive disconnect error was detected. One of the following is the │
06│ probable cause: │
07│ - The remote device disconnected the data link. │
08│ - No transmit clock. │
09│ - CTS did not become active. │
10│ │
11│ │
12│ │
13│ │
14│ │
15│ │
16│ │
17│ Enter-Return to test selection Cmd7-End │
18│ │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2412 «, f1=0x00, start=0x0096, length=0x03, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ Permanent Error Detected in Test Mode │
03│ │
04│ │
05│ A NO DSR error has occurred. One of the following is the probable cause: │
06│ - DSR was not active. │
07│ - No transmit clock. │
08│ - CTS did not become active. │
09│ │
10│ │
11│ │
12│ │
13│ │
14│ │
15│ │
16│ │
17│ Enter-Return to test selection Cmd7-End │
18│ │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2413 «, f1=0x00, start=0x0099, length=0x03, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ Error Detected in Test Mode │
03│ │
04│ │
05│ The remote device has a problem and is not able to receive the test message │
06│ transmitted by this device. 25 WACKS have been received. │
07│ │
08│ Determine and fix the remote device's problem before attempting the test │
09│ again. │
10│ │
11│ │
12│ │
13│ │
14│ │
15│ │
16│ │
17│ Enter-Start test again Cmd7-End │
18│ │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2414 «, f1=0x00, start=0x009c, length=0x03, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ Permanent Error Detected in Test Mode │
03│ │
04│ │
05│ The remote device has not transmitted a test message in 21 seconds. One of │
06│ the following is the probable cause: │
07│ - The remote device operation has stopped. │
08│ - The data link is failing to transfer the test message or the ACK. │
09│ │
10│ │
11│ │
12│ │
13│ │
14│ │
15│ │
16│ │
17│ Enter-Start test again Cmd7-End │
18│ │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2421 «, f1=0x00, start=0x009f, length=0x08, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ Message Error │
02│ The message received was not the message requested. Data received is │
03│ displayed in reverse image, data requested is not reverse imaged. │
04│ │
05│ ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣ │
06│ ╳␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣╳ │
07│ ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣ │
08│ ╳␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣╳ │
09│ ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣ │
10│ ╳␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣╳ │
11│ ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣ │
12│ ╳␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣╳ │
13│ ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣ │
14│ ╳␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣╳ │
15│ ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣ │
16│ ╳␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣╳ │
17│ ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣ │
18│ ╳␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣╳ │
19│ ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣ │
20│ ╳␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣╳ │
21│ │
22│ Enter-Return to message selection Cmd7-End │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2422 «, f1=0x00, start=0x00a7, length=0x04, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ Temporary Errors Detected in Test Mode │
03│ │
04│ │
05│ Message requested (XX value) - - - - - - - - - - - - - - - - - ␣␣ │
06│ │
07│ Message count requested (YY value) - - - - - - - - - - - - - - ␣␣ │
08│ │
09│ Valid messages actually received - - - - - - - - - - - - - - - ␣␣␣ │
10│ │
11│ CRC/LRC/VRC errors detected - - - - - - - - - - - - - - - - - ␣␣␣ │
12│ │
13│ Transmit adapter checks detected - - - - - - - - - - - - - - - ␣␣␣ │
14│ │
15│ Receive adapter checks detected - - - - - - - - - - - - - - - ␣␣␣ │
16│ │
17│ │
18│ Enter-Start test again Cmd5-Display data received on last CRC/LRC/VRC error │
19│ Cmd7-End Cmd19-Cancel requester operation │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2423 «, f1=0x00, start=0x00ab, length=0x08, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ Data Error │
02│ The data received had a CRC/LRC/VRC data error. Data received is displayed │
03│ in reverse image, data requested is not reverse imaged. If the program was │
04│ looping on XX and YY values, looping has been stopped. │
05│ ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣ │
06│ ╳␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣╳ │
07│ ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣ │
08│ ╳␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣╳ │
09│ ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣ │
10│ ╳␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣╳ │
11│ ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣ │
12│ ╳␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣╳ │
13│ ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣ │
14│ ╳␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣╳ │
15│ ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣ │
16│ ╳␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣╳ │
17│ ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣ │
18│ ╳␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣╳ │
19│ ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣ │
20│ ╳␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣╳ │
21│ │
22│ Enter-Start test again Cmd7-End │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2424 «, f1=0x00, start=0x00b3, length=0x02, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ │
03│ │
04│ │
05│ │
06│ │
07│ │
08│ │
09│ No CRC/LRC/VRC data checks have occurred. │
10│ │
11│ │
12│ │
13│ │
14│ │
15│ │
16│ │
17│ Enter-Continue Cmd7-End │
18│ │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2431 «, f1=0x00, start=0x00b5, length=0x05, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ Response Complete │
03│ │
04│ A response has been generated and errors were detected. │
05│ │
06│ Responder is active. │
07│ │
08│ XX message - - - - - - - - - - - - - - - - - - - - - - - - - - ␣␣ │
09│ YY count - - - - - - - - - - - - - - - - - - - - - - - - - - - ␣␣ │
10│ Receive time-outs detected - - - - - - - - - - - - - - - - - - ␣␣ │
11│ CRC/LRC/VRC errors detected - - - - - - - - - - - - - - - - - ␣␣ │
12│ Transmit adapter checks detected - - - - - - - - - - - - - - - ␣␣ │
13│ Receive adapter checks detected - - - - - - - - - - - - - - - ␣␣ │
14│ │
15│ │
16│ │
17│ Cmd7-End Cmd19-Cancel responder operation │
18│ (May need 33 seconds for Cmd7 or Cmd19 command to complete.) │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2511 «, f1=0x00, start=0x00ba, length=0x04, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ X.21 Dial-up Error │
03│ │
04│ A call progress signal error occurred. │
05│ │
06│ │
07│ The network canceled the data link by sending a negative call progress signal.│
08│ │
09│ The call progress signal │
10│ was - - - - - - - - - - - - - ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣ │
11│ │
12│ Perform the correction that is suitable for the call progress signal. │
13│ │
14│ │
15│ │
16│ │
17│ Enter-Return to call-number entry Cmd3-Return to message selection │
18│ Cmd7-End │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2512 «, f1=0x00, start=0x00be, length=0x03, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ X.21 Dial-up Error │
03│ │
04│ A T1 time-out error occurred. │
05│ │
06│ │
07│ │
08│ The network did not respond to the call request. │
09│ │
10│ Attempt the dial-up again. │
11│ │
12│ │
13│ │
14│ │
15│ │
16│ │
17│ Enter-Return to call-number entry Cmd3-Return to message selection │
18│ Cmd7-End │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2513 «, f1=0x00, start=0x00c1, length=0x03, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ X.21 Dial-up Error │
03│ │
04│ A T2 time-out error occurred. │
05│ │
06│ │
07│ │
08│ The network did not respond to the selection signal. │
09│ │
10│ Attempt the dial-up again. │
11│ │
12│ │
13│ │
14│ │
15│ │
16│ │
17│ Enter-Return to call-number entry Cmd3-Return to message selection │
18│ Cmd7-End │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2514 «, f1=0x00, start=0x00c4, length=0x03, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ X.21 Dial-up Error │
03│ │
04│ A T3A time-out error occurred. │
05│ │
06│ │
07│ The network responded to the selection signal with information provided by │
08│ the DCE, but did not signal ready for data. │
09│ │
10│ Attempt the dial-up again. │
11│ │
12│ │
13│ │
14│ │
15│ │
16│ │
17│ Enter-Return to call-number entry Cmd3-Return to message selection │
18│ Cmd7-End │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2515 «, f1=0x00, start=0x00c7, length=0x03, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ X.21 Dial-up Error │
03│ │
04│ A T3B time-out error occurred. │
05│ │
06│ │
07│ The network responded with a group 0 call progress signal, but did not signal │
08│ ready for data. │
09│ │
10│ The call progress signal │
11│ was - - - - - - - - - - - - - ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣ │
12│ │
13│ │
14│ │
15│ │
16│ │
17│ Enter-Return to call-number entry Cmd3-Return to message selection │
18│ Cmd7-End │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2516 «, f1=0x00, start=0x00ca, length=0x03, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ X.21 Dial-up Error │
03│ │
04│ A parity error occurred. │
05│ │
06│ │
07│ The attempt to establish a data link failed because a parity error was │
08│ detected on an incoming character. │
09│ │
10│ Attempt the dial-up again. │
11│ │
12│ │
13│ │
14│ │
15│ │
16│ │
17│ Enter-Return to call-number entry Cmd3-Return to message selection │
18│ Cmd7-End │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2517 «, f1=0x00, start=0x00cd, length=0x03, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ X.21 Dial-up Error │
03│ │
04│ A DCE clear error occurred. │
05│ │
06│ │
07│ The network canceled the dial-up by performing a DCE clear. │
08│ │
09│ Attempt the dial-up again. │
10│ │
11│ │
12│ │
13│ │
14│ │
15│ │
16│ │
17│ Enter-Return to call-number entry Cmd3-Return to message selection │
18│ Cmd7-End │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2518 «, f1=0x00, start=0x00d0, length=0x04, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ X.21 Dial-up Error │
03│ │
04│ A DCE not ready error occurred. │
05│ │
06│ │
07│ The data link was not established because the DCE was not ready. │
08│ │
09│ Ensure that the DCE is powered up and connected to the system before │
10│ attempting the dial-up again. │
11│ │
12│ │
13│ │
14│ │
15│ │
16│ │
17│ Enter-Return to call-number entry Cmd3-Return to message selection │
18│ Cmd7-End │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2519 «, f1=0x00, start=0x00d4, length=0x03, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ X.21 Dial-up Error . │
03│ │
04│ An adapter check error occurred. │
05│ │
06│ │
07│ An underrun or overrun occurred while the dial-up was in progress. │
08│ │
09│ Attempt the dial-up again. │
10│ │
11│ │
12│ │
13│ │
14│ │
15│ │
16│ │
17│ Enter-Return to call-number entry Cmd3-Return to message selection │
18│ Cmd7-End │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2611 «, f1=0x00, start=0x00d7, length=0x03, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ Autocall Error │
03│ │
04│ An error occurred while automatically dialing. │
05│ │
06│ │
07│ The error was a ␣␣␣ error and was ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣ │
08│ │
09│ │
10│ │
11│ │
12│ │
13│ │
14│ │
15│ │
16│ │
17│ Enter-Return to telephone number entry Cmd3-Return to message selection │
18│ Cmd7-End │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2214 «, f1=0x00, start=0x00da, length=0x02, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ Not enough Communication controller storage. │
03│ │
04│ │
05│ An X.21 switched line requires a minimum of 32K words of Communication │
06│ controller storage. │
07│ │
08│ │
09│ │
10│ │
11│ │
12│ │
13│ │
14│ │
15│ │
16│ │
17│ Enter-Return to test selection Cmd7-End │
18│ │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»SLOTMSG «, f1=0x00, start=0x00dc, length=0x02, f5=0x00, f6=0x00, f7=0x05, f8=0x00, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ ╳ BSCTEST ╳ │
01│ │
02│ ╳ BSC online test ╳ │
03│ │
04│ │
05│ ╳Location of DIAG23 or DIAG43 or DSKT03 or DSKT11 or DSKT61 │
06│ diskette . . . . . . . . . . . . . . . S1,S2,S3,M1.nn,M2.nn S1 ┴┤ │
07│ │
08│ │
09│ │
10│ │
11│ │
12│ │
13│ │
14│ │
15│ │
16│ │
17│ │
18│ │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2129C «, f1=0x00, start=0x00de, length=0x01, f5=0x00, f6=0x00, f7=0x00, f8=0x80, f9=0000000000000000}
┌────────────────────────────────────────────────────────────────────────────────┐
00│ BSC ONLINE TEST ␣␣│
01│ │
02│ │
03│ │
04│ │
05│ │
06│ │
07│ │
08│ │
09│ │
10│ │
11│ ╳ The dial-up is proceeding. ╳ │
12│ │
13│ │
14│ │
15│ │
16│ │
17│ │
18│ │
19│ │
20│ │
21│ │
22│ │
23│ │
24│ │
25│ │
26│ │
27│ │
└────────────────────────────────────────────────────────────────────────────────┘