DataMuseum.dk

Presents historical artifacts from the history of:

IBM System/36

This is an automatic "excavation" of a thematic subset of
artifacts from Datamuseum.dk's BitArchive.

See our Wiki for more about IBM System/36

Excavated with: AutoArchaeologist - Free & Open Source Software.


top - metrics - download

⟦8c84beba7⟧

    Length: 57088 (0xdf00)
    Notes: FORM36, MEMBER_O
    Names: »##FST8  «

Derivation

└─⟦edfbb8ae1⟧ Bits:30009818 AS/ENTRY - S/36 SYST SUPP PROG IDENT. S/36 PTFDK3900 FC 1991/9074/9084 Refer to Memo 36714 Product Number 5727SS6 Rel 05 3 Created 19950301 Level 01 Seq 001 of 011
    └─⟦8738fec01⟧ 
        └─⟦this⟧ ».##FST8  « 

S/36 Forms

FormPointer36 {name=»B2111   «, f1=0x00, start=0x0006, length=0x03, f5=0x00, f6=0x00, f7=0x06, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                Data Communications Line Test Using BSC Format                  │
03│                                                                                │
04│                                                                                │
05│  Line number  . . . . . . . . . . . . . . . . . . . . . . . 1-8 ␣┴┤            │
06│                                                                                │
07│  Requester or responder . . . . . . . . . . . . . . . . REQ,RES ␣␣␣┴┤          │
08│                                                                                │
09│  EBCDIC or ASCII character type . . . . . . . . . . . . . . E,A ␣┴┤            │
10│                                                                                │
11│  Review or change the line configuration? . . . . . . . . . Y,N ␣┴┤            │
12│                                                                                │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Cmd7-End                                                                       │
18│                                                                                │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2113   «, f1=0x00, start=0x0009, length=0x04, f5=0x00, f6=0x00, f7=0x06, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│            Review or Change the Line Configuration For This Session            │
03│                                                                                │
04│                                                                                │
05│  Multipoint or switched or nonswitched point-to-point . . M,S,N ␣┴┤            │
06│                                                                                │
07│  Answer tone (world trade only) . . . . . . . . . . . . . . Y,N ␣┴┤            │
08│                                                                                │
09│  Switched network backup  . . . . . . . . . . . . . . . . . Y,N ␣┴┤            │
10│                                                                                │
11│  Clock provided by modem or internal clock feature  . . . . M,I ␣┴┤            │
12│                                                                                │
13│  Half rate or full rate . . . . . . . . . . . . . . . . . . H,F ␣┴┤            │
14│                                                                                │
15│  Continuous carrier . . . . . . . . . . . . . . . . . . . . Y,N ␣┴┤            │
16│                                                                                │
17│                                                                                │
18│ Cmd3-Previous display   Cmd7-End                                               │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2112   «, f1=0x00, start=0x000d, length=0x03, f5=0x00, f6=0x00, f7=0x05, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                Data Communications Line Test Using BSC Format                  │
03│                                                                                │
04│                                                                                │
05│  Requester or responder . . . . . . . . . . . . . . . . REQ,RES ␣␣␣┴┤          │
06│                                                                                │
07│  EBCDIC or ASCII character type . . . . . . . . . . . . . . E,A ␣┴┤            │
08│                                                                                │
09│  Review or change the line configuration? . . . . . . . . . Y,N ␣┴┤            │
10│                                                                                │
11│                                                                                │
12│                                                                                │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Cmd7-End                                                                       │
18│                                                                                │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2121   «, f1=0x00, start=0x0010, length=0x02, f5=0x00, f6=0x00, f7=0x02, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                        Multipoint Station Address Entry                        │
03│                                                                                │
04│                                                                                │
05│  Enter the address of this station in hexadecimal . . . . . . . ␣␣┴┤           │
06│                                                                                │
07│                                                                                │
08│                                                                                │
09│                                                                                │
10│                                                                                │
11│                                                                                │
12│                                                                                │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Cmd3-Previous display   Cmd7-End                                               │
18│                                                                                │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2122A  «, f1=0x00, start=0x0012, length=0x03, f5=0x00, f6=0x00, f7=0x01, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST              .                ␣␣│
01│                                                                                │
02│                          Identification Number Entry                           │
03│                                                                                │
04│                                                                                │
05│  If the responder is a test center, an identification number may be needed.    │
06│                                                                                │
07│  Is the data link being established with a test center that                    │
08│   needs an identification number? . . . . . . . . . . . . . Y,N ␣┴┤            │
09│                                                                                │
10│                                                                                │
11│                                                                                │
12│                                                                                │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Cmd3-Return to test selection   Cmd7-End                                       │
18│                                                                                │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2122B  «, f1=0x00, start=0x0015, length=0x04, f5=0x00, f6=0x00, f7=0x06, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                          Identification Number Entry                           │
03│                                                                                │
04│                                                                                │
05│  If the responder is a test center, an identification number may be needed.    │
06│                                                                                │
07│  Is the data link being established with a test center that                    │
08│   needs an identification number? . . . . . . . . . . . . . Y,N ╳␣╳            │
09│                                                                                │
10│  Branch office number . . . . . . . . . . . . . . . . . . . . . ␣␣␣┴┤          │
11│                                                                                │
12│  Security code  . . . . . . . . . . . . . . . . . . . . . . . . ␣␣␣┴┤          │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Cmd3-Return to test selection   Cmd7-End                                       │
18│                                                                                │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│╳Security code not valid                               ╳                        │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2123   «, f1=0x00, start=0x0019, length=0x05, f5=0x00, f6=0x00, f7=0x01, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                    Requester Message Selection (XX Value)                      │
03│                                                                                │
04│  Select one of the following:                                                  │
05│                                                                                │
06│    1. XX=00  (Requester transmits user entered data)                           │
07│    2. XX=01  (Requester receives user entered data)                            │
08│    3. XX=02  (256 bytes, 0 through 255 transparent mode)                       │
09│    4. XX=04  (All EBCDIC characters excluding DLC control characters)          │
10│    5. XX=14  (36 characters: A through Z and 0 through 9)                      │
11│    6. XX=15  (74 bytes of '00')                                                │
12│    7. XX=16  (40 bytes of 'AA' and 40 bytes of '55')                           │
13│    8. XX=19  (280 bytes of '00' and 10 bytes SYN transparent mode)             │
14│                                                                                │
15│ Option:  ␣┴┤                                                                   │
16│                                                                                │
17│ Cmd3-Previous display   Cmd7-End                                               │
18│                                                                                │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2124   «, f1=0x00, start=0x001e, length=0x03, f5=0x00, f6=0x00, f7=0x01, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                     Requester Message Selection (XX Value)                     │
03│                                                                                │
04│                                                                                │
05│ Select one of the following:                                                   │
06│                                                                                │
07│    1. XX=00  (Requester transmits user entered data)                           │
08│    2. XX=01  (Requester receives user entered data)                            │
09│    3. XX=05  (All ASCII characters excluding DLC control characters)           │
10│    4. XX=06  (36 characters: A through Z and 0 through 9)                      │
11│                                                                                │
12│ Option:  ␣┴┤                                                                   │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Cmd3-Previous display   Cmd7-End                                               │
18│                                                                                │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2125   «, f1=0x00, start=0x0021, length=0x06, f5=0x00, f6=0x00, f7=0x1e, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                      Data Entry For XX Messages 00 or 01                       │
03│                                                                                │
04│  Conditions:                                                                   │
05│   - STX (02) must be first data byte except for transparent mode.              │
06│   - ETX (03) must end data.                                                    │
07│   - Data may be any length from 2 to 15 (2 bytes needed for STX and ETX).      │
08│                                                                                │
09│   ╳ Note: TRANSPARENT mode is not supported for BSC ASCII. If you are running ╳│
10│   ╳ BSC ASCII you must ignore the extra CONDITIONS below and key in data as   ╳│
11│   ╳ mentioned above.                                                          ╳│
12│                                                                                │
13│  Extra conditions needed to run transparent mode:                              │
14│                                                                                │
15│   - DLE (10) must precede STX for transparent mode.                            │
16│   - DLE need not precede ETX for transparent mode because microcode inserts    │
17│     DLE.                                                                       │
18│                                                                                │
19│  Enter data in hexadecimal. . . . . . . . ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣┴┤     │
20│                                                                                │
21│ Cmd3-Previous display   Cmd7-End                                               │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2126   «, f1=0x00, start=0x0027, length=0x03, f5=0x00, f6=0x00, f7=0x03, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                              Message Count Entry                               │
03│                                                                                │
04│                                                                                │
05│  XX message selected is - - - - - - - - - - - - - - - - - - - -  ␣␣            │
06│                                                                                │
07│  Enter YY count. (number of times to transmit message)  .  1-99 ␣␣┴┤           │
08│                                                                                │
09│  Continuously loop on the above XX and YY values? . . . . . Y,N ␣┴┤            │
10│                                                                                │
11│                                                                                │
12│                                                                                │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Cmd3-Previous display   Cmd7-End                                               │
18│                                                                                │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2127   «, f1=0x00, start=0x002a, length=0x03, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                                 Switched Line                                  │
03│                                                                                │
04│                                                                                │
05│  This line is switched.  Perform the following steps:                          │
06│   1. Establish the data link.                                                  │
07│   2. Press the Enter key.                                                      │
08│                                                                                │
09│                                                                                │
10│                                                                                │
11│                                                                                │
12│                                                                                │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Cmd3-Return to message selection   Cmd7-End                                    │
18│                                                                                │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2128   «, f1=0x00, start=0x002d, length=0x04, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                                 Switched Line                                  │
03│                                                                                │
04│                                                                                │
05│  This line is switched.  Perform the following steps:                          │
06│   1. Establish the data link.                                                  │
07│   2. Press the Enter key.  DTR will become active.                             │
08│   3. Replace the telephone receiver.                                           │
09│                                                                                │
10│                                                                                │
11│                                                                                │
12│                                                                                │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Cmd3-Return to message selection   Cmd7-End                                    │
18│                                                                                │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2129   «, f1=0x00, start=0x0031, length=0x05, f5=0x00, f6=0x00, f7=0x1c, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                        Autocall Telephone Number Entry                         │
03│                                                                                │
04│                                                                                │
05│  To automatically dial, perform the following steps:                           │
06│   1. Enter only the necessary digits, SEP or EON characters.                   │
07│       Use a ' character to represent a SEP character.                          │
08│       Use a * character to represent an EON character.                         │
09│        Enter the digits and/or characters . . . . . . . . . . .                │
10│         . . . . . . . . . . . . . . . . . . ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣┴┤     │
11│   2. Press the Enter key.                                                      │
12│                                                                                │
13│  To dial by hand, perform the following steps:                                 │
14│   1. Dial the number.                                                          │
15│   2. Press the Enter key.                                                      │
16│                                                                                │
17│                                                                                │
18│ Cmd3-Return to message selection   Cmd7-End   Help-More information            │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2129H  «, f1=0x00, start=0x0036, length=0x07, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                    Help for Autocall Telephone Number Entry                    │
03│                                                                                │
04│                                                                                │
05│  SEP character use:                                                            │
06│   - A SEP character is inserted in a telephone number to separate digits dialed│
07│      to different telephone exchanges.                                         │
08│   - If the SEP trap is not configured, a SEP character causes the autocall unit│
09│      to stop dialing digits until the next telephone exchange signals ready by │
10│      sending a second dial tone.                                               │
11│   - If the SEP trap is configured, a SEP character will cause a 3-second pause │
12│      before the next digit is dialed.                                          │
13│                                                                                │
14│  EON character use:                                                            │
15│   - An EON character is used with an autocall unit that cannot recognize an    │
16│      answer tone signal.                                                       │
17│   - An EON character is placed at the end of a telephone number to indicate to │
18│      the autocall unit that all digits have been dialed.                       │
19│   - If the EON trap is configured the EON will not be used.                    │
20│                                                                                │
21│                                                                                │
22│ Enter-Exit help text   Cmd7-End                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B21210  «, f1=0x00, start=0x003d, length=0x03, f5=0x00, f6=0x00, f7=0x18, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                             X.21 Call Number Entry                             │
03│                                                                                │
04│                                                                                │
05│  X.21 call number . . . . . . . . . . . . . . . ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣┴┤     │
06│                                                                                │
07│   ╳Valid characters are: 0 1 2 3 4 5 6 7 8 9 . - , / *                   ╳     │
08│                                                                                │
09│                                                                                │
10│  ╳ If this line is direct call line then do not key in any numbers and  ╳      │
11│  ╳ press Enter key              ╳                                              │
12│                                                                                │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Cmd3-Return to message selection   Cmd7-End                                    │
18│                                                                                │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B21211  «, f1=0x00, start=0x0040, length=0x03, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                              Requester is Active                               │
03│                                                                                │
04│                                                                                │
05│  XX message selected is - - - - - - - - - - - - - - - - - - - -  ␣␣            │
06│                                                                                │
07│  YY count selected is - - - - - - - - - - - - - - - - - - - - -  ␣␣            │
08│                                                                                │
09│                                                                                │
10│                                                                                │
11│                                                                                │
12│                                                                                │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Cmd7-End   Cmd19-Cancel requester operation                                    │
18│  (May need 33 seconds for Cmd7 or Cmd19 command to complete.)                  │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B21212  «, f1=0x00, start=0x0043, length=0x02, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│  ╳                 Requester Operation Ended With no Errors               ╳    │
03│                                                                                │
04│                                                                                │
05│  XX message selected was  - - - - - - - - - - - - - - - - - - -  ␣␣            │
06│                                                                                │
07│  YY count selected was  - - - - - - - - - - - - - - - - - - - -  ␣␣            │
08│                                                                                │
09│                                                                                │
10│                                                                                │
11│                                                                                │
12│                                                                                │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Enter-Return to message selection   Cmd7-End                                   │
18│                                                                                │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2131   «, f1=0x00, start=0x0045, length=0x02, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                                                                                │
03│                                                                                │
04│                                                                                │
05│                                                                                │
06│                                                                                │
07│                                                                                │
08│                                                                                │
09│                             Responder is active.                               │
10│                                                                                │
11│                                                                                │
12│                                                                                │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Cmd7-End   Cmd19-Cancel responder operation                                    │
18│  (May need 33 seconds for Cmd7 or Cmd19 command to complete.)                  │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2133   «, f1=0x00, start=0x0047, length=0x02, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                                                                                │
03│                                                                                │
04│                                                                                │
05│                                                                                │
06│                                                                                │
07│                                                                                │
08│                                                                                │
09│                     Responder is executing a test request.                     │
10│                                                                                │
11│                                                                                │
12│                                                                                │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Cmd7-End   Cmd19-Cancel responder operation                                    │
18│  (May need 33 seconds for Cmd7 or Cmd19 command to complete.)                  │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2132   «, f1=0x00, start=0x0049, length=0x03, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                              Responder is Active                               │
03│                                                                                │
04│                                                                                │
05│          A response has been generated and no errors were detected.            │
06│                                                                                │
07│                                                                                │
08│  XX message - - - - - - - - - - - - - - - - - - - - - - - - - -  ␣␣            │
09│                                                                                │
10│  YY count - - - - - - - - - - - - - - - - - - - - - - - - - - -  ␣␣            │
11│                                                                                │
12│                                                                                │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Cmd7-End   Cmd19-Cancel responder operation.                                   │
18│  (May need 33 seconds for Cmd7 or Cmd19 command to complete.)                  │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2211   «, f1=0x00, start=0x004c, length=0x03, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                            Line Selected is in Use                             │
03│                                                                                │
04│                                                                                │
05│  Another program is using this line.  The other program must release the line  │
06│  before the online test can use the line.                                      │
07│                                                                                │
08│                                                                                │
09│                                                                                │
10│                                                                                │
11│                                                                                │
12│                                                                                │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Enter-Return to test selection   Cmd7-End                                      │
18│                                                                                │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2212   «, f1=0x00, start=0x004f, length=0x03, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                          Selected Line Not Configured                          │
03│                                                                                │
04│                                                                                │
05│  The communications line selected is not configured.                           │
06│                                                                                │
07│  The line must be configured before the online test can use it.                │
08│                                                                                │
09│                                                                                │
10│                                                                                │
11│                                                                                │
12│                                                                                │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Enter-Return to test selection   Cmd7-End                                      │
18│                                                                                │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2212SD «, f1=0x00, start=0x0052, length=0x02, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│     BSC configuration is not supported on this system.                         │
03│                                                                                │
04│     BSC line must be configured before the on line test can be run.            │
05│                                                                                │
06│                                                                                │
07│                                                                                │
08│                                                                                │
09│                                                                                │
10│                                                                                │
11│                                                                                │
12│                                                                                │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Enter-Return to end test      Cmd7-End                                         │
18│                                                                                │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2213   «, f1=0x00, start=0x0054, length=0x03, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                                Selection Error                                 │
03│                                                                                │
04│                                                                                │
05│  This test does not support the configuration of the line selected.            │
06│                                                                                │
07│                                                                                │
08│                                                                                │
09│                                                                                │
10│                                                                                │
11│                                                                                │
12│                                                                                │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Enter-Return to test selection   Cmd7-End                                      │
18│                                                                                │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2231   «, f1=0x00, start=0x0057, length=0x03, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                                Selection Error                                 │
03│                                                                                │
04│                                                                                │
05│  Multipoint responder is not available on this system.                         │
06│                                                                                │
07│  Change the configuration to point-to-point before attempting the test again.  │
08│                                                                                │
09│                                                                                │
10│                                                                                │
11│                                                                                │
12│                                                                                │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Enter-Return to test selection   Cmd7-End                                      │
18│                                                                                │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2311   «, f1=0x00, start=0x005a, length=0x04, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                          Error On Test Initialization                          │
03│                                                                                │
04│                                                                                │
05│  A CRC/LRC/VRC data check error was detected.  Attempt the test again. If      │
06│  this error has occurred several times, suspect a temporary network problem.   │
07│                                                                                │
08│                                                                                │
09│                                                                                │
10│                                                                                │
11│                                                                                │
12│                                                                                │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Enter-Start test again   Cmd7-End                                              │
18│                                                                                │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2312   «, f1=0x00, start=0x005e, length=0x04, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                          Error On Test Initialization                          │
03│                                                                                │
04│                                                                                │
05│  A transmit adapter check error was detected.   A data underrun has occurred.  │
06│  Attempt the test again.  If this error has occurred several times, suspect a  │
07│  problem with one of the following:                                            │
08│   - Line speed(s) may exceed specifications.                                   │
09│   - Hardware problems exist, run internal diagnostics.                         │
10│                                                                                │
11│                                                                                │
12│                                                                                │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Enter-Start test again   Cmd7-End                                              │
18│                                                                                │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2313   «, f1=0x00, start=0x0062, length=0x04, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                          Error on Test Initialization                          │
03│                                                                                │
04│                                                                                │
05│  A receive adapter check error was detected.   A data overrun has occurred.    │
06│  Attempt the test again.  If this error has occurred several times, suspect    │
07│  a problem with one of the following:                                          │
08│   - Line speed(s) may exceed specifications.                                   │
09│   - Hardware problems exist, run internal diagnostics.                         │
10│                                                                                │
11│                                                                                │
12│                                                                                │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Enter-Start test again   Cmd7-End                                              │
18│                                                                                │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2314   «, f1=0x00, start=0x0066, length=0x04, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                          Error On Test Initialization                          │
03│                                                                                │
04│                                                                                │
05│  An abortive disconnect error was detected.  One of the following is the       │
06│  probable cause:                                                               │
07│   - The remote device disconnected the data link.                              │
08│   - No transmit clock.                                                         │
09│   - CTS did not become active.                                                 │
10│                                                                                │
11│                                                                                │
12│                                                                                │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Enter-Return to test selection   Cmd7-End                                      │
18│                                                                                │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2315   «, f1=0x00, start=0x006a, length=0x04, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                          Error On Test Initialization                          │
03│                                                                                │
04│                                                                                │
05│  A NO DSR error has occurred.  One of the following is the probable cause:     │
06│   - DSR was not active.                                                        │
07│   - No transmit clock.                                                         │
08│   - CTS did not become active.                                                 │
09│                                                                                │
10│                                                                                │
11│                                                                                │
12│                                                                                │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Enter-Return to test selection   Cmd7-End                                      │
18│                                                                                │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2321   «, f1=0x00, start=0x006e, length=0x05, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                          Error On Test Initialization                          │
03│                                                                                │
04│                                                                                │
05│  No ACK was correctly received by the requester after transmitting an ENQ.  The│
06│  test attempted the transmission of the ENQ seven times.   One of the following│
07│  is the probable cause:                                                        │
08│   - The responder was not ready.                                               │
09│   - The responder transmitted something other than an ACK.                     │
10│   - The data link was not established.                                         │
11│   - The data link is failing to transfer the ENQ or ACK.                       │
12│                                                                                │
13│  Determine and correct the problem before attempting the test again.           │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Enter-Return to message selection   Cmd7-End                                   │
18│                                                                                │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2322   «, f1=0x00, start=0x0073, length=0x05, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                          Error On Test Initialization                          │
03│                                                                                │
04│                                                                                │
05│  The responder failed to acknowledge the request for test message with an ACK. │
06│  Attempt the test again.  One of the following is the probable cause:          │
07│   - The responder did not correctly receive the request for test message.      │
08│   - The responder did not transmit within 3 seconds after the request for      │
09│     test message was transmitted.                                              │
10│   - The responder transmitted something other than an ACK.                     │
11│   - The data link failed to transfer the request for test message or the ACK.  │
12│   - Check for proper CTS delay.                                                │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Enter-Return to message selection   Cmd7-End                                   │
18│                                                                                │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2323   «, f1=0x00, start=0x0078, length=0x05, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                          Error On test Initialization                          │
03│                                                                                │
04│                                                                                │
05│  The responder failed to answer with an ENQ to the EOT transmitted by the      │
06│  requester.   Attempt the test again.   If the error has occurred several      │
07│  times, suspect a problem with one of the following:                           │
08│   - The responder did not correctly receive the EOT.                           │
09│   - The responder did not transmit within 3 seconds after the EOT was          │
10│     transmitted.                                                               │
11│   - The responder transmitted something other than an ENQ.                     │
12│   - The data link failed to transfer either the EOT or ENQ.                    │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Enter-Return to message selection   Cmd7-End                                   │
18│                                                                                │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2324   «, f1=0x00, start=0x007d, length=0x04, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                          Error On Test Initialization                          │
03│                                                                                │
04│                                                                                │
05│  An ASCII character that was not valid was detected.  The probable cause is    │
06│  invalid ASCII data entered for either test messages 00 or 01.                 │
07│                                                                                │
08│                                                                                │
09│  Enter only valid ASCII data for test message 00 or 01.  Refer to the ASCII    │
10│  conversion chart in the general MIM.                                          │
11│                                                                                │
12│                                                                                │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Enter-Return to message selection   Cmd7-End                                   │
18│                                                                                │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2331   «, f1=0x00, start=0x0081, length=0x03, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                       Request For Test Message Not Valid                       │
03│                                                                                │
04│                                                                                │
05│  Either the XX message or the YY count transmitted by the requester was not    │
06│  valid.                                                                        │
07│                                                                                │
08│    XX message requested - - - - - - - - - - - - - - - - - - - -  ␣␣            │
09│                                                                                │
10│    YY count requested - - - - - - - - - - - - - - - - - - - - -  ␣␣            │
11│                                                                                │
12│  XX or YY count must be corrected by the requester.                            │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Enter-Start test again   Cmd7-End                                              │
18│                                                                                │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2332   «, f1=0x00, start=0x0084, length=0x05, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                          Error On Test Initialization                          │
03│                                                                                │
04│                                                                                │
05│  The requester failed to answer an ACK0 with a request for test message.       │
06│  Attempt the test again.  One of the following is the probable cause:          │
07│   - The requester did not correctly receive the ACK0.                          │
08│   - The requester did not transmit within 3 seconds after the ACK0 was         │
09│     transmitted.                                                               │
10│   - The requester transmitted something other than the request for test        │
11│     message.                                                                   │
12│   - The data link failed to transfer the ACK0 or the request for test          │
13│     message.                                                                   │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Enter-Start test again   Cmd7-End                                              │
18│                                                                                │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2333   «, f1=0x00, start=0x0089, length=0x04, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                          Error On Test Initialization                          │
03│                                                                                │
04│                                                                                │
05│  The requester failed to answer an ACK1 with an EOT.  Attempt the test again.  │
06│  One of the following is the probable cause:                                   │
07│   - The requester did not correctly receive the ACK1.                          │
08│   - The requester did not transmit within 3 seconds after the ACK1 was         │
09│     transmitted.                                                               │
10│   - The requester transmitted something other than an EOT.                     │
11│   - The data link failed to transfer the ACK1 or the EOT.                      │
12│                                                                                │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Enter-Start test again   Cmd7-End                                              │
18│                                                                                │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2334   «, f1=0x00, start=0x008d, length=0x05, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                          Error On Test Initialization                          │
03│                                                                                │
04│                                                                                │
05│  No ACK was correctly received by the responder after transmitting an ENQ.     │
06│  The test attempted the transmission of the ENQ seven times.   One of the      │
07│  following is the probable cause:                                              │
08│   - The data link was lost.                                                    │
09│   - The requester transmitted something other than an ACK.                     │
10│   - The data link is failing to transfer the ENQ or the ACK.                   │
11│                                                                                │
12│  Determine and correct the problem before attempting the test again.           │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Enter-Start test again   Cmd7-End                                              │
18│                                                                                │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2411   «, f1=0x00, start=0x0092, length=0x04, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                       Permanent Error Detected in Test Mode                    │
03│                                                                                │
04│                                                                                │
05│  An abortive disconnect error was detected.  One of the following is the       │
06│  probable cause:                                                               │
07│   - The remote device disconnected the data link.                              │
08│   - No transmit clock.                                                         │
09│   - CTS did not become active.                                                 │
10│                                                                                │
11│                                                                                │
12│                                                                                │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Enter-Return to test selection   Cmd7-End                                      │
18│                                                                                │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2412   «, f1=0x00, start=0x0096, length=0x03, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                     Permanent Error Detected in Test Mode                      │
03│                                                                                │
04│                                                                                │
05│  A NO DSR error has occurred.  One of the following is the probable cause:     │
06│   - DSR was not active.                                                        │
07│   - No transmit clock.                                                         │
08│   - CTS did not become active.                                                 │
09│                                                                                │
10│                                                                                │
11│                                                                                │
12│                                                                                │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Enter-Return to test selection   Cmd7-End                                      │
18│                                                                                │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2413   «, f1=0x00, start=0x0099, length=0x03, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                          Error Detected in Test Mode                           │
03│                                                                                │
04│                                                                                │
05│  The remote device has a problem and is not able to receive the test message   │
06│  transmitted by this device. 25 WACKS have been received.                      │
07│                                                                                │
08│  Determine and fix the remote device's problem before attempting the test      │
09│  again.                                                                        │
10│                                                                                │
11│                                                                                │
12│                                                                                │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Enter-Start test again   Cmd7-End                                              │
18│                                                                                │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2414   «, f1=0x00, start=0x009c, length=0x03, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                     Permanent Error Detected in Test Mode                      │
03│                                                                                │
04│                                                                                │
05│  The remote device has not transmitted a test message in 21 seconds.  One of   │
06│  the following is the probable cause:                                          │
07│   - The remote device operation has stopped.                                   │
08│   - The data link is failing to transfer the test message or the ACK.          │
09│                                                                                │
10│                                                                                │
11│                                                                                │
12│                                                                                │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Enter-Start test again   Cmd7-End                                              │
18│                                                                                │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2421   «, f1=0x00, start=0x009f, length=0x08, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                 Message Error                                  │
02│  The message received was not the message requested.  Data received is         │
03│  displayed in reverse image, data requested is not reverse imaged.             │
04│                                                                                │
05│  ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣  │
06│ ╳␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣╳ │
07│  ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣  │
08│ ╳␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣╳ │
09│  ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣  │
10│ ╳␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣╳ │
11│  ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣  │
12│ ╳␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣╳ │
13│  ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣  │
14│ ╳␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣╳ │
15│  ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣  │
16│ ╳␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣╳ │
17│  ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣  │
18│ ╳␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣╳ │
19│  ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣  │
20│ ╳␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣╳ │
21│                                                                                │
22│ Enter-Return to message selection   Cmd7-End                                   │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2422   «, f1=0x00, start=0x00a7, length=0x04, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                     Temporary Errors Detected in Test Mode                     │
03│                                                                                │
04│                                                                                │
05│  Message requested (XX value) - - - - - - - - - - - - - - - - -  ␣␣            │
06│                                                                                │
07│  Message count requested (YY value) - - - - - - - - - - - - - -  ␣␣            │
08│                                                                                │
09│  Valid messages actually received - - - - - - - - - - - - - - -  ␣␣␣           │
10│                                                                                │
11│  CRC/LRC/VRC errors detected  - - - - - - - - - - - - - - - - -  ␣␣␣           │
12│                                                                                │
13│  Transmit adapter checks detected - - - - - - - - - - - - - - -  ␣␣␣           │
14│                                                                                │
15│  Receive adapter checks detected  - - - - - - - - - - - - - - -  ␣␣␣           │
16│                                                                                │
17│                                                                                │
18│ Enter-Start test again   Cmd5-Display data received on last CRC/LRC/VRC error  │
19│ Cmd7-End                 Cmd19-Cancel requester operation                      │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2423   «, f1=0x00, start=0x00ab, length=0x08, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                   Data Error                                   │
02│  The data received had a CRC/LRC/VRC data error.  Data received is displayed   │
03│  in reverse image, data requested is not reverse imaged.  If the program was   │
04│  looping on XX and YY values, looping has been stopped.                        │
05│  ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣  │
06│ ╳␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣╳ │
07│  ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣  │
08│ ╳␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣╳ │
09│  ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣  │
10│ ╳␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣╳ │
11│  ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣  │
12│ ╳␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣╳ │
13│  ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣  │
14│ ╳␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣╳ │
15│  ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣  │
16│ ╳␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣╳ │
17│  ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣  │
18│ ╳␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣╳ │
19│  ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣  │
20│ ╳␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣╳ │
21│                                                                                │
22│ Enter-Start test again   Cmd7-End                                              │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2424   «, f1=0x00, start=0x00b3, length=0x02, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                                                                                │
03│                                                                                │
04│                                                                                │
05│                                                                                │
06│                                                                                │
07│                                                                                │
08│                                                                                │
09│                   No CRC/LRC/VRC data checks have occurred.                    │
10│                                                                                │
11│                                                                                │
12│                                                                                │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Enter-Continue   Cmd7-End                                                      │
18│                                                                                │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2431   «, f1=0x00, start=0x00b5, length=0x05, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                               Response Complete                                │
03│                                                                                │
04│            A response has been generated and errors were detected.             │
05│                                                                                │
06│  Responder is active.                                                          │
07│                                                                                │
08│  XX message - - - - - - - - - - - - - - - - - - - - - - - - - -  ␣␣            │
09│  YY count - - - - - - - - - - - - - - - - - - - - - - - - - - -  ␣␣            │
10│  Receive time-outs detected - - - - - - - - - - - - - - - - - -  ␣␣            │
11│  CRC/LRC/VRC errors detected  - - - - - - - - - - - - - - - - -  ␣␣            │
12│  Transmit adapter checks detected - - - - - - - - - - - - - - -  ␣␣            │
13│  Receive adapter checks detected  - - - - - - - - - - - - - - -  ␣␣            │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Cmd7-End  Cmd19-Cancel responder operation                                     │
18│  (May need 33 seconds for Cmd7 or Cmd19 command to complete.)                  │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2511   «, f1=0x00, start=0x00ba, length=0x04, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                               X.21 Dial-up Error                               │
03│                                                                                │
04│                    A call progress signal error occurred.                      │
05│                                                                                │
06│                                                                                │
07│  The network canceled the data link by sending a negative call progress signal.│
08│                                                                                │
09│  The call progress signal                                                      │
10│  was  - - - - - - - - - - - - -  ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣      │
11│                                                                                │
12│  Perform the correction that is suitable for the call progress signal.         │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Enter-Return to call-number entry   Cmd3-Return to message selection           │
18│ Cmd7-End                                                                       │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2512   «, f1=0x00, start=0x00be, length=0x03, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                               BSC ONLINE TEST                                ␣␣│
01│                                                                                │
02│                              X.21 Dial-up Error                                │
03│                                                                                │
04│                         A T1 time-out error occurred.                          │
05│                                                                                │
06│                                                                                │
07│                                                                                │
08│  The network did not respond to the call request.                              │
09│                                                                                │
10│  Attempt the dial-up again.                                                    │
11│                                                                                │
12│                                                                                │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Enter-Return to call-number entry   Cmd3-Return to message selection           │
18│ Cmd7-End                                                                       │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2513   «, f1=0x00, start=0x00c1, length=0x03, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                               X.21 Dial-up Error                               │
03│                                                                                │
04│                         A T2 time-out error occurred.                          │
05│                                                                                │
06│                                                                                │
07│                                                                                │
08│  The network did not respond to the selection signal.                          │
09│                                                                                │
10│  Attempt the dial-up again.                                                    │
11│                                                                                │
12│                                                                                │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Enter-Return to call-number entry   Cmd3-Return to message selection           │
18│ Cmd7-End                                                                       │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2514   «, f1=0x00, start=0x00c4, length=0x03, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                               X.21 Dial-up Error                               │
03│                                                                                │
04│                         A T3A time-out error occurred.                         │
05│                                                                                │
06│                                                                                │
07│  The network responded to the selection signal with information provided by    │
08│  the DCE, but did not signal ready for data.                                   │
09│                                                                                │
10│  Attempt the dial-up again.                                                    │
11│                                                                                │
12│                                                                                │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Enter-Return to call-number entry   Cmd3-Return to message selection           │
18│ Cmd7-End                                                                       │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2515   «, f1=0x00, start=0x00c7, length=0x03, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                               X.21 Dial-up Error                               │
03│                                                                                │
04│                         A T3B time-out error occurred.                         │
05│                                                                                │
06│                                                                                │
07│  The network responded with a group 0 call progress signal, but did not signal │
08│  ready for data.                                                               │
09│                                                                                │
10│  The call progress signal                                                      │
11│  was  - - - - - - - - - - - - -  ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣      │
12│                                                                                │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Enter-Return to call-number entry   Cmd3-Return to message selection           │
18│ Cmd7-End                                                                       │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2516   «, f1=0x00, start=0x00ca, length=0x03, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                               X.21 Dial-up Error                               │
03│                                                                                │
04│                            A parity error occurred.                            │
05│                                                                                │
06│                                                                                │
07│  The attempt to establish a data link failed because a parity error was        │
08│  detected on an incoming character.                                            │
09│                                                                                │
10│  Attempt the dial-up again.                                                    │
11│                                                                                │
12│                                                                                │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Enter-Return to call-number entry   Cmd3-Return to message selection           │
18│ Cmd7-End                                                                       │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2517   «, f1=0x00, start=0x00cd, length=0x03, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                               X.21 Dial-up Error                               │
03│                                                                                │
04│                          A DCE clear error occurred.                           │
05│                                                                                │
06│                                                                                │
07│  The network canceled the dial-up by performing a DCE clear.                   │
08│                                                                                │
09│  Attempt the dial-up again.                                                    │
10│                                                                                │
11│                                                                                │
12│                                                                                │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Enter-Return to call-number entry  Cmd3-Return to message selection            │
18│ Cmd7-End                                                                       │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2518   «, f1=0x00, start=0x00d0, length=0x04, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                               X.21 Dial-up Error                               │
03│                                                                                │
04│                        A DCE not ready error occurred.                         │
05│                                                                                │
06│                                                                                │
07│  The data link was not established because the DCE was not ready.              │
08│                                                                                │
09│  Ensure that the DCE is powered up and connected to the system before          │
10│  attempting the dial-up again.                                                 │
11│                                                                                │
12│                                                                                │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Enter-Return to call-number entry   Cmd3-Return to message selection           │
18│ Cmd7-End                                                                       │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2519   «, f1=0x00, start=0x00d4, length=0x03, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                               X.21 Dial-up Error      .                        │
03│                                                                                │
04│                       An adapter check error occurred.                         │
05│                                                                                │
06│                                                                                │
07│  An underrun or overrun occurred while the dial-up was in progress.            │
08│                                                                                │
09│  Attempt the dial-up again.                                                    │
10│                                                                                │
11│                                                                                │
12│                                                                                │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Enter-Return to call-number entry   Cmd3-Return to message selection           │
18│ Cmd7-End                                                                       │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2611   «, f1=0x00, start=0x00d7, length=0x03, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                                 Autocall Error                                 │
03│                                                                                │
04│                 An error occurred while automatically dialing.                 │
05│                                                                                │
06│                                                                                │
07│  The error was a ␣␣␣ error and was ␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣␣                     │
08│                                                                                │
09│                                                                                │
10│                                                                                │
11│                                                                                │
12│                                                                                │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Enter-Return to telephone number entry   Cmd3-Return to message selection      │
18│ Cmd7-End                                                                       │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2214   «, f1=0x00, start=0x00da, length=0x02, f5=0x00, f6=0x00, f7=0x00, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                      Not enough Communication controller storage.              │
03│                                                                                │
04│                                                                                │
05│  An X.21 switched line requires a minimum of 32K words of Communication        │
06│  controller storage.                                                           │
07│                                                                                │
08│                                                                                │
09│                                                                                │
10│                                                                                │
11│                                                                                │
12│                                                                                │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│ Enter-Return to test selection   Cmd7-End                                      │
18│                                                                                │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»SLOTMSG «, f1=0x00, start=0x00dc, length=0x02, f5=0x00, f6=0x00, f7=0x05, f8=0x00, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                ╳   BSCTEST   ╳                                 │
01│                                                                                │
02│                          ╳     BSC online test       ╳                         │
03│                                                                                │
04│                                                                                │
05│ ╳Location of DIAG23 or DIAG43 or DSKT03 or DSKT11 or DSKT61                    │
06│   diskette  . . . . . . . . . . . . . . .  S1,S2,S3,M1.nn,M2.nn S1   ┴┤        │
07│                                                                                │
08│                                                                                │
09│                                                                                │
10│                                                                                │
11│                                                                                │
12│                                                                                │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│                                                                                │
18│                                                                                │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘
FormPointer36 {name=»B2129C  «, f1=0x00, start=0x00de, length=0x01, f5=0x00, f6=0x00, f7=0x00, f8=0x80, f9=0000000000000000}
  ┌────────────────────────────────────────────────────────────────────────────────┐
00│                                BSC ONLINE TEST                               ␣␣│
01│                                                                                │
02│                                                                                │
03│                                                                                │
04│                                                                                │
05│                                                                                │
06│                                                                                │
07│                                                                                │
08│                                                                                │
09│                                                                                │
10│                                                                                │
11│                 ╳         The dial-up is proceeding.       ╳                   │
12│                                                                                │
13│                                                                                │
14│                                                                                │
15│                                                                                │
16│                                                                                │
17│                                                                                │
18│                                                                                │
19│                                                                                │
20│                                                                                │
21│                                                                                │
22│                                                                                │
23│                                                                                │
24│                                                                                │
25│                                                                                │
26│                                                                                │
27│                                                                                │
  └────────────────────────────────────────────────────────────────────────────────┘

Full view