DataMuseum.dk

Presents historical artifacts from the history of:

IBM System/3

This is an automatic "excavation" of a thematic subset of
artifacts from Datamuseum.dk's BitArchive.

See our Wiki for more about IBM System/3

Excavated with: AutoArchaeologist - Free & Open Source Software.


top - metrics - download

⟦c905e3172⟧ s3xseg

    Length: 5842 (0x16d2)
    Types: s3xseg
    Names: »S$E000«

Derivation

└─⟦d0bc1a931⟧ Bits:30009189 5704-sc1.V08.ccp
    └─⟦64693a1c9⟧ 
        └─⟦this⟧ »S$E000« 

TextSegment

       MACRO                                                            00010000                
.********************************************************************** 00020000                
.*                                                                    * 00030000                
.* NAME: $E000                                                        * 00040000                
.*                                                                    * 00050000                
.* MODIFICATION LEVEL: VERSION 3, MODIFICATION LEVEL 0 MODEL 15       * 00060000                
.*                                                                    * 00070000                
.* FUNCTION:                                                          * 00080000                
.*                                                                    * 00090000                
.*   . CCP GENERATION SECOND PASS MACRO-INSTRUCTION -- SET SYSTEM     * 00100000                
.*     GLOBAL VARIABLES                                               * 00110000                
.*                                                                    * 00120000                
.* INPUT OPERANDS:                                                    * 00130000                
.*                                                                    * 00140000                
.*   . #M-0/1/2/3/4/5/6/7/8                                           * 00150000                
.*                                                                    * 00160000                
.*   . NUMBER OF MLTA LINES SUPPORTED                                 * 00170000                
.*                                                                    * 00180000                
.*   . #B-0/1/2                                                       * 00190000                
.*                                                                    * 00200000                
.*     NUMBER OF BSC ADAPTERS SUPPORTED                               * 00210000                
.*                                                                    * 00220000                
.*   . DF-0/1                                                         * 00230000                
.*                                                                    * 00240000                
.*     1=DISPLAY FORMAT FACILITY SUPPORTED / 0=NOT SUPPORTED          * 00250000                
.*                                                                    * 00260000                
.*   . DE-0/1                                                         * 00270000                
.*                                                                    * 00280000                
.*     1=DATA MODE ESCAPE SUPPORTED / 0=NOT SUPPORTED                 * 00290000                
.*                                                                    * 00300000                
.*   . MS-0/1                                                         * 00310000                
.*                                                                    * 00320000                
.*     1=MINIMUM CORE SYSTEM SUPPORT / 0=NOT MINIMUM CORE SUPPORT     * 00330000                
.*                                                                    * 00340000                
.*   . RF-0/1                                                         * 00350000                
.*                                                                    * 00360000                
.*     1=READ UNDER FORMAT FACILITY SUPPORTED / 0= NOT SUPPORTED.     * 00370000                
.*                                                                    * 00380000                
.*   . RS-0/1                                                           00390000                
.*                                                                      00400000                
.*     1=RESIDENT ACCEPT INPUT FACILITY SUPPORTED / 0=NOT SUPPORTED     00410000                
.*                                                                      00420000                
.********************************************************************** 00430000                
       $E000 &#M-,&#B-,&DF-,&MS-,&DE-,&RF-,&RS-                         00440000                
.*                                                                      00450000                
.*---------  SYSTEM GLOBAL VARIABLES  --------------------------------* 00460000                
.*                                                                      00470000                
       GBLA  &MLA,&BSC                 . # OF TP LINES.                 00480000                
.*                                                                      00490000                
       GBLB  &MLTA                     . MLTA SUPPORT:                  00500000                
.*                                     .   1=SUPPORTED / 0=NOT          00510000                
.*                                                                      00520000                
       GBLB  &NOM                      . INVERSE OF &MLTA               00530000                
.*                                                                      00540000                
       GBLB  &BSCA                     . BSCA SUPPORT:                  00550000                
.*                                     .   1=SUPPORTED / 0=NOT          00560000                
.*                                                                      00570000                
       GBLB  &NOB                      . INVERSE OF &BSCA               00580000                
.*                                                                      00590000                
       GBLB  &ONE                      . SUPPORT OF SINGLE ADAPTER TYPE 00600000                
.*                                     .   1=MLTA *OR* BSCA / 0=BOTH    00610000                
.*                                                                      00620000                
       GBLB  &DME                      . DATA MODE ESCAPE SUPPORT:      00630000                
.*                                     .   1=SUPPORTED / 0=NOT          00640000                
.*                                                                      00650000                
       GBLB  &NDME                     . INVERSE OF &DME                00660000                
.*                                                                      00670000                
       GBLB  &DFF                      . DISPLAY FORMAT FACILITY:       00680000                
.*                                     .   1=SUPPORTED / 0=NOT          00690000                
.*                                                                      00700000                
       GBLB  &NDF                      . INVERSE OF &DFF                00710000                
.*                                                                      00720000                
       GBLB  &RUF                      . READ UNDER FORMAT FACILITY:    00730000                
.*                                     .   1=SUPPORTED / 0=NOT          00740000                
.*                                                                      00750000                
       GBLB  &NRUF                     . INVERSE OF &RUF                00760000                
.*                                                                      00770000                
       GBLB  &RAI                      . RESIDENT ACCEPT INPUT FACILITY 00780000                
.*                                     .   1=SUPPORTED / 0=NOT          00790000                
       GBLB  &NRAI                     . INVERSE OF &RAI                00800000                
.*                                                                      00810000                
.*                                                                      00820000                
       GBLB  &MIN                      . SUPPORT OF MINIMUM-CORE SYSTEM 00830000                
.*                                     .   1=MINIMUM CORE / 0=NOT       00840000                
.*                                                                      00850000                
       TEXT                                                             00860000                
.*                                                                      00870000                
.*---------  SET FOR SUPPORT OF MLTA ADAPTER AND DEVICES                00880000                
.*                                                                      00890000                
       AIF   (&#M EQ '0').#M0          . SKIP IF *NO* MLTA              00900000                
.*                                                                      00910000                
&MLTA  SETB  1                         . MLTA SUPPORT                   00920000                
&MLA   SETA  &#M                       . # OF MLTA LINES                00930000                
       AGO   .#MEND                                                     00940000                
.*                                                                      00950000                
.#M0   ANOP                            . *NO* MLTA SUPPORT              00960000                
&NOM   SETB  1                                                          00970000                
.*                                                                      00980000                
.#MEND ANOP                            . END OPERAND '#M'               00990000                
.*                                                                      01000000                
.*---------  SET FOR SUPPORT OF BSCA ADAPTER AND DEVICES  ------------* 01010000                
.*                                                                      01020000                
       AIF   (&#B EQ '0').#B0          . SKIP IF *NO* BSCA SUPPORT      01030000                
.*                                                                      01040000                
&BSCA  SETB  1                         . BSCA SUPPORT                   01050000                
&BSC   SETA  &#B                       . # OF BSCA LINES                01060000                
       AGO   .#BEND                                                     01070000                
.*                                                                      01080000                
.#B0   ANOP                            . *NO* BSCA SUPPORT              01090000                
&NOB   SETB  1                                                          01100000                
.*                                                                      01110000                
.#BEND ANOP                            . END OPERAND '#B'               01120000                
.*                                                                      01130000                
.*---------  SET FOR COMBINATION OF COMMUNICATIONS SUPPORT  ----------* 01140000                
.*                                                                      01150000                
       AIF   (&BSCA NE '1').ONE        . SKIP IF NO BSCA SUPPORT        01160000                
       AIF   (&MLTA).ONEND             . SKIP IF MLTA SUPPORT           01170000                
.*                                                                      01180000                
.ONE   ANOP                            . ONLY MLTA *OR* ONLY BSCA       01190000                
&ONE   SETB  1                                                          01200000                
.*                                                                      01210000                
.ONEND ANOP                            . END COMBINATION EVALUATION     01220000                
.*                                                                      01230000                
.*---------  SET FOR DATA MODE ESCAPE  -------------------------------* 01240000                
.*                                                                      01250000                
       AIF   (&DE EQ '0').DE0          . SKIP IF *NO* DATA MODE ESCAPE  01260000                
.*                                                                      01270000                
&DME   SETB  1                         . SET FOR DME SUPPORT            01280000                
       AGO   .DEEND                                                     01290000                
.*                                                                      01300000                
.DE0   ANOP                            . *NO* DATA MODE ESCAPE          01310000                
&NDME  SETB  1                         . SET *NO* DME SUPPORT           01320000                
.*                                                                      01330000                
.DEEND ANOP                            . END OPERAND 'DE'               01340000                
.*                                                                      01350000                
.*---------  SET FOR SUPPORT OF DISPLAY FORMAT FACILITY  -------------* 01360000                
.*                                                                      01370000                
       AIF   (&DF EQ '0').DF0          . SKIP IF *NO* DFF SUPPORT       01380000                
.*                                                                      01390000                
&DFF   SETB  1                         . DFF SUPPORT                    01400000                
       AGO   .DFEND                                                     01410000                
.*                                                                      01420000                
.DF0   ANOP                            . *NO* DFF SUPPORT               01430000                
&NDF   SETB  1                                                          01440000                
.*                                                                      01450000                
.DFEND ANOP                            . END OPERAND 'DF'               01460000                
.*                                                                      01470000                
.*---------  SET FOR SUPPORT OF READ UNDER FORMAT FACILITY  ----------* 01480000                
.*                                                                      01490000                
       AIF   (&RF EQ '0').RF0          . SKIP IF *NO* RUF SUPPORT       01500000                
.*                                                                      01510000                
&RUF   SETB  1                         . RUF SUPPORT                    01520000                
       AGO   .RFEND                                                     01530000                
.*                                                                      01540000                
.RF0   ANOP                            . *NO* RUF SUPPORT               01550000                
&NRUF  SETB  1                                                          01560000                
.*                                                                      01570000                
.RFEND ANOP                            . END OPERAND 'RUF'              01580000                
.*                                                                      01590000                
.*-----------SET FOR SUPPORT OF RESIDENT ACCEPT INPUT  ---------------* 01600000                
.*                                                                      01610000                
       AIF   (&RS EQ '0').RS0          . SKIP IF *NO* ACCEPT SUPPORT    01620000                
.*                                                                      01630000                
&RAI   SETB  1                         . 'ACCEPT' SUPPORT               01640000                
       AGO   .RSEND                                                     01650000                
.*                                                                      01660000                
.RS0   ANOP                            . *NO* ACCEPT SUPPORT            01670000                
&NRAI  SETB  1                                                          01680000                
.*                                                                      01690000                
.RSEND ANOP                            . END OPERAND 'ACCEPT'           01700000                
.*                                                                      01710000                
.*---------  SET FOR SUPPORT OF MINIMUM CORE SYSTEM  -----------------* 01720000                
.*                                                                      01730000                
       AIF   (&MS EQ '0').MSEND        . SKIP IF *NOT* MINIMUM CORE     01740000                
.*                                                                      01750000                
&MIN   SETB  1                         . MINIMUM CORE SYSTEM            01760000                
.*                                                                      01770000                
.MSEND ANOP                            . END OPERAND 'MS'               01780000                
.*                                                                      01790000                
.*---------  END SYSTEM VARIABLE SET MACRO  --------------------------* 01800000                
.*                                                                      01810000                
*  PTF LOG NO.-214,LEVEL-04,NAME-$E085                                                          
*  PTF LOG NO.-214,LEVEL-04,NAME-$E093                                                          
       MEND                                                             01820000