DataMuseum.dkPresents historical artifacts from the history of: Rational R1000/400 |
This is an automatic "excavation" of a thematic subset of
See our Wiki for more about Rational R1000/400 Excavated with: AutoArchaeologist - Free & Open Source Software. |
top - metrics - download
Length: 4008 (0xfa8)
Types: TextFile
Notes: R1k Text-file segment
└─⟦8527c1e9b⟧ Bits:30000544 8mm tape, Rational 1000, Arrival backup of disks in PAM's R1000
└─⟦cfc2e13cd⟧ »Space Info Vol 2«
└─⟦0335a5cbb⟧
└─⟦this⟧
Date : December 15, 1992 at 3:48:42 PM
Customer : ***
Machine : Ancolie (IRP Mulhouse) [408459]
Period : 16-SEP-92 to 15-DEC-92
RATIONAL
PREVENTIVE MAINTENANCE CHECKLIST
(1) Overall System Health Check ___
Ensure customer has a current FULL backup ___
Review system error logs summary ___
Run 5 minutes disk exerciser ___
Run 1 pass tape exerciser ___
Run Level 2 FRU diagnostics ___
Check +5v DC at R1000 backplane _____v _____v _____v ___
Check 15v DC _______v _______v (Series 200) ___
(2) General System Cleanliness ___
Check/clean main cabinet filters ___
Check/clean disk filters ___
Clean cabinets and tape drive surfaces ___
Clean inside and top of R1000 cabinets where necessary ___
Check all fans for proper operation ___
PM line printer ___
Page Counter _________pages ___
Check/replace ribbon ___
Clean ribbon rollers ___
Clean print band ___
Check for character alignment and print quality ___
Vacuum ribbon lint and paper dust ___
PM tape drive
Clean R/W head, tape cleaner, and tape path ___
Clean filters on IOP (Series 100) ___
Clean operations terminals ___
(3) Post PM System Diagnostics ___
Run foreplane test ___
Run full pass of R1000 processor diagnostics ___
Run functional diagnostics ___
Run 01 test on tape drive with full (2400 ft.) tape ___
Run 5 minutes disk exerciser ___
Run 1 minute tape exerciser ___
Run communications test on at least 1 port per 8-port module ___
(4) Complete SAR ---
\f
Booted Configuration : D_12_6_5
Machine Id = 408459
R1000 Series 400 System
Board Part# Serial# Art Rev ECO Level Build Date
---------------------- ------- ---------- -------- ---------- -------------
Sequencer 45 4800 2 4 91/06/19
Field Isolation Unit 44 4818 2 2 91/07/15
IOC 49 4774 3 11 91/07/12
Type 43 4865 2 2 91/08/07
Value 42 4260 1 1 91/02/25
32 MB Memory 47 5038 2 4 91/08/19
ReshA 41 4879 3 13 91/08/19
CMC controller serial number = 774
System Boot Configuration Settings
==================================
Maintainance_Mode => False
Kernel_Debugger_Auto_Boot => True
Kernel_Debugger_Wait_On_Crash => True
Kernel_Debugger_Dialout_On_Crash => True
Modem_Can_Dialout => False
Modem_Can_Answer => False
Eedb_Auto_Boot => True
Kernel_Auto_Boot => True
DISK BAD BLOCK INFORMATION
Vol Manufact Retarget Total HDA
===========================================
1 185 0 185 J7496
2 136 0 136 J7500