4        T̲E̲S̲T̲ ̲P̲R̲O̲C̲E̲D̲U̲R̲E̲


         Since the equipment is used as PC S/W Test System,
         it is assumed that an operational condition excists
         (Development System booted). Close down the PC S/W
         Test Sstem.

         The H/W, now being PC LTU ̲TEST System, are operated
         from the PC maintenance-VDU.

4.1      S̲t̲a̲r̲t̲ ̲T̲e̲s̲t̲

         To operate the LTU-test apply the following commands:

             OPEN 
             N
             LOGIN SYS PCTEST
             :OC ̲SPEED
             :SET ̲TIME
             YY MM DD HH MM SS
             :LTUDRV.C         TO:S
             LOGIN SYS1 PCTEST
             :LTUTST.C
             --)BOOTLOAD
             --)OPEN
             --)LTUTEST

         The program responds with :

             LTU TEST STARTED (-TIME-)

         and data running on the LTU-VDU, showing that the test
         is on 



4.2      S̲t̲o̲p̲ ̲T̲e̲s̲t̲

         To terminate the test simply p