DataMuseum.dk

Presents historical artifacts from the history of:

Rational R1000/400

This is an automatic "excavation" of a thematic subset of
artifacts from Datamuseum.dk's BitArchive.

See our Wiki for more about Rational R1000/400

Excavated with: AutoArchaeologist - Free & Open Source Software.


top - download

⟦1549a20d3⟧

    Length: 4096 (0x1000)
    Notes: 00_class, 5800_R1K_CODE, 74_tag, NULL, R1k_Segment, seg_ccb0b3

Derivation

└─⟦8527c1e9b⟧ Bits:30000544 8mm tape, Rational 1000, Arrival backup of disks in PAM's R1000
    └─ ⟦cfc2e13cd⟧ »Space Info Vol 2« 
        └─⟦this⟧ 

Disassembly

0000 000f       |    |		.CONST	0x000f								; Version of machine code
0001 5800       |X   |		.CONST	0x5800								; Diana Version, RCG Major Version, RCG minor version
0002 0000       |    |		.CONST	0x0000								; Zero
0003 0620       |    |		.CONST	0x0620								; Offset of debug table
0004 0100       |    |		.CONST	0x0100								; Default exception handler - raise instruction
0005 00bb       |    |		.CONST	0x00bb								; Module termination instruction - signal completion
0006 0000       |    |		.CONST	0x0000								; Offset to segment table (only in elab segments)
0007 8003       |    |		.CONST	0x8003								; 0, wired, #pages in seg - 1)
0008 ; --------------------------------------------------------------------------------------
0008 ; SUBPROGRAM
0008 ; --------------------------------------------------------------------------------------
0008 0049       | I  |		.CONST	0x0049								; Address of begin
0009 0004       |    |		.CONST	0x0004								; Address of exception handler
000a 001f       |    |		.CONST	0x001f								; Number of locals
000b			INIT_0008:
000b 0092 004b  |   K|		Action	Push_String_Extended,0x4b					; "If this switch is set to True, the RCI will automatically create the remote directory when you call a CMVC command to create an RCI view. Otherwise no remote directory will be created by a CMVC command. The default value is True."
000d 0129       | )  |		Execute	Any,Make_Visible
000e 0092 004c  |   L|		Action	Push_String_Extended,0x4c					; "If this switch is set to True, the RCI will automatically transfer units during the Installed-to-Coded phase in Batch mode. If this switch is False, units will only be transferred during a Build_Script operation if the Transfer_To_Target parameter is set to True. The default value is False."
0010 0129       | )  |		Execute	Any,Make_Visible
0011 0092 004d  |   M|		Action	Push_String_Extended,0x4d					; "This switch contains a string that will be appended to the unit name in the generated target compiler command."
0013 0129       | )  |		Execute	Any,Make_Visible
0014 0092 004e  |   N|		Action	Push_String_Extended,0x4e					; "This switch contains a string that will be inserted before the unit name in the generated target compiler command."
0016 0129       | )  |		Execute	Any,Make_Visible
0017 0092 004f  |   O|		Action	Push_String_Extended,0x4f					; "This switch applies to all views of target-key "
0019 0129       | )  |		Execute	Any,Make_Visible
001a 0092 0050  |   P|		Action	Push_String_Extended,0x50					; " that are created within libraries which are associated with this switch-file. Views created under these conditions will have their corresponding remote directories built on the machine named by this switch value, if it is non-empty. This switch value can be bypassed by using Rci_Cmvc."
001c 0129       | )  |		Execute	Any,Make_Visible
001d 0092 004f  |   O|		Action	Push_String_Extended,0x4f					; "This switch applies to all views of target-key "
001f 0129       | )  |		Execute	Any,Make_Visible
0020 0092 0051  |   Q|		Action	Push_String_Extended,0x51					; " that are created within libraries which are associated with this switch-file. Views created under these conditions will have their corresponding remote directories nested within the directory named by this switch value, if it is non-empty. This switch value can be bypassed by using Rci_Cmvc."
0022 0129       | )  |		Execute	Any,Make_Visible
0023 0092 0052  |   R|		Action	Push_String_Extended,0x52					; "If this switch is set to True, the RCI will compile the associated view, but it will not download and compile its units remotely. The default value is False."
0025 0129       | )  |		Execute	Any,Make_Visible
0026 0092 0053  |   S|		Action	Push_String_Extended,0x53					; "This switch contains a string that will be appended to the unit name in the generated remote linker command."
0028 0129       | )  |		Execute	Any,Make_Visible
0029 0092 0054  |   T|		Action	Push_String_Extended,0x54					; "This switch contains a string that will be inserted before the unit name in the generated remote linker command."
002b 0129       | )  |		Execute	Any,Make_Visible
002c 00c4       |    |		Action	Make_Default
002d 00c4       |    |		Action	Make_Default
002e 00c4       |    |		Action	Make_Default
002f 00c4       |    |		Action	Make_Default
0030 00c4       |    |		Action	Make_Default
0031 00c4       |    |		Action	Make_Default
0032 00c4       |    |		Action	Make_Default
0033 00c4       |    |		Action	Make_Default
0034 0092 0055  |   U|		Action	Push_String_Extended,0x55					; "This switch can contain the values \x22interactive\x22 or \x22batch\x22, which will override the default operation mode for compilation within the associated view. If the switch value is anything else, including the null string, the RCI will use the default operation mode (which is determined by the customization or by the >>target key<<.Register command). The default value is the null string."
0036 0129       | )  |		Execute	Any,Make_Visible
0037 c21e       |    |		Store	0x1,0x1e
0038 0092 0056  |   V|		Action	Push_String_Extended,0x56					; "This switch contains the name of the remote RCI program library. The RCI stores this value as part of the state information."
003a 0129       | )  |		Execute	Any,Make_Visible
003b c219       |    |		Store	0x1,0x19
003c 0092 0057  |   W|		Action	Push_String_Extended,0x57					; "If this switch is set to True, the RCI will upload the executable file after a remote link operation is completed successfully. Otherwise the RCI will not retrieve the executable file. The default value is False."
003e 0129       | )  |		Execute	Any,Make_Visible
003f c21b       |    |		Store	0x1,0x1b
0040 0092 0058  |   X|		Action	Push_String_Extended,0x58					; "If this switch is set to True, the RCI will display the text of the remote commands that are executed during coding and linking. It may display other information also, depending on the customization. The default value is False."
0042 0129       | )  |		Execute	Any,Make_Visible
0043 c21a       |    |		Store	0x1,0x1a
0044 0092 0059  |   Y|		Action	Push_String_Extended,0x59					; "If this switch is set to true, coding a unit on the host will cause it to be downloaded to the remote machine only if it has been edited since it was last downloaded. If false units will always be downloaded during coding. The default value is true"
0046 0129       | )  |		Execute	Any,Make_Visible
0047 c21f       |    |		Store	0x1,0x1f
0048 00bf       |    |		Action	Accept_Activation
0049			BODY_0008:
0049 00bc       |    |		Action	Signal_Activated
004a 00bb       |    |		Action	Signal_Completion
004b ; --------------------------------------------------------------------------------------
004b ; STRING TABLE
004b ; --------------------------------------------------------------------------------------
004b 0020       |    |		.STRTAB	0x0020->0x005b							; "If this switch is set to True, the RCI will automatically create the remote directory when you call a CMVC command to create an RCI view. Otherwise no remote directory will be created by a CMVC command. The default value is True."
004c 0103       |    |		.STRTAB	0x0103->0x00cd							; "If this switch is set to True, the RCI will automatically transfer units during the Installed-to-Coded phase in Batch mode. If this switch is False, units will only be transferred during a Build_Script operation if the Transfer_To_Target parameter is set to True. The default value is False."
004d 0224       | $  |		.STRTAB	0x0224->0x015f							; "This switch contains a string that will be appended to the unit name in the generated target compiler command."
004e 0290       |    |		.STRTAB	0x0290->0x0196							; "This switch contains a string that will be inserted before the unit name in the generated target compiler command."
004f 0300       |    |		.STRTAB	0x0300->0x01cf							; "This switch applies to all views of target-key "
0050 032d       | -  |		.STRTAB	0x032d->0x01e6							; " that are created within libraries which are associated with this switch-file. Views created under these conditions will have their corresponding remote directories built on the machine named by this switch value, if it is non-empty. This switch value can be bypassed by using Rci_Cmvc."
0051 0449       | I  |		.STRTAB	0x0449->0x0275							; " that are created within libraries which are associated with this switch-file. Views created under these conditions will have their corresponding remote directories nested within the directory named by this switch value, if it is non-empty. This switch value can be bypassed by using Rci_Cmvc."
0052 056c       | l  |		.STRTAB	0x056c->0x0308							; "If this switch is set to True, the RCI will compile the associated view, but it will not download and compile its units remotely. The default value is False."
0053 0607       |    |		.STRTAB	0x0607->0x0356							; "This switch contains a string that will be appended to the unit name in the generated remote linker command."
0054 0671       | q  |		.STRTAB	0x0671->0x038c							; "This switch contains a string that will be inserted before the unit name in the generated remote linker command."
0055 06df       |    |		.STRTAB	0x06df->0x03c4							; "This switch can contain the values \x22interactive\x22 or \x22batch\x22, which will override the default operation mode for compilation within the associated view. If the switch value is anything else, including the null string, the RCI will use the default operation mode (which is determined by the customization or by the >>target key<<.Register command). The default value is the null string."
0056 085d       | ]  |		.STRTAB	0x085d->0x0484							; "This switch contains the name of the remote RCI program library. The RCI stores this value as part of the state information."
0057 08d7       |    |		.STRTAB	0x08d7->0x04c2							; "If this switch is set to True, the RCI will upload the executable file after a remote link operation is completed successfully. Otherwise the RCI will not retrieve the executable file. The default value is False."
0058 09a9       |    |		.STRTAB	0x09a9->0x052c							; "If this switch is set to True, the RCI will display the text of the remote commands that are executed during coding and linking. It may display other information also, depending on the customization. The default value is False."
0059 0a8a       |    |		.STRTAB	0x0a8a->0x059e							; "If this switch is set to true, coding a unit on the host will cause it to be downloaded to the remote machine only if it has been edited since it was last downloaded. If false units will always be downloaded during coding. The default value is true"
005a 0b80       |    |		.STREND 0x0b80->0x061a
005b 4966 2074  |If t|		.STRTAB_STRINGS
061a 0000 0000  |    |		.BLANK	0000[0x6]
0620 ; --------------------------------------------------------------------------------------
0620 ; Debug Table
0620 ; --------------------------------------------------------------------------------------
0620 0004 000f  |    |		.DEBUG4	0x0004,0x000f,0x21e5,0x0000,0x0001,0x0000
0626 0000 00b0  |    |		.XXX[0x40]
0628 0011 710a  |  q |
062a 0000 00b0  |    |
062c 0000 0000  |    |
062e 0004 bc04  |    |
0630 000f 6d0a  |  m |
0632 0000 00b0  |    |
0634 0000 0000  |    |
0636 000c 9004  |    |
0638 000d 1d0a  |    |
063a 0000 00b0  |    |
063c 0000 0000  |    |
063e 0032 0404  | 2  |
0640 000d 9d0a  |    |
0642 0000 00b0  |    |
0644 0000 0000  |    |
0646 003e 2004  | >  |
0648 047c 0508  | |  |
064a 0023 0583  | #  |
064c 0039 0054  | 9 T|
064e 007a 0093  | z  |
0650 00a3 00b9  |    |
0652 00d2 00e2  |    |
0654 00f2 0108  |    |
0656 0121 013d  | ! =|
0658 0156 019a  | V  |
065a 01aa 01ba  |    |
065c 01ca 01da  |    |
065e 0206 02b7  |    |
0660 02c6 02fa  |    |
0662 0355 03bb  | U  |
0664 03f5 0436  |   6|
0666 0000 0000  |    |		.BLANK	0000[0x19a]