|
DataMuseum.dkPresents historical artifacts from the history of: Rational R1000/400 |
This is an automatic "excavation" of a thematic subset of
See our Wiki for more about Rational R1000/400 Excavated with: AutoArchaeologist - Free & Open Source Software. |
top - download
Length: 5120 (0x1400) Types: Ada Source Notes: 03_class, FILE, R1k_Segment, e3_tag, package Subsystem_Audit, seg_0044c4
└─⟦8527c1e9b⟧ Bits:30000544 8mm tape, Rational 1000, Arrival backup of disks in PAM's R1000 └─ ⟦cfc2e13cd⟧ »Space Info Vol 2« └─⟦this⟧
--| --| @SUMMARY --| Hypertext table of unit status such as cmvc and compilation state. --| --| @DESCRIPTION --| This package creates a abstract document report showing --| information about the status of all units within a view. --| The description of each table column follows : --| --| Unit => Simple name of the unit --| Dir => directory name within the view --| (prefixed with "+" means in units directory --| prefixed with "-" means NOT in units directory --| no prefix means spec view unit) --| Exp => unit is exported (visible in spec view) --| (E means Exported in the spec view, --| S means a spec unit that is not exported, --| B means a body unit) --| Usd => unit is used (spec unit has an Ada dependency) --| CTR => unit is controlled --| CIn => unit is checked in (or is not controlled) --| Lat => unit is latest generation (up to date) (or is not controlled) --| Ins => unit is installed (or coded) --| Cod => unit is coded --| Cmp => spec view and load view unit are compatible --| Jnd => unit is joined to the spec view --| ACL => the ACL for the unit --| --| For each column, "+" means "yes" or "true", --| "-" means "no" or "false", and --| " " means "no" or not applicable. --| --| If the unit exists in both the spec view and the load view, then the --| status of both is shown, spec view first. --| {For example : "+/+", "+/-", "-/+", and "-/-") --| --| @INDICES (Command_Interface) --| with Abstract_Document; package Subsystem_Audit is procedure Report (For_Activity : String := "<SELECTION>"; To_Preview_Object : String := "subsystem_audit"; Response : String := "<PROFILE>"); procedure Add_Report (For_Activity : String := "<SELECTION>"; To_Document : in out Abstract_Document.Handle; Response : String := "<PROFILE>"); procedure Report_Problems_Only (For_Activity : String := "<SELECTION>"; To_Preview_Object : String := "subsystem_audit"; Units_Not_Coded : Boolean := False; Units_Not_Installed : Boolean := True; Units_Not_Controlled : Boolean := True; Units_Out_Of_Date : Boolean := True; Units_Checked_Out : Boolean := True; Spec_Not_In_Spec_View : Boolean := True; Units_Not_Compatible : Boolean := True; Units_Not_In_Units_Directory : Boolean := True; Response : String := "<PROFILE>"); procedure Add_Problem_Report (For_Activity : String := "<SELECTION>"; To_Document : in out Abstract_Document.Handle; Units_Not_Coded : Boolean := False; Units_Not_Installed : Boolean := True; Units_Not_Controlled : Boolean := True; Units_Out_Of_Date : Boolean := True; Units_Checked_Out : Boolean := True; Spec_Not_In_Spec_View : Boolean := True; Units_Not_Compatible : Boolean := True; Units_Not_In_Units_Directory : Boolean := True; Response : String := "<PROFILE>"); end Subsystem_Audit;
nblk1=4 nid=0 hdr6=8 [0x00] rec0=17 rec1=00 rec2=01 rec3=094 [0x01] rec0=1a rec1=00 rec2=02 rec3=012 [0x02] rec0=13 rec1=00 rec2=03 rec3=03a [0x03] rec0=09 rec1=00 rec2=04 rec3=001 tail 0x217001a42815c6462f2bb 0x42a00088462061e03