Length: 4008 (0xfa8) Types: TextFile Notes: R1k Text-file segment
└─⟦8527c1e9b⟧ Bits:30000544 8mm tape, Rational 1000, Arrival backup of disks in PAM's R1000 └─ ⟦cfc2e13cd⟧ »Space Info Vol 2« └─⟦0335a5cbb⟧ └─⟦this⟧
Date : December 15, 1992 at 3:48:42 PM Customer : *** Machine : Ancolie (IRP Mulhouse) [408459] Period : 16-SEP-92 to 15-DEC-92 RATIONAL PREVENTIVE MAINTENANCE CHECKLIST (1) Overall System Health Check ___ Ensure customer has a current FULL backup ___ Review system error logs summary ___ Run 5 minutes disk exerciser ___ Run 1 pass tape exerciser ___ Run Level 2 FRU diagnostics ___ Check +5v DC at R1000 backplane _____v _____v _____v ___ Check 15v DC _______v _______v (Series 200) ___ (2) General System Cleanliness ___ Check/clean main cabinet filters ___ Check/clean disk filters ___ Clean cabinets and tape drive surfaces ___ Clean inside and top of R1000 cabinets where necessary ___ Check all fans for proper operation ___ PM line printer ___ Page Counter _________pages ___ Check/replace ribbon ___ Clean ribbon rollers ___ Clean print band ___ Check for character alignment and print quality ___ Vacuum ribbon lint and paper dust ___ PM tape drive Clean R/W head, tape cleaner, and tape path ___ Clean filters on IOP (Series 100) ___ Clean operations terminals ___ (3) Post PM System Diagnostics ___ Run foreplane test ___ Run full pass of R1000 processor diagnostics ___ Run functional diagnostics ___ Run 01 test on tape drive with full (2400 ft.) tape ___ Run 5 minutes disk exerciser ___ Run 1 minute tape exerciser ___ Run communications test on at least 1 port per 8-port module ___ (4) Complete SAR --- \f Booted Configuration : D_12_6_5 Machine Id = 408459 R1000 Series 400 System Board Part# Serial# Art Rev ECO Level Build Date ---------------------- ------- ---------- -------- ---------- ------------- Sequencer 45 4800 2 4 91/06/19 Field Isolation Unit 44 4818 2 2 91/07/15 IOC 49 4774 3 11 91/07/12 Type 43 4865 2 2 91/08/07 Value 42 4260 1 1 91/02/25 32 MB Memory 47 5038 2 4 91/08/19 ReshA 41 4879 3 13 91/08/19 CMC controller serial number = 774 System Boot Configuration Settings ================================== Maintainance_Mode => False Kernel_Debugger_Auto_Boot => True Kernel_Debugger_Wait_On_Crash => True Kernel_Debugger_Dialout_On_Crash => True Modem_Can_Dialout => False Modem_Can_Answer => False Eedb_Auto_Boot => True Kernel_Auto_Boot => True DISK BAD BLOCK INFORMATION Vol Manufact Retarget Total HDA =========================================== 1 185 0 185 J7496 2 136 0 136 J7500