RATIONAL
PREVENTIVE MAINTENANCE CHECKLIST
(1) Overall System Health Check ___
Ensure customer has a current FULL backup ___
Review system error logs summary ___
Run 5 minutes disk exerciser ___
Run 1 pass tape exerciser ___
Run Level 2 FRU diagnostics ___
Check +5v DC at R1000 backplane _____v _____v _____v ___
Check 15v DC _______v _______v (Series 200) ___
(2) General System Cleanliness ___
Check/clean main cabinet filters ___
Check/clean disk filters ___
Clean cabinets and tape drive surfaces ___
Clean inside and top of R1000 cabinets where necessary ___
Check all fans for proper operation ___
PM line printer ___
Page Counter _________pages ___
Check/replace ribbon ___
Clean ribbon rollers ___
Clean print band ___
Check for character alignment and print quality ___
Vacuum ribbon lint and paper dust ___
PM tape drive
Clean R/W head, tape cleaner, and tape path ___
Clean filters on IOP (Series 100) ___
Clean operations terminals ___
(3) Post PM System Diagnostics ___
Run foreplane test ___
Run full pass of R1000 processor diagnostics ___
Run functional diagnostics ___
Run 01 test on tape drive with full (2400 ft.) tape ___
Run 5 minutes disk exerciser ___
Run 1 minute tape exerciser ___
Run communications test on at least 1 port per 8-port module ___
(4) Complete SAR ---