DataMuseum.dkPresents historical artifacts from the history of: Rational R1000/400 Tapes |
This is an automatic "excavation" of a thematic subset of
See our Wiki for more about Rational R1000/400 Tapes Excavated with: AutoArchaeologist - Free & Open Source Software. |
top - metrics - downloadIndex: T V
Length: 15037 (0x3abd)
Types: TextFile
Names: »V«
└─⟦180fe333a⟧ Bits:30000405 8mm tape, Rational 1000, SW CATALOG, 10_20_0
└─⟦180fe333a⟧ Bits:30000537 8mm tape, Rational 1000, SW Catalog 10_20_0
└─⟦5cb1d1d7f⟧ »DATA«
└─⟦3b1ee7bd8⟧
└─⟦this⟧
with Implementation_Dependencies;
use Implementation_Dependencies;
with Type_Definitions;
use Type_Definitions;
with String_Pkg;
use String_Pkg;
------------------------
package Run_Time_Monitor is
------------------------
--| Overview
--| This is the Run Time Monitor package for the Ada Test and
--| Analysis Tool Set (ATETS). Its purpose is to dynamically record
--| information about the execution of programs written in the
--| Ada language. The Run Time Monitor is common to the following
--| ATETS tools:
--|
--| 1) Path - Path Analyzer
--| 2) AutoPath - Automatic Path Analyzer
--| 3) SMART - Self Metric Analysis and Reporting Tool
--| 4) Profile - Performance Analyzer
--|
--| The Run Time Monitor is implemented as a package that is
--| WITHed and USEd by the Ada program being tested. All WITHs,
--| USEs, and calls to the Run Time Monitor procedures are inserted
--| into the target Ada program by the ATETS Source Instrumenter.
--| The execution data about each Ada program unit that has been
--| instrumented is recorded at runtime in an Execution Log File (ELF).
--|
--| The user must select the recording options to be used at
--| run time by specifying one of the above tools as a runtime
--| parameter. Additionally, the user may specify the name of the
--| log file to be generated during execution of the target Ada
--| program. If no log file name is specified by the user then the
--| default log file name will be <toolname>".LOG". The Run Time
--| Monitor checks for the existance of the logfile and if it exists
--| the user must choose to write over it, append to it or select
--| a new filename.
--|
--| Requires
--| The Ada program to be tested must have been instrumented by
--| the Ada Source Instrumenter to insert "hooks", or calls, to the
--| the Runtime Monitor. Information about each program unit in an
--| instrumented compilation unit must be recorded in the ELF via
--| a call to the procedure Unit_Information prior to execution of
--| the program unit. An Ada program unit is a procedure, function,
--| package, task, or generic.
--| N/A: Errors, Raises, Modifies
-- Version : 5.0
-- Author : Mary Koppes Intermetrcs, Inc.
-- Initial Release : 03/23/85
-- Last Modified : 07/16/85
task Rtm is
--| Overview
--| The Run Time Monitor has been implemented as a task in order
--| to synchronize calls from the instrumented program and prevent
--| interleaving of output to th log file.
----------------------
entry Unit_Information
( --| Defines a compilation unit to the RTM
Compilation_Unit : in Ada_Name;
--| The name of the compilation unit
Breakpoint_Number : in Breakpoint_Number_Range;
--| Total number of break points in the compilation unit
--| assigned by the Source Instrumenter
List_Of_Procedures : in Procedure_List
--| A list of the names of all of the program units in
--| the compilation unit
);
--| Effects
--| Unit_Information is the procedure used to define information about
--| each program unit in a compilation unit. If the program unit is
--| the first program unit to be defined by a call to Unit_Information
--| the user is asked to enter the Tool_Name, Logfile Name and a
--| unique test identification string, if desired. The logfile is
--| opened. The rest of the information is not recorded to the logfile
--| at this time. A unique identifier is created by the Source
--| Instrumenter for each program unit which provides a mechanism for
--| handling overloading of unit names. This procedure defines the
--| correlation between program unit names and program unit ID's
--| assigned by the Source Instrumenter. The information is recorded
--| in the execution log file for later use by the report generators.
--| Requires
--| Each program unit must be previously defined to the Runtime Monitor
--| by a call to this procedure prior to being "entered" or "exited."
--| Raises
--| User_Input_Error
--| N/A: Errors, Modifies
-------------------
entry Entering_Unit
( --| Logs program unit and start time to ELF
Enclosing_Unit : in String_Type;
--| The name of the compilation unit
Unit_Number : in Program_Unit_Number_Range;
--| The Program Unit Number
Unit_Type : in Program_Unit_Type;
--| The type of unit ( procedure, function task generic or package )
Task_Number : in out Task_Type_Activation_Number_Range
--| A unique number assigned by the Runtime Monitor
);
--| Effects
--| Entering_Unit first creates a Unit_Identifier from the
--| four procedure parameters. If the program unit is
--| the first program unit to be entered outside of Package
--| initialization and its UNIT_TYPE is PROCEDURE_TYPE, then
--| it is assumed to be the main program unit.
--| When the main procedure is entered, the Tool_Name, Test ID and
--| the Main procedure name are written to the logfile.
--| For each program unit entered, the Logfile_Key "Unit_START"
--| and the unit ID assigned by the Source Instrumenter (Unit_Identifier)
--| are recorded in the log file by calling the Start_Unit procedure
--| which is part of the Write_Log package.
--| If the unit being entered is a task then if the Task_List has not
--| been created it is and the ID is added to the list. The purpose of
--| this list is to maintain the Task_Type_Activation_Number. This
--| number is initially 1 and each time a task of the same type is
--| added to the Task_List, the activation number is incremented.
--| The Task_Type_Activation_Number is written to the logfile and is
--| used by the ATETS report generators to determine which copy of a
--| task is executing. The IN OUT parameter, Task_Number is also
--| updated to pass back to the calling program.
--| Requires
--| A program unit must be previously defined to the Runtime Monitor
--| via a call to the procedure Unit_Information prior to being "entered."
--| N/A: Raises, Errors, Modifies
------------------
entry Exiting_Unit ( --| Logs program unit and stop time to ELF
Unit_Identifier : in Program_Unit_Unique_Identifier
--| A unique ID assigned by the Source Instrumenter
);
--| Effects
--| Exiting_Unit records to the logfile the Logfile_Key "UNIT_STOP"
--| and the Unit_Identifier assigned by the Source Instrumenter.
--| If Package Initialization is not in progress, then the
--| Unit_Identifier is deleted from the Entered_Unit_List.
--| The main program unit is "held" from exiting until all
--| other program units have terminated. If the unit being is
--| the main program unit then the logfile is closed and if
--| the user has chosen to append to an existing logfile
--| it is done at this time.
--| Requires
--| The program unit must be previously defined to the RTM via a call
--| to the procedure Unit_Information.
--| The program unit must have been previously "entered" via a call to
--| the procedure Entering_Unit prior to being "exited."
--| Raises
--| Unit_Exit_Error
--| N/A: Errors, Modifies
-------------------
entry Breakpoint_At
( --| Process program breakpoint
Unit_Identifier : in Program_Unit_Unique_Identifier;
--| A unique ID assigned by the Source Instrumenter
Breakpoint_Type : in Breakpoint_Types;
--| The type of breakpoint
Current_Breakpoint : in Breakpoint_Number_Range
--| Breakpoint number assigned by Source Instrumenter
);
--| Effects
--| case TOOL_NAME
--| when PATH_TOOL | AUTOPATH_TOOL | SMART_TOOL =>
--| log program unit ID (Unit_ID)
--| log type of breakpoint (Breakpoint_Type)
--| log the current breakpoint number (Current_Breakpoint)
--| when PROFILE_TOOL => null; -- no action for PROFILE
--| when others => null;
--| end case;
--| Requires
--| The program unit must be previously defined to the RTM via a call
--| to the procedure Unit_Information.
--| The program unit must have been previously "entered" via a call to
--| the procedure Entering_Unit.
--| N/A: Raises, Errors, Modifies
-------------------------
entry Put_Call_Parameters (--| Log AutoPath input parameter list to ELF
Call_Parameters : in Input_Parameter_List
--| The user specified input parameter list
);
--| Effects
--| Logs the calling parameter list for a single execution of the
--| unit under test by the AutoPath shell.
--| N/A: Raises, Requires, Modifies, Errors
---------------
entry Put_Value
(--| Logs value of integer variable to the ELF
Unit_Identifier : in Program_Unit_Unique_Identifier;
--| A unique ID assigned by the Source Instrumenter for the current unit
Variable_Name : in String; --| The name of the variable
Integer_Value : in Integer --| The variable's value
);
--| Effects
--| Logs integer values to the execution log file.
--| Puts the program unit, variable name, and current value.
--| N/A: Raises, Requires, Modifies, Errors
---------------
entry Put_Value
(--| Logs value of Long_Integer variable to the ELF
Unit_Identifier : in Program_Unit_Unique_Identifier;
--| A unique ID assigned by the Source Instrumenter for the current unit
Variable_Name : in
String; --| The name of the variable
Long_Integer_Value : in Long_Integer --| The variable's value
);
--| Effects
--| Logs long_integer values to the execution log file.
--| Puts the program unit, variable name, and current value.
--| N/A: Raises, Requires, Modifies, Errors
---------------
entry Put_Value
(--| Logs value of FLOAT variable to the ELF
Unit_Identifier : in Program_Unit_Unique_Identifier;
--| A unique ID assigned by the Source Instrumenter for the current unit
Variable_Name : in String; --| The name of the variable
Float_Value : in Float --| The variable's value
);
--| Effects
--| Logs floating point values to the execution log file
--| Puts the program unit, variable name, and current value
--| N/A: Raises, Requires, Modifies, Errors
---------------
-- Rational Environment note: Long_Float not implemented; following removed -jwb
-- entry Put_Value (--| Logs value of Long_Float variable to the ELF
-- Unit_Identifier : in Program_Unit_Unique_Identifier;
--| A unique ID assigned by the Source Instrumenter for the current unit
-- Variable_Name : in String; --| The name of the variable
-- Long_Float_Value : in Long_Float --| The variable's value
-- );
--| Effects
--| Logs long_float values to the execution log file.
--| Puts the program unit, variable name, and current value.
--| N/A: Raises, Requires, Modifies, Errors
---------------
entry Put_Value
(--| Logs value of string variable to the ELF
Unit_Identifier : in Program_Unit_Unique_Identifier;
--| A unique ID assigned by the Source Instrumenter for the current unit
Variable_Name : in String; --| The name of the variable
String_Value : in String --| The variable's value
);
--| Effects
--| Logs string values to the execution log file
--| Puts the program unit, variable name, and current value
--| This procedure used to log the value of
--| strings
--| characters
--| enumerated data types (including booleans)
--| N/A: Raises, Requires, Modifies, Errors
-----------------
entry Start_Delay
(--| Records a delay for the specified unit and
--| duration in the ELF
Unit_Identifier : in Program_Unit_Unique_Identifier;
--| A unique ID assigned by the Source Instrumenter for the current unit
Seconds : in Duration
--| The length of the delay in seconds
);
--| Effects
--| Records a delay for the specified unit and duration in the
--| Execution Log File. This entry is not called directly by the
--| the instrumented program. It is called by the function
--| Starting_Delay.
--| N/A: Raises, Requires, Modifies, Errors
end Rtm;
-----------------------
function Starting_Delay
(--| Records a delay for the specified unit and
--| duration in the ELF
Unit_Identifier : in Program_Unit_Unique_Identifier;
--| A unique ID assigned by the Source Instrumenter for the current unit
Seconds : in Duration
)
return Duration;
--| Effects
--| Records a delay for the specified unit and duration in the
--| Execution Log File. The length of the Delay is returned to
--| the calling unit. This unit is implemented as a function
--| to enable trapping of delay times in timed entry statements.
--| N/A: Raises, Requires, Modifies, Errors
end Run_Time_Monitor;