DataMuseum.dkPresents historical artifacts from the history of: Rational R1000/400 Tapes |
This is an automatic "excavation" of a thematic subset of
See our Wiki for more about Rational R1000/400 Tapes Excavated with: AutoArchaeologist - Free & Open Source Software. |
top - metrics - downloadIndex: B T
Length: 5780 (0x1694)
Types: TextFile
Names: »B«
└─⟦180fe333a⟧ Bits:30000405 8mm tape, Rational 1000, SW CATALOG, 10_20_0
└─⟦180fe333a⟧ Bits:30000537 8mm tape, Rational 1000, SW Catalog 10_20_0
└─⟦5cb1d1d7f⟧ »DATA«
└─⟦3b1ee7bd8⟧
└─⟦this⟧
with Display_Tools;
with Editor;
with Io;
with Job;
with Lost_Key_Name;
with New_Keys;
with Pipe;
with Step_Tools;
with Training_Names;
with Window_Io;
procedure Process_Keys (Course_Name : String; Release_Name : String) is
package Sio renames Io;
package Raw renames Window_Io.Raw;
procedure Step (Num : Integer := 1) renames Step_Tools.Display_Manager.Step;
procedure Select_Module renames Step_Tools.Display_Manager.Select_Module;
procedure Stop renames Step_Tools.Display_Manager.Stop;
procedure Start (Course_Name : String; Release_Name : String)
renames Step_Tools.Display_Manager.Start;
Retries : Natural := 0;
package Key_Ops is new Pipe.Type_Specific_Operations (Raw.Key);
function "=" (K1, K2 : Raw.Key) return Boolean renames Raw."=";
Key_Pipe : Pipe.Handle;
K : Raw.Key;
Live_File : Sio.File_Type;
Maximum_Idle_Time : Duration := 7200.0; -- 2 hours
task Coupler is
entry Start;
entry Read (The_Key : out Raw.Key);
end Coupler;
task body Coupler is
K : Raw.Key;
begin
select
accept Start;
or
terminate;
end select;
loop
Key_Ops.Read (Key_Pipe, K);
select
accept Read (The_Key : out Raw.Key) do
The_Key := K;
end Read;
or
terminate;
end select;
end loop;
end Coupler;
begin
begin
Sio.Open (Live_File, Sio.In_File,
Training_Names.Live_Job_File_Pathname);
Sio.Close (Live_File);
Editor.Alert;
Sio.Put_Line
(Sio.Standard_Error,
"You already have a running script session. Check your Window Directory.");
Step_Tools.Display_Manager.Stop;
return;
exception
when Sio.Name_Error =>
loop
begin
Sio.Create (Live_File, Sio.Out_File,
Training_Names.Live_Job_File_Pathname);
exit;
exception
when Sio.Use_Error =>
if Retries < 10 then
delay 0.5;
Retries := Retries + 1;
else
Editor.Alert;
Sio.Put_Line
(Sio.Standard_Error,
"Use error on use of Live_Job_Files (LOCKS or ACL). " &
"Please call proctor");
Step_Tools.Display_Manager.Stop;
return;
end if;
end;
end loop;
when others =>
Editor.Alert;
Sio.Put_Line
(Sio.Standard_Error,
"Other error on use of Live_Job_Files (LOCKS). Please call proctor");
Step_Tools.Display_Manager.Stop;
return;
end;
begin
Pipe.Open (Key_Pipe, Pipe.Shared_Read, Lost_Key_Name);
exception
when others =>
Sio.Delete (Live_File);
Editor.Alert;
Sio.Put_Line
(Sio.Standard_Error,
"Key pipe has not been created. Please call proctor");
Step_Tools.Display_Manager.Stop;
return;
end;
Display_Tools.Open_Input;
Display_Tools.Open_Output;
Job.Disconnect;
Start (Course_Name, Release_Name);
-- Start the coupler task once the pipe has been opened
Coupler.Start;
loop
-- Wait here for a key from the pipe; if nothing happens for
-- a duration of max_idle_time, the job self destructs
select
Coupler.Read (K);
or
delay Maximum_Idle_Time;
Sio.Delete (Live_File);
abort Coupler;
Stop;
Display_Tools.Delete_Window;
exit;
end select;
if K = New_Keys.Step_Forward then
Step;
elsif K = New_Keys.Step_Backward then
Step (-1);
elsif K = New_Keys.Step_Many then
Window_Io.Bell (Display_Tools.Output_Window);
-- Display_Tools.Open_Input;
-- Locate (Integer'Value
-- (Display_Tools.Query
-- (Prompt =>
-- "Enter Number of Steps , Negatives Accepted",
-- Line => 15, Column => 1)));
-- Display_Tools.Close_Input;
elsif K = New_Keys.Step_Exact then
Window_Io.Bell (Display_Tools.Output_Window);
-- Display_Tools.Open_Input;
-- Locate (Integer'Value
-- (Display_Tools.Query
-- (Prompt => "Enter Entry Number",
-- Line => 15, Column => 1)));
-- Display_Tools.Close_Input;
elsif K = New_Keys.Menu_Select then
Select_Module;
elsif K = New_Keys.Quit then
Sio.Delete (Live_File);
Stop;
Display_Tools.Delete_Window;
exit;
else
Window_Io.Bell (Display_Tools.Output_Window);
end if;
end loop;
exception
when Step_Tools.Terminate_Script | Step_Tools.Time_Out =>
abort Coupler;
Sio.Delete (Live_File);
Display_Tools.Delete_Window;
when others =>
abort Coupler;
Sio.Delete (Live_File);
Editor.Alert;
Sio.Put_Line
(Sio.Standard_Error,
"Unknown Error (Possibly a Lock on Script_Text File). Please call Proctor.");
Display_Tools.Delete_Window;
end Process_Keys;